User manual HANNA INSTRUMENTS HI 93732N

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93732N. We hope that this HANNA INSTRUMENTS HI 93732N user guide will be useful to you.


HANNA INSTRUMENTS HI 93732N : Download the complete user guide (368 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 93732N (368 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93732N

Detailed instructions for use are in the User's Guide.

[. . . ] This instrument is in compliance with directives. SPECIFICATIONS DISPLAY CODE GUIDE This indicates that the meter is in a ready state and zeroing can be performed. This indicates that the meter is in a zeroed state and measurement can be performed. Insert a sample before adding reagent and press ZERO. PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. Each Ion Specific Meter is supplied complete with · Two Sample Cuvets and Caps · One Transport Cap · One 60 mL glass Bottle with Stopper · 9V Battery Note: Conserve all packing material until the instrument has been observed to function correctly. [. . . ] If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895 , USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. GENERAL DESCRIPTION The HI 93732N meter measures the content of dissolved oxygen (O2) in surface, feed, natural and waste waters in the 0. 0 to 10. 0 mg/L (ppm) range. The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same place every time it is placed into the measurement cell. The amount of reagent is precisely dosed to ensure maximum repeatability. The meter has an auto-shut off feature that will turn itself off after 10 minutes of non-use. Light Emitting Diode @ 470 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater (18th edition), azide modified Winkler method. The reaction between dissolved oxygen and the reagent causes a yellow tint in the sample. Light Life Life of the instrument Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery 1 x 9 volt/40 hours Type/Life Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ). REQUIRED REAGENTS Code HI 93732A-0 HI 93732B-0 HI 93732C-0 Description Reagent A Reagent B Reagent C Reagents for 100 tests Reagents for 300 tests Quantity 5 drops 5 drops 10 drops REAGENT SETS HI 93732-01 HI 93732-03 OPERATIONAL GUIDE MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. · Fill one 60 mL glass bottle completely with the unreacted sample. · Replace the cap and ensure that a small part of the sample spills over. x5 x5 ON OFF · Replace the cap and invert the bottle until dissolution of the settled flocculant is complete. The sample is ready for measurement when it is yellow and completely limpid. · Fill the cuvet up to the mark with 10 mL of the unreacted (original) sample, and replace the cap. · Place the cuvet into the older and ensure that the notch on the cap is positioned securely into the groove. · Press ZERO and "SIP" will appear on the display. ZERO INTERFERENCES Interferences may be caused by reducing and oxidizing materials. ACCESSORIES REAGENT SETS HI 93732-01 Reagents for 100 tests HI 93732-03 Reagents for 300 tests TIPS FOR AN ACCURATE MEASUREMENT The instruction listed below should be carefully followed during testing to ensure best accuracy. · Each time the cuvet is used, the cap must be tightened to the same degree. · Whenever the cuvet is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI 731318 or a lintfree cloth prior to insertion. · Shaking the cuvet can generate bubbles in the sample, causing higher readings. [. . . ] · Reinsert the cuvet into the instrument. BATTERY REPLACEMENT Battery replacement must only take place in a non-hazardous area using a 9V alkaline battery. Detach the battery from the terminals and attach a fresh 9V battery while paying attention to the correct polarity. Replace the battery and the cover. 9V · Press READ and "SIP" will appear during measurement. x 10 Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93732N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93732N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.