User manual HANNA INSTRUMENTS HI 93700

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93700. We hope that this HANNA INSTRUMENTS HI 93700 user guide will be useful to you.


HANNA INSTRUMENTS HI 93700 : Download the complete user guide (406 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 93700 (405 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 93700

Detailed instructions for use are in the User's Guide.

[. . . ] This instrument is in compliance with directives EN 50081-1 and EN 50082-1. SPECIFICATIONS DISPLAY CODE GUIDE This indicates that the meter is in a ready state and zeroing can be performed. This indicates that the meter is in a zeroed state and measurement can be performed. A blinking "0. 00" indicates that the sample absorbs less light than the zero reference. [. . . ] If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895 , USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. The HI 93700 meter measures the ammonia nitrogen (NH3-N) content in water, wastewater and seawater in the 0. 00 to 3. 00 mg/L (ppm) range. The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same place every time it is placed into the measurement cell. The amount of reagent is precisely dosed to ensure maximum repeatability. The meters have an auto-shut off feature that will turn the instrument off after 10 minutes of non-use. Light Emitting Diode @ 470 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method. The reaction between ammonia and reagents causes a yellow tint in the sample. Light Life Life of the instrument Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery Type/Life 1 x 9 volt/40 hours Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ). REQUIRED REAGENTS Code HI 93700A-0 HI 93700B-0 Description First Reagent Second Reagent Quantity 4 drops (6 drops in seawater) 4 drops (10 drops in seawater) The "V" indicates that the battery voltage is getting low and the battery needs to be replaced. Change the battery to restart. REAGENT SETS HI 93700-01 Reagents for 100 tests HI 93700-03 Reagents for 300 tests OPERATIONAL GUIDE MEASUREMENT PROCEDURE · Turn the meter on by pressing ON/OFF. · Fill the cuvet up to 1. 5 cm (¾") below the rim with 10 mL of unreacted sample, and replace the cap. · Place the cuvet into the holder and ensure that the notch on the cap is positioned securely into the groove. · Press ZERO and "SIP" will appear on the display. ZERO · Add 4 drops of the Second reagent (10 drops in case of seawater analysis). ON OFF TIPS FOR AN ACCURATE MEASUREMENT The instruction listed below should be carefully followed during testing to ensure best accuracy. · In order to maintain the same conditions during the zeroing and the measuring phases, it is necessary to close the cuvet to prevent any contamination. · Do not let the test sample stand too long after reagent is added or accuracy will be lost. · Whenever the cuvet is placed into the measurement cell, it must be completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI 731318 or a lint-free cloth prior to insertion. [. . . ] Detach the battery from the terminals and attach a fresh 9V battery while paying attention to the correct polarity. Replace the battery and the cover. 9V · Add 4 drops of the First reagent (6 drops in case of seawater analysis). · Replace the cap and swirl the solution. Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93700




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 93700 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.