User manual HANNA INSTRUMENTS HI 9032

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9032. We hope that this HANNA INSTRUMENTS HI 9032 user guide will be useful to you.


HANNA INSTRUMENTS HI 9032 : Download the complete user guide (658 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 9032

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 9032 Microprocessor Bench Conductivity/TDS/NaCl Fertilizer/°C/°F Meter with RS 232 These Instruments are in Compliance with the CE Directives http://www. hannainst. com Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. This instrument is in compliance with CSA, UL (EN 50081-1 and EN 50082-1) direcand tives. [. . . ] Pour a small quantity of HI7037 Standard solution into a plastic beaker or any other solution to be used as 100% reference. PROCEDURE WITH ATC · Press the NaCl key to enter the sea water percentage mode, and the "NaCl" symbol will appear on the large display. NaCl NaCl % 9 · Press CAL and the LCD will display "100. 0%". % CAL NaCl CAL · Press the ENTER key and immerse the HI7686 probe into the calibration solution submerging the holes of the sleeve into 31 ENTER 30 the liquid. Immerse the HI 7669/2W temperature probe as close as possible to the conductivity probe. Wait for 2 or 3 minutes for the thermal equilibrium. % Notes: · If the temperature probe is not connected to the meter, once the selected buffer value is confirmed, "25°C" or "77°F" will start blinking on the TEMP. display. · If the buffer is within 39 and 49 mS, the " " symbol stays still. BUF NaCl CAL BUF Enter the sample temperature value using the numerical keys and press the ENTER key to confirm the temperature setting. % ENTER · If the " " starts blinking, wait for approximately 30 seconds for the reading to stabilize. Now the calibration procedure is complete. · To quit from the calibration mode, press the CAL key. CAL NaCl CAL BUF · · Once the reading is stable the " " symbol goes off and CON prompts the user to confirm the reading. % To clear the numeric data entry, press the CLEAR key. PGM Clear NaCl CON BUF PROCEDURE WITHOUT ATC (MTC) · If you need to calibrate without ATC, press the ATC/MTC key and the decimal point will blink on the TEMP. LCD (both in the Celsius and in the Fahrenheit scale). ATC MTC 0 · Press the CON key to confirm the calibration. CON · The instrument is now calibrated and returns to normal operation. During calibration once the selected buffer value is confirmed, "25°C" or "77. 0°F" will start blinking on the TEMP. display to prompt the selection of the calibration temperature value. 32 33 · · · Take the temperature of the solution with a Checktemp or a glass thermometer. Enter the correct buffer temperature value by using the numeric keys ENTER and press ENTER to confirm the temperature setting. Continue the procedure as for calibration with ATC, but without temperature probe connection. FERTILIZER CALIBRATION INITIAL PREPARATION Dissolve 1 g of the fertilizer to be used in 1 L of distilled water. This is to minimize contamination of the calibration solution and secure higher accuracy. When possible, use plastic beakers to minimize any EMC interferences. Fert. PROCEDURE WITH ATC 8 · · · Press the Fert key button to enter the fertilizer #1 mode. Using a small screwdriver adjust the OFFSET trimmer on the rear panel until the reading is "0. 00 gm". gm FERTILIZER · Press the CAL key and "1. 00 gm" will blink on the primary LCD to prompt the user to select the calibration buffer value. The "CAL" symbol will also be displayed. CAL FERTILIZER gm CAL 34 35 · · · · Pour a small quantity of the prepared fertilizer solution into a plastic beaker. Immerse the HI7686 probe into the solution submerging the holes of the sleeve into the liquid. Immerse the HI7669/2W temperature probe as close as possible to the conductivity probe. Press the ENTER key to accept the 1. 00 gm value, otherwise enter manually the desired value through the keyboard followed by the ENTER key to confirm the entry of the calibration value. The " " prompt will appear on the large display and the " " symbol will start blinking. Once the reading is stable, " " and BUF to confirm the calibration and the instrument will return to normal operation. The Fertilizer #1 calibration procedure is now complete. CON HI 9032 can memorize two different measurements of Fertilizer concentration. To perform 2nd Fert calibration press the Fert key and the secondary section on the large LCD will then show "2". Fert. gm 8 FERTILIZER ENTER FERTILIZER gm CAL BUF Proceed with the operation as for the 1st Fert calibration (see above). Notes: · If the HI 7669/2W temperature probe is not connected to the meter, once confirmed the Fert concentration value, "25°C" or "77. 0°F" will start blinking on the TEMP. display. "CAL" will go off and "CON" prompts to confirm the reading. gm FERTILIZER CON BUF Take the temperature of the solution with a Checktemp or a glass thermometer. · Press the CON key 36 37 Enter the correct sample temperature value by using the numerical keys and press ENTER to confirm the temperature setting. · ENTER · Now the calibration procedure is complete. [. . . ] causes the meter to send the Fertilizer 2nd buffer calibration factor value. causes the meter to send the NaCl calibration factor value. 57 Numeric Entries 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, and . The maximum length of a numeric entry is 7 characters (plus DCE and the CR). PROBE MAINTENANCE Rinse the probe with tap water after every series of measurements. If a more thorough cleaning is required, remove the glass sleeve and clean the probe with a cloth or a nonabrasive detergent. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9032




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9032 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.