User manual HANNA INSTRUMENTS HI 93731

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93731. We hope that this HANNA INSTRUMENTS HI 93731 user guide will be useful to you.


HANNA INSTRUMENTS HI 93731 : Download the complete user guide (305 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 93731 (497 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93731

Detailed instructions for use are in the User's Guide.

[. . . ] directives This instrument is in compliance with EN 50081-1 and EN 50082-1. SPECIFICATIONS DISPLAY CODE GUIDE This indicates that the meter is in a ready state and zeroing can be performed. This indicates that the meter is in a zeroed state and measurement can be performed. A blinking "0. 00" indicates that the sample absorbs less light than the zero reference. [. . . ] If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895 , USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. The HI 93731 meter measures the zinc content in water and wastewater in the 0. 00 to 3. 00 mg/L (ppm) range. The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same place every time it is placed into the measurement cell. The reagents are in liquid and powder form and are supplied in bottles and in packets. The amount of reagent is precisely dosed to ensure maximum repeatability. The meters have an auto-shut off feature that will turn the instrument off after 10 minutes of non-use. Light Emitting Diode @ 585 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18 t h edition, Zincon method. The reaction between zinc and the reagent causes a brownish-green to a blue tint in the sample Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery Type/Life 1 x 9 volt/40 hours Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ). V REQUIRED REAGENTS Code HI 93731A-0 HI 93731B-0 Description Reagent A Reagent B Quantity 1 packet 0. 5 mL REAGENT SETS HI 93731-01 Reagents for 100 tests HI 93731-03 Reagents for 300 tests OPERATIONAL GUIDE MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. ON OFF · Wait for a few seconds and the display will show "-0. 0-". This will be the sample. TIPS FOR AN ACCURATE MEASUREMENT The instruction listed below should be carefully followed during testing to ensure best accuracy. · In order to maintain the same conditions during the zeroing and the measuring phases, it is necessary to close the cuvet to prevent any contamination. · Do not let the test sample stand too long after reagent is added or accuracy will be lost. · Whenever the cuvet is placed into the measurement cell, it must be completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI 731318 or a lint-free cloth prior to insertion. · It is possible to take multiple readings in a row, but it is recommended that a zero reading be taken for each sample and that the same cuvet is used for zeroing and measurement. · It is important to discard the sample immediately after the reading is taken because the glass might become permanently stained. [. . . ] Detach the battery from the terminals and attach a fresh 9V battery while paying attention to the correct polarity. Replace the battery and the cover. 9V INTERFERENCES Interference may be caused by: Aluminum above 6 mg/L Cadmium above 0. 5 mg/L Copper above 5 mg/L Iron above 7 mg/L Manganese above 5 mg/L Nickel above 5 mg/L Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93731




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93731 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.