User manual HANNA INSTRUMENTS HI 935002

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 935002. We hope that this HANNA INSTRUMENTS HI 935002 user guide will be useful to you.


HANNA INSTRUMENTS HI 935002 : Download the complete user guide (543 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 935002 (740 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 935002

Detailed instructions for use are in the User's Guide.

[. . . ] When shipping any instrument, make sure it is properly packaged for complete protection. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 OPERATIONAL GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 USER CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] CAL (HI 935005N only) : press and hold for 5 seconds to enter the Calibration mode (with reading within ±3°C range); press to abort the Calibration mode. 5 SPECIFICATIONS OF HI 935002 & HI 935009 SPECIFICATIONS -50. 0 to 199. 9°C / 200 to 1350°C -58. 0 to 399. 9°F / 400 to 2462°F 0. 1°C (up to 199. 9°C) / 1°C (outside) 0. 1°F (up to 399. 9°F) / 1°F (outside) ±0. 2% full scale for one year, excluding probe error ± 3°C / ± 6°F with HI 766 K-thermocouple probe 3x1. 5V AA (IEC LR6) batteries, approx. 1600 hours of continuous use (BL off) user selectable: 8 min, 60 min, disabled -10 to 50°C (14 to 122°F); RH 100% 150 x 80 x 36 mm (5. 9 x 3. 1 x 1. 4") 235 g (8. 3 oz. ) Range (*) Resolution Accuracy (@20°C/68°F) Typical EMC Deviation Battery Auto-off (HI 935009 only) Environment Dimensions Weight (*) Range may be limited by probe. Main features: · · · · · · · · · · · · · Two independent measurement channels, T1 and T2 HI 766 K-thermocouple probes Display of temperature in degrees Celsius or Fahrenheit Range -50 to 1350°C or -58 to 2462°F HOLD function HI and LO (Max and Min) temperature values always displayed on the LCD DISP function to select the information to be displayed (Normal, Relative or T1/T2) Remaining battery life indication / low battery detection Waterproof casing Auto-off capability (HI 935009 only) MR function for recalling memorized reading (HI 935009 only) Backlight feature (HI 935009 only) User calibration at 0°C (HI 935009 only) 6 HI 935002 HI 935009 Keyboard Functions: ON/OFF : turn the meter ON and OFF. ALT (HI 935009 only) : enable the second function keys; the "ALT" tag turns on to indicate that the second functions are enabled. Note: The ALT key can be released before pressing the second function key for 1-hand operation. ALT/ CAL : press and hold for about 5 seconds to enter the Calibration mode (with reading within ±3°C range). (ALT +) BL : toggle the backlight ON and OFF. 7 OPERATIONAL GUIDE To switch the instrument ON, press the ON/OFF key. The thermometer will carry out a self diagnostic test routine, the LCD will show all segments for a few seconds (or as long as ON/OFF is held), followed by the percentage indication of the remaining battery life. The thermometer then enters normal measurement mode. If a temperature probe is plugged in, the meter displays the measured temperature. If no probe is plugged in, or if the reading is over-range, the display shows flashing dashes. If a measurement is slightly over the range of the meter specifications, the display will flash the closest full-scale value. To switch the meter OFF, press the ON/OFF key. °C/°F SELECTION Measurements can be displayed in either degrees Celsius or Fahrenheit. The meter is factory set to °C scale; to change the scale, press °C/°F key or (ALT+) °C/°F keys, HI 935005 / 5005N HI 935009 or set the switch located in the battery compartment (HI 935002 only, see figure on page 10). HOLD and MR FUNCTIONS The HOLD function is activated by pressing the HOLD key. The measured temperature is held on the display until HOLD is pressed again. The "HOLD" tag blinks on the display while in 8 HOLD mode. Note: Although the display is frozen, internally the meter continues measuring and updating Hi/Lo and relative values. In HI 935009 only, the held value is also stored in non-volatile memory and can be recalled by pressing (ALT+) MR key. While the MR key is held, the "HOLD" tag lights up and the meter displays the stored value; when the MR key is released, after 1 second the meter returns to normal measurement mode. HIGH/LOW TEMPERATURES The maximum and minimum temperatures are continuously monitored and displayed on the lower portion of the LCD. Note: When the reading goes over-range or the probe is removed, the Hi and Lo values display dashes until cleared. CLEAR FUNCTION Upon pressing the CLR key, the High/Low values may be cleared at any time during measurement and the current reading is assigned to the highest and lowest temperature values for the displayed channel only. AUTO SHUT-OFF (HI 935005 and HI 935009) To save battery life, the HI 935005 and HI 935009 models are provided with an auto-off feature, which switches the instrument off after a certain period of nonuse. The delay time can be changed by the user (8 minutes, 60 minutes, or disabled). To access this feature, the HI 935005 is provided with an internal button located in the battery compartment (see figure on page 10). [. . . ] · Prepare an ice bath with approximately equal volumes of distilled water and chopped ice made from distilled water. · Immerse the temperature probe in the center of the ice bath, taking care not to touch the ice with the probe tip. · Ensure that the meter is measuring a temperature within ±3°C. · To enter the Calibration mode, press and hold the CAL button for about 5 seconds. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 935002




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 935002 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.