If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9224. We hope that this HANNA INSTRUMENTS HI 9224 user guide will be useful to you.
Manual abstract: user guide HANNA INSTRUMENTS HI 9224
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
HI9224 - HI92240
Portable Microprocessor Printing and Logging pH Meters
instru m
n e ts
pH
MICR pH M OPROC ETER ESSO R PR INTI
HI 92
24
NG
ON/O FF
PAP E
R
CAL
CFM
BUF F
RAN
GE
PRIN T
LOG
http://www. hannainst. com
This Instrument is in Compliance with the CE Directives
Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with directives EN 500811 and EN 50082-1.
TABLE OF CONTENTS
PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Set the appropriate logging interval (see Operational Guide section on page 8). Press the ALT and the LOG keys simultaneously to enter the logging mode. The log number and page number will appear for a few seconds on the display to indicate the current operational mode. The instrument will print a complete set of data and the "LOG" symbol will appear on the bottom left hand-side of the LCD.
ALT
CAL
CON
LOG
Log number
Page number
RANGE
TIME
LOG
The printout provides the following information: a - Date (DD-MM-YY) b - A running log number c - A running sample number (in that particular log) d - Printing interval indicator in minutes 01-07-95 ==01== *0001M b e - time (HH-MM) 0001 11. 01 c 7. 06 pH 17. 5 °C f - pH value g - temperature value
19
a d e f g
To log without printing press the ALT and the PAPER keys at the same time and the "LOG" symbol on display will start to blink. Press ALT and PAPER again to resume logging with printing.
PRINT
PAPER
LOG
ALT
CAL
After approximately 5 minutes the display will switch off but the logging function remains active. While logging, during the sleep mode, the display will periodically flash on. This is a normal indication that the meter is in the logging mode and is currently logging readings. Exit the logging mode first (pressing the ALT ALT and the LOG keys) before setting the RANGE new interval. Note If the PRINT key is pressed while in logging mode, a printout is produced without affecting the running sample number.
RANGE
CAL
CON
TIME
LOG
PRINT
SAMPLE NUMBER
During logging it is possible to know the running sample number. Press the LOG key twice and the display will show the number of values that have been taken since the start of the current log.
LOG
LOGGING MODE WITH PRINTING
This function is suggested when an immediate report of the measurement is required in addition to the recording of the data into memory. Press the ALT and the LOG key simultaneously to enter the logging mode. The log CAL CON ALT number and page number will appear for a few seconds on the display to indicate the RANGE TIME LOG correct operational mode. The printer will
20
print a complete set of data and the "LOG" symbol will appear on the bottom left hand side of the display. During printing, the display shows the time, interval and the "LOG" symbol.
LOG
To reactivate the display press the RANGE key. The printout provides the following information: a - Date (DD-MM-YY) b - A running log number c - A running sample number (in that particular log) d - Printing interval indicator in minutes 01-07-95 e - Time (HH-MM) ==01== *0001M b 0001 11. 01 c 7. 06 pH f - pH value 17. 5 °C g - Temperature value
RANGE
a d e f g
It is always possible to switch from the logging with printing function to the logging function. Press the ALT and the PAPER keys at the same time and the "LOG" symbol will start to blink to indicate that the data is now stored only into memory.
PRINT
PAPER
ALT
CAL
Notes: · It is recommended to use the adapter during logging in printing mode, especially when many printouts are going to be taken. · Before proceeding with logging with printing, make sure there is enough paper for your measurements. When the paper is finished the meter will not advise the operator and the printouts could be lost. If this happens, data will continue to be stored in memory, and it is always possible to print the
21
data at different time (see above). · It is possible to insert a new paper roll during logging session (see page 27) · Once in the logging mode, the interval cannot be changed. Exit the logging mode first (pressing the ALT and the LOG keys) before setting the new interval. · If the PRINT key is pressed while in logging mode, a printout is produced without affecting the running sample number. [. . . ] Use: general purpose.
12 mm 0. 5"
HI 1332
120 mm 4. 7"
"S" VERSION
FC 100B Plastic-body (Kynar®), double junction, refillable, combination pH electrode. Use: general purpose for food industry.
12 mm 0. 5" FC 100
120 mm 4. 7"
FC 200B Plastic-body (Kynar®), open junction, conic, Viscolene, non-refillable, combination pH electrode. Use: meat & cheese.
6 mm 0. 25"
FC 200
75 mm 2. 95"
FC 210B Glass-body, double junction, conic, Viscolene, non-refillable, combination pH electrode. Use: milk, yogurt.
12 mm 0. 5"
FC 210 120 mm 4. 7"
FC 220B Glass-body, triple-ceramic, single junction, refillable, combination pH electrode. [. . . ]