User manual HANNA INSTRUMENTS HI 9063

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9063. We hope that this HANNA INSTRUMENTS HI 9063 user guide will be useful to you.


HANNA INSTRUMENTS HI 9063 : Download the complete user guide (416 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 9063 (505 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9063

Detailed instructions for use are in the User's Guide.

[. . . ] These instruments are in compliance with the directives. FUNCTIONAL DESCRIPTION Range (*) Resolution Accuracy (@20°C/68°F) Typical EMC Deviation Display Battery Type Life Probe Environment Dimensions Weight SPECIFICATIONS -50. 0 to 199. 9°C / 200 to 1350°C -58. 0 to 399. 9°F / 400 to 2462°F 0. 1°C (up to 199. 9°C) / 1°C (outside) 0. 1°F (up to 399. 9°F) / 1°F (outside) ±0. 2% F. S. excluding probe error ±3°C (with HI 766 probes) ±6°F (with HI 766 probes) Dual-line LCD 4 x 1. 5V AA (IEC LR6) approx. 2000 hours of continuous use K-type thermocouple (see "Accessories") -10 to 50ºC (14 to 122ºF); RH 100% 196 x 80 x 60 mm (7. 7x3. 1x2. 4") 425 g (15 oz. ) meter only PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. [. . . ] The meter is also provided with low battery detection and BEPS (Battery Error Preventing System), which turns the unit off when the batteries are discharged avoiding erroneous readings caused by low battery level. HI 9063 features include autoranging capability, dual-level LCD for simultaneously displaying of maximum and minimum measured temperatures, °C/°F selection button and hold function. Each meter is supplied complete with 4 x 1. 5V AA batteries and instruction manual. 1. HI/LO values reset key FACTORY RECALIBRATION All Hanna Instruments thermometers have been accurately pre-calibrated at the factory. It is generally recommended to have all thermometers recalibrated at least once a year. For an accurate annual recalibration, contact your nearest Hanna Service Center. 1. Measuring scale, °C or °F OPERATIONAL GUIDE INITIAL PREPARATION Each meter is supplied complete with batteries. Remove the back cover, unwrap the batteries and install them while paying attention to their polarity. If the meter does not come on, make sure that the batteries are correctly installed. The thermometer will carry out a self diagnostic test routine, the LCD will show all segments for a few seconds (or as long as ON/OFF is held), followed by the percentage indication of the remaining battery life. If a temperature probe is plugged in, the meter displays the measured temperature. If no probe is plugged in, or if reading is over-range, the display shows flashing dashes. If a measurement is slightly over the range of the meter specifications, the display flashes the closest full-scale value. To switch the thermometer OFF, press the ON/OFF key. HIGH/LOW TEMPERATURES The maximum and minimum temperatures are continuously monitored and displayed in the lower portion of the LCD. Note: When reading goes over-range, the Hi and Lo values display dashes until cleared. ACCESSORIES K-TYPE THERMOCOUPLE PROBES with integral handle, 1 m (3. 3') cable & mini-connector: HI 766A Roller surface probe, max 320°C/600°F HI 766B Surface probe, max 650°C/1200°F HI 766B1 90º Surface probe, max 450°C/840°F HI 766B2 Spring-loaded, surface probe, max 900°C/1650°F HI 766B3 Spring-loaded, small surface probe with insulated shaft, max 200°C/390°F HI 766C Penetration probe, max 900°C/1650°F HI 766C1 Ultra-fast Penetration probe, max 300°C/ 570°F HI 766D Air probe, max 300°C/570°F HI 766E1 General purpose probe, max 900°C/1650°F HI 766E2 General purpose probe, max 900°C/1650°F HI 766F High temperature, flexible wire probe without handle, max 1100°C/2000°F HI 766F1 Flexible wire probe without handle, max 480°C/ 900°F HI 766TR1 Penetration probe, max 250°C/482°F HI 766TR2 Penetration long probe, max 250°C/482°F HI 766TV1 Pipe clamp probe, max 200°C/390°F with detachable handle & mini-connector (to be used in conjunction with the HI 766HD probe handle): HI 766PA Roller surface probe, max 320°C/600°F HI 766PB Surface probe, max 650°C/1200°F HI 766PC Penetration probe, max 900°C/1650°F HI 766PD Air probe, max 300°C/570°F HI 766PE1 General purpose probe, max 900°C/1650°F HI 766PE2 General purpose probe, max 900°C/1650°F grill surface probe: HI 766B4 Grill surface probe with 70 cm (27. 6'') cable (protected with stainless steel jacket), max 250°C/482°F HI 7664B4S Spare stainless steel sensor for HI766B4 probe CE DECLARATION OF CONFORMITY CLEAR FUNCTION Upon pressing the CLEAR key, the current reading is assigned to the highest and lowest temperature values. The High/Low values may be cleared at any time during measurement. BATTERY REPLACEMENT The instrument is powered by four 1. 5 V alkaline batteries and is provided with the Battery Error Prevention System (BEPS), which turns the unit off when a low battery signal is detected. [. . . ] To avoid electrical shock, do not use these instruments when voltage at the measurement surface exceeds 24VAC or 60VDC. To avoid damage or burns, do not perform any measurement in microwave ovens. HOLD MODE The HOLD function is activated by pressing the HOLD key. The measured temperature is held on the display until HOLD is pressed again. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9063




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9063 will begin.

 