User manual HANNA INSTRUMENTS HI 91541

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 91541. We hope that this HANNA INSTRUMENTS HI 91541 user guide will be useful to you.


HANNA INSTRUMENTS HI 91541 : Download the complete user guide (415 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 91541

Detailed instructions for use are in the User's Guide.

[. . . ] HI 91541 and HI 9061 have been specifically designed by Hanna Instruments for use in the food industry and are available in two versions: HI 9061C to measure in degrees Celsius; HI 9061F to measure in degrees Fahrenheit. HI 91541C to measure in degrees Celsius; HI 91541F to measure in degrees Fahrenheit. Each HI9061C and HI9061F comes supplied TABLE OF CONTENTS Preliminary Examination . . . . . . . . . . . . . . . . . . . . . . . . . . . Upon request these meters can be supplied with a Factory Calibration Certificate against NIST standard. [. . . ] To switch on, press the ON/OFF key on the front of the unit. ON/OFF HI / LO MEMORIES (for HI 9060 only) The maximum and minimum temperatures are monitored throughout a continuous measuring process. The values may be recalled or cleared at any time during the measurement. Enquiries of the highest or lowest measured temperature may be made by pressing the respective HI or LO keys. The appropriate display indicator will appear together with the value retrieved from memory. Release the key to resume normal operation. °C HI ON/OFF HI If the meter does not come on, make sure that the batteries securely sit in their place. Each time the thermometer is switched on, it will carry a self-test to ensure that no segment is missing. The LCD °C shows a full set of fig°F ures during the self-test. If a temperature probe is plugged in, the unit displays the probe temperature. If a probe is not plugged in, or the cable is defective, the display will show "Er" (for HI 9060 and HI 9061) or "---- (for HI 91541). ----" ---HI LO M °C LO LO By pressing the CLEAR key, the present measurement reading becomes the highest and lowest temperature in memory, i. e. The "HI/LO" display indicator will blink twice to notify user that clearing process is in progress. °C HI LO To switch your thermometer off, press the ON/OFF key again. 8 CLEAR 9 HOLD MODE (for HI 9060 only) The reading hold function is activated by the HOLD key. The measured temperature is frozen on the display when this function key is pressed. A blinking "M" on the display indicates the operating mode. HI 9060 and HI 9061 stop to operate when the low battery signal is detected. The user is warned by the code "Eb". HI 91541 displays "BAT" when the batteries are run down. See also the Battery Replacement section on page 14. BAT °C M HOLD Press the same key again to resume normal operation. HOLD MEASURING SCALE (°C/°F) (for HI9060 only) When the meter is turned on it automatically defaults to the °C scale. °C Measurements can be performed in either the Centigrade or Fahrenheit scale. To change the scale, press the °C/°F key once. LOW BATTERY DETECTION °F °C/°F 10 11 DISPLAY CODES GUIDE Your thermometer is factory programmed to diagnose a fault or warn of low battery levels. Moreover, self-explanatory symbols are used to remind the user of the operating mode or conditions. DISPLAY Er (for HI9060 and HI 9061) ----(for HI 91541) Eb DESCRIPTION The probe is not connected to the instrument or the reading is out of range. Battery weak, need to be replaced. CALIBRATION All Hanna Instruments thermometers have been accurately pre-calibrated at the factory. It is generally recommended to have all thermometers recalibrated at least once a year. For an accurate annual recalibration, contact your nearest Hanna Service Center. Hanna Test Plugs provide a quick and easy way to test the meter's accuracy by simply connecting these Test Plugs to the probe connector of the meter. [. . . ] Reproduction in whole or in part is prohibited without the written consent of the copyright owner. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. 18 Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24VAC or 60VDC. To avoid damages or burns, do not perform any measurement in microwave ovens. In particular cases HI 9060 could switch from °C to °F or vice-versa. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 91541




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 91541 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.