If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9214. We hope that this HANNA INSTRUMENTS HI 9214 user guide will be useful to you.


HANNA INSTRUMENTS HI 9214 : Download the complete user guide (366 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 9214 (474 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9214

Detailed instructions for use are in the User's Guide.

[. . . ] This instrument is in compliance with the directives. FUNCTIONAL DESCRIPTION SPECIFICATIONS Range -2. 00 to 16. 00 pH / -5. 0 to 70. 0 °C Resolution 0. 01 pH / 0. 1 °C Accuracy (@20°C/68°F) ±0. 02 pH / ±0. 5 °C Typical EMC Deviation ±0. 02 pH / ±0. 4°C pH Calibration Automatic, at 1 or 2 points with 3 memorized buffer values Temperature Compensation Automatic Probe HI 12170 pH/temperature probe with screw-type connector Battery Type 1 x 9V alkaline Battery Life 700 hours of continuous use Auto-off after 8 minutes of nonuse Environment 0 to 50°C (32 to 122°F); max 95% RH not condensing Dimensions 185 x 42 x 26 mm (7. 3 x 1. 6 x 1. 0") Weight 350 g (12. 3 oz. ) PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. Note: Conserve all packing material until the instrument has been observed to function correctly. Any defective item must be returned in its original packing. This Instrument is in w w w . c o m Compliance with the CE Directives WARRANTY All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. [. . . ] Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895 , USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. OPERATIONAL GUIDE · The meter is supplied complete with a 9V battery. Remove the battery compartment cover on the back of the meter, install the battery while paying attention to its polarity. · Always remove the electrode protective cap before taking any measurements. If the electrode has been left dry, soak the tip in HI 70300 Storage Solution for half an hour to reactivate it. · Connect the pH electrode to the screw type connector on the meter. Be sure that the electrode and the meter connections are clean and dry to ensure a positive contact. Turn the meter on by pressing ON/OFF. Note: After use, rinse the electrode with water to minimize contamination and store it with a few drops of storage (HI 70300) or pH7 (HI 7007) solution in the protective cap. Note: Always turn the meter OFF and replace the electrode protective cap after use. NEVER USE DISTILLED OR DEIONIZED WATER FOR STORAGE PURPOSES. pH CALIBRATION · Connect the electrode and switch the meter ON. · For a single-point calibration, place the electrode in any buffer, eg. · When the pH tag stops blinking, press the SET/HOLD button to confirm the calibration point. Note: If the pH 7. 01 buffer was used, press the SET/HOLD button again to exit the Calibration mode; the first calibration point is stored and the meter returns to the measurement mode. Otherwise, if a different buffer was used, the meter will automatically return to normal mode. · For a two-point calibration, place the electrode in pH 7. 01 buffer. · When the pH tag stops blinking, press the SET/HOLD button to confirm and store the first calibration point. · When also this buffer is recognized (the pH tag stops blinking), press the SET/HOLD button to confirm and store the second calibration point; the meter will return to normal mode. Note: If a solution with wrong pH value is used as buffer for calibration, the LCD will display the "Ec" message. Note: To reset to the default values, after entering the Calibration mode and before the first calibration point is confirmed (pH tag is blinking), press and hold the SET/ HOLD key, and then press the CAL button. The meter displays "CLr" for a few seconds and then return to normal mode. [. . . ] The meter is also provided with BEPS (Battery Error Preventing System), which avoids any erroneous reading due to low battery level by warning the user with the "Eb" message on the LCD and switching the meter off when the battery is completely rundown. Remove the cover on the back of the meter and replace the battery with a new one, while paying attention to its polarity. Replacement must only take place in a nonhazardous area using an alkaline 9V battery. Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which they are used. Operation of this instrument in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9214




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9214 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.