User manual HANNA INSTRUMENTS HI 93720

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93720. We hope that this HANNA INSTRUMENTS HI 93720 user guide will be useful to you.


HANNA INSTRUMENTS HI 93720 : Download the complete user guide (296 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93720

Detailed instructions for use are in the User's Guide.

[. . . ] This manual will provide you with the necessary information for the correct operation of the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. directives This instrument is in compliance with EN 50081-1 and EN 50082-1. SPECIFICATIONS DISPLAY CODE GUIDE This indicates that the meter is in a ready state and zeroing can be performed. This indicates that the meter is in a zeroed state and measurement can be performed. [. . . ] When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895 , USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. The HI 93720 meter measures the calcium hardness content, as CaCO3, in water and wastewater in the 0. 00 to 2. 70 mg/L (ppm) range. The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same place every time it is placed into the measurement cell. The amount of reagent is precisely dosed to ensure maximum repeatability. The meters have an auto-shut off feature that will turn the instrument off after 10 minutes of non-use. Light Emitting Diode @ 555 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, calmagite method. The reaction between Ca and reagents causes a red tint in the sample Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery Type/Life 1 x 9 volt/40 hours Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ). REQUIRED REAGENTS Code HI 93720A-0 HI 93720B-0 HI 93720C-0 Description Ca indicator Alkali solution EGTA solution Quantity 0. 5 mL 0. 5 mL 1 drop V REAGENT SETS HI 93720-01 Reagents for 100 tests HI 93720-03 Reagents for 300 tests OPERATIONAL GUIDE MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. · Add 0. 5 mL of HI 93720A Calcium indicator solution, then swirl to mix. · Add 0. 5 mL of HI 93720B Alkali solution for Calcium, then swirl to mix. B ON OFF · Remove the buffered blank and insert the second cuvet into the instrument, making sure that the notch on the cap is positioned securely into the groove. "SIP" will appear during measurement. READ TIMED INTERFERENCES Interference may be caused by excessive amounts of heavy metals. ACCESSORIES REAGENT SETS HI 93720-01 Reagents for 100 tests HI 93720-03 Reagents for 300 tests TIPS FOR AN ACCURATE MEASUREMENT The instruction listed below should be carefully followed during testing to ensure best accuracy. · In order to maintain the same conditions during the zeroing and the measuring phases, it is necessary to close the cuvet to prevent any contamination. · Do not let the test sample stand too long after reagent is added or accuracy will be lost. · Whenever the cuvet is placed into the measurement cell, it must be completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI 731318 or a lint-free cloth prior to insertion. · It is possible to take multiple readings in a row, but it is recommended that a zero reading be taken for each sample and that the same cuvet is used for zeroing and measurement. · It is important to discard the sample immediately after the reading is taken because the glass might become permanently stained. · Shaking the cuvet can generate bubbles in the sample, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the vial. · All the reaction times reported in this manual are referred to 20°C (68°F). [. . . ] For your reference, factors to convert readings in mg/L to French degrees (FD), German degrees (DD) and English degrees (ED) of hardness are as follows: 1 mg/L = 0. 1 FD = 0. 056 DD = 0. 07 ED. CE DECLARATION OF CONFORMITY BATTERY REPLACEMENT Battery replacement must only take place in a non-hazardous area using a 9V alkaline battery. Detach the battery from the terminals and attach a fresh 9V battery while paying attention to the correct polarity. Replace the battery and the cover. Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93720




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93720 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.