User manual HANNA INSTRUMENTS HI 93704

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93704. We hope that this HANNA INSTRUMENTS HI 93704 user guide will be useful to you.


HANNA INSTRUMENTS HI 93704 : Download the complete user guide (1313 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 93704 (505 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93704

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 93704 Hydrazine ISM Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct operation of the meter. [. . . ] If the cover is properly installed, then contact your dealer or the nearest Hanna Customer Service Center. If this is not the case, contact your dealer or the nearest Hanna Customer Service Center. The "V" indicates that the battery voltage is getting low and the battery needs to be replaced. Change the battery to restart. PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. Each Ion Specific Meter is supplied complete with · 9V Battery · Two Sample Cuvets and Caps · One Transport Cap Note: Conserve all packing material until the instrument has been observed to function correctly. Any defective item must be returned in its original packing. SPECIFICATIONS Range Resolution Accuracy Typical EMC Deviation Light Source Method 0 to 400 µg/L 1 µg/L ±3% of full scale ±2 µg/L www. hannainst. com This Instrument is in Compliance with the CE Directives GENERAL DESCRIPTION WARRANTY HI 93704 is warranted for two years against defects in workmanship and materials when used for its intended purpose and maintained according to instructions. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. [. . . ] The meters have an auto-shut off feature that will turn the instrument off after 10 minutes of non-use. Light Emitting Diode @ 470 nm Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88 for natural and treated water. The reaction between hydrazine and the liquid reagent causes a yellow tint in the sample Light Life Life of the instrument Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery Type/Life 1 x 9 volt/40 hours Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ). V REQUIRED REAGENT Code HI 93704-0 Description Liquid Reagent Quantity 2x12 drops REAGENT SETS HI 93704-01 Reagents for 100 tests HI 93704-03 Reagents for 300 tests [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93704




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93704 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.