User manual HANNA INSTRUMENTS HI 9110

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9110. We hope that this HANNA INSTRUMENTS HI 9110 user guide will be useful to you.


HANNA INSTRUMENTS HI 9110 : Download the complete user guide (98 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 9110 (984 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9110

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 9110 Portable Waterproof Wine pH Meter Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument. [. . . ] If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. 1. "pH/°C SET" key, to select pH measurement or manual temperature setting mode Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. ISTR9110 06/03 OPERATIONAL GUIDE Initial preparation Install the supplied batteries by following the instructions in the "Battery replacement" section. Connect the HI 1048B pH electrode to the BNC plug on the top of the meter. · Remove the electrode protective cap, submerge the tip (4cm/1. 5") into the sample to be tested and allow the reading to stabilize. · Since pH readings are directly affected by temperature, for accurate measurements, follow the instructions for manual temperature compensation. If the temperature of the sample is significally different from that at which the electrode was stored, allow a few minutes to reach thermal equilibrium. Notes: · Before taking any measurements: - make sure the meter is calibrated. - rinse the electrode thoroughly with some of the sample to be tested, to avoid cross contamination. · After use, switch the instrument off, clean the electrode with HI 70635 and/or HI 70636 solution (see "Accessories" section) and then rinse with clean water. Pour a few drops of HI 70300 storage solution in the protective cap and replace it before storing the electrode. Manual temperature compensation · Press the "pH/°C SET" key to select the manual temperature mode. · Remove the protective cap on the top of the meter to access the trimmers. · Measure the temperature of the solution with the supplied ChecktempC thermometer. · Using the supplied screwdriver, adjust the "T" trimmer to display the measured temperature value, e. g. [. . . ] Reattach the cover and tighten the two screws. · Rinse first with clean water and then with a small amount of pH 3. 00 buffer. Dip the electrode and the ChecktempC into the pH 3. 00 buffer, stir gently and wait for the reading to stabilize. Record the buffer temperature and adjust the "T" trimmer accordingly. · Using the supplied screwdriver, adjust the "pH3" trimmer until the meter displays the pH value at the buffer temperature (see table), e. g. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9110




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9110 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.