User manual HANNA INSTRUMENTS HI 931002

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 931002. We hope that this HANNA INSTRUMENTS HI 931002 user guide will be useful to you.


HANNA INSTRUMENTS HI 931002 : Download the complete user guide (359 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 931002

Detailed instructions for use are in the User's Guide.

[. . . ] 9 BATTERY REPLACEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 FUSE REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 1) 2) 3) 4) 5) LCD display Mode selection switch coarse setting knob Unit selection key ON/OFF key 6) 7) 8) 9) 10) fine setting knob Ext. power adapter socket "A" connector "P" connector "Com. " connector. · Switch the selection switch to the "Drive" mode. Range Active Drive Passive Drive Active Measure Passive Measure Resolution Accuracy (@20°C/68°F) EMC Typical Deviation Input resistance Fuse Battery Type/Life Ext. Power Supply Environment Dimensions Weight 2. 00 to 19. 99 mA -1. 50 to 14. 00 pH 2. 00 to 19. 99 mA -1. 50 to 14. 00 pH 0. 00 to 19. 99 mA -3. 50 to 14. 00 pH 0. 00 to 19. 99 mA -3. 50 to 14. 00 pH 0. 01mA 0. 01 pH ±0. 01mA ±0. 01 pH ±1% f. s. 20 5x20 mm, 200mA, 250V 9V alkaline/1600 hours of continuous use 12 to 32 VDC 0 to 50°C (32 to 122°F); 95% RH 180 x 83 x 40 mm (7. 1 x 3. 3 x 1. 6") 320 g (11. 3 oz. ) 4 · Wire the calibrator "Com. " and "P" connectors to the Device Under Test (D. U. T. ) input contacts (see page 4, #10 and #9 respectively) using the cables provided, paying attention to the polarity ("Com. " to - and "P" to + terminals). · Turn the Fine and Coarse knobs to any desired value and make sure that the D. U. T. reflects the current value displayed on the HI 931002 LCD. · Calibrate the D. U. T. according to manufacturer instructions if necessary. 5 ACTIVE DRIVE (SIMULATOR) MODE This mode is intended to drive a chart recorder, calibrate a pressure/ current transducer or a current indicator. The HI 931002 supplies a voltage to the 4-20 mA bus via an external connected 12-32 VDC power supply. The calibrator regulates the current, displayed on the LCD, as in the previous mode (Passive Drive). · Connect the external power adapter to the power socket on the right side of the HI 931002. · Wire the calibrator "Com. " and "A" connectors to the Device Under Test (D. U. T. ) input contacts (see page 4, #10 and #8 respectively) using the cables provided, paying attention to the polarity ("Com. " to - and "A" to + terminals). · Turn the Fine and Coarse knobs to any desired value and make sure that the D. U. T. reflects the current value displayed on the HI 931002 LCD. PASSIVE MEASURING (TESTER) MODE This mode is intended to test an active transmitter. The HI 931002 reads the current produced by the transmitter via the 4-20 mA bus and displays the reading in mA or pH units. · Disconnect the external power adapter from HI 931002 if present. · Turn the meter on by pressing the ON/OFF key. · Switch the selection switch to the "Measure" mode. · Wire the calibrator "Com. " and "P" connectors to the Device Under Test (D. U. T. ) input contacts (see page 4, #10 and #9 respectively) using the cables provided, paying attention to the polarity ("Com. " to - and "P" to + terminals). IMPORTANT NOTE: Set the selection switch to MEASURE mode only if the D. U. T. WRONG OPERATION WILL BREAK THE INTERNAL FUSE. · Calibrate the D. U. T. Calibrator operational mode is functional even without a battery or if battery is discharged. 6 7 ACTIVE MEASURING (TESTER) MODE This mode is intended to test a passive transmitter. The HI 931002 supplies only the power to the 4-20 mA bus via an external connected 12-32 VDC power supply and displays the value of the current produced by the transmitter. · Switch the selection switch to the "Measure" mode. mA - pH RELATION The HI 931002 LCD will show the current from the transmitter in mA or in pH units according to the relation: 4 mA = 0 pH 12 mA = 7 pH mA = 1. 14 x (pH reading) + 4 20 mA = 14 pH. [. . . ] If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Customer Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 931002




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 931002 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.