User manual HANNA INSTRUMENTS HI 935006

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 935006. We hope that this HANNA INSTRUMENTS HI 935006 user guide will be useful to you.


HANNA INSTRUMENTS HI 935006 : Download the complete user guide (398 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 935006

Detailed instructions for use are in the User's Guide.

[. . . ] 10 Functional Description and Specifications of HI 935007 . . . . . . . . . . . . . . . . . . . . 27 2 K-THERMOCOUP THERMOMETER LE MR ON OFF HI MEMHOLD LO °C °F HI 93531 http://www. hannainst. com These Instruments are in Compliance with the CE Directives mank93r4. p65 3 4 PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. Each thermometer comes supplied with a 9V battery and instruction manual. Note: Save all packing material until you are sure that the instrument functions correctly. [. . . ] for one year, excluding probe error ±3°C ±6°F K, J and T thermocouple(optional) (for K-thermocouple see pages 22-25) 9V/100 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) Resolution Accuracy Typical EMC Deviation Probe Battery Environment Dimensions Weight 7 8 mank93r4. p65 9 10 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 935005 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 935006 ins rum n s °C ins rum n s 1 °C 1 RANGE: -80. 0°C to +400°C K-THERMOCOUPLE THERMOMETER 7 CLEAR ON OFF 2 ON OFF 2 6 HI HOLD 3 5 HI 935005 LO °C °F 4 Foodcare RANGE: -50°C to +950°C HI 935006 1. HI/LO Temperature erasing key. Specifications Low Range High Range Resolution -50. 0 to 150. 0°C -58. 0 to 199. 9°F / 200 to 302ºF -50 to 950°C -58 to 1742°F 0. 1°C (-50. 0 to 150. 0°C) 1°C (-50 to 950°C) 0. 2°F (-58. 0 to 199. 9°F) 1°F (-58 to 1742°F) ±0. 4ºC (low range ºC) ±0. 8ºF (low range ºF) ±0. 2% f. s. (high range ºC/ºF) ±3°C ±6°F K-thermocouple (pag. 22-25) 9V/500 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) 1. ON/OFF Key. Specifications Range Resolution Accuracy Typical EMC Deviation Probe Battery Environment Dimensions Weight -80. 0 to 120. 0°C 121 to 400°C 0. 1°C (-50. 0 to 120. 0°C) 1°C (120 to 400°C) ±0. 3% for one year, excluding probe error ±3°C T-thermocouple (optional) 9V/500 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) Accuracy Typical EMC Dev. Probe (optional) Battery Environment Dimensions Weight 9 10 mank93r4. p65 11 12 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 935007 OPERATIONAL GUIDE INITIAL PREPARATION Remove the battery cover on the rear of your thermometer, unwrap the battery and connect it to the clip. Insert the battery in its compartment and replace the cover. 9 VOLT BATTERY Battery Compartment SLIDE OFF To switch on, press ON/OFF on the front of the unit. ON OFF 1. Measuring Scale Key (°C or °F). Specifications Low Range High Range Resolution -50. 0 to 150. 0°C -58. 0 to 199. 9°F / 200 to 302ºF -50 to 950°C -58 to 1742°F 0. 1°C (-50. 0 to 150. 0°C) 1°C (-50 to 950°C) 0. 2°F (-58. 0 to 199. 9°F) 1°F (-58 to 1742°F) ±0. 4ºC (low range ºC) ±0. 8ºF (low range ºF) ±0. 2% f. s. (high range ºC/ºF) ±3°C ±6°F HI766C K-thermocouple 9V/500 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) Your thermometer will carry out a self diagnostic test. The LCD shows all the segments at once, to make sure none is missing. BAT HOLD KJT ºC ºF HI LO After the test, the thermometer will switch to the measurement mode. If a temperature probe is plugged in, the unit will display the temperature. For HI 93530, HI93531, HI 93532, HI 93551 If the probe is not plugged in, the display will show "----". For HI 935005 and HI 935006 If the probe is not plugged in, the display will show "Er". To switch your thermometer off, press ON/OFF again. Accuracy Typical EMC Dev. Probe (included) Battery Environment Dimensions Weight ON OFF 11 12 mank93r4. p65 13 14 MEASURING SCALE (°C/°F)(for HI93530, HI93531, HI93551, HI935005, HI935007 only) When the meter is turned on, it automatically defaults to the °C scale. Measurements can be performed on either the Centigrade or the Fahrenheit scale. To change the scale, press °C/°F once. HOLD MODE (for HI93530, HI93551 and HI 935005 only) The reading hold function is activated by the HOLD key. For HI 93530 and HI 93551 only To freeze the measured temperature on the display, press and hold the HOLD key. "HOLD" is displayed when this key is pressed. °C °F °F HOLD HOLD MEASUREMENT RESOLUTION When switched on, HI93530, HI 93531, HI 93532 and HI 93551 default to a 0. 1 digit resolution (see specifications). These instruments automatically change the resolution to 1 degree when the measured temperature is higher than 999. 9°C (or 120°C for HI935006). For HI 935005 and HI935007 only When switched on, HI 935005 and HI935007 default to 1 d e g r e e resolution. Press ON/OFF again to change the resolution to 0. 1°C or 0. 2°F. ON OFF °C °C As soon as the HOLD key is released, the meter returns to the normal operational mode. For HI 935005 only The temperature is frozen on the display until the HOLD button is pressed a second time. [. . . ] If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. HI 766F High temperature wire probe without handle, max 1100°C/2000°F 255mm 10" 1. 5mm 0. 06" HI 766F1 Flexible probe without handle, max 480°C/900°F 2mm 0. 08" 1m 3. 3' HI 766TV1 Pipe clamp probe, max 200°C/390°F 35mm Max. 1. 4" Other accessories: HI 710004 Soft carrying case measuring 150x90x30mm HI 710007 Blue rubber boot measuring 155 x 90 x 45 mm HI 710008 Orange rubber boot measuring 155 x 90 x 45 mm HI 710031 Rugged carrying case MANK93R4 Instruction manual 25 All rights are reserved. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 935006




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 935006 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.