User manual HANNA INSTRUMENTS HI 3822

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 3822. We hope that this HANNA INSTRUMENTS HI 3822 user guide will be useful to you.


HANNA INSTRUMENTS HI 3822 : Download the complete user guide (302 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 3822

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual Range SPECIFICATIONS 0 to 20 mg/L (ppm) Na 2SO3 0 to 200 mg/L (ppm) Na2SO3 Iodometric method ­ Titration 5 mL & 50 mL 110 (average) 260x120x60 mm (10. 2x4. 7x2. 4") 910 g (34. 0 oz. ) INSTRUCTIONS READ ALL THE INSTRUCTIONS BEFORE USING THE TEST KIT LOOK AT THE BACK PAGE FOR THE ILLUSTRATED PROCEDURE Note: Push and twist pipet tip onto tapered end of syringe ensuring an air tight-fit. HI 3822 Sulfite Test Kit Analysis Method Sample Size Number of Tests Case Dimensions Shipping Weight · Place the syringe tip into the cap port of the plastic vessel and slowly add the titration solution dropwise, swirling to mix after each drop. Continue adding titration solution until the solution in the plastic vessel changes from colorless to blue. [. . . ] It will provide you with the necessary information for correct use of the kit. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately. Each kit is supplied with: · Sulfamic Acid Solution, 1 bottle with dropper (30 mL); · EDTA Reagent, 1 bottle with dropper (30 mL); · Sulphuric Acid solution, 1 bottle with dropper (15 mL); · Starch Indicator, 1 bottle with dropper (10 mL); · HI 3822-0 Reagent Titrant Solution, 1 bottle (120 mL); · 2 calibrated vessels (20 & 50 mL); · 1 calibrated syringe with tip. There are many reasons to monitor sulfite concentration in water. In industrial applications, a sulfite concentration of approximately 20 mg/L must be mantained to prevent pitting and oxidation of metal components as in boiler feed and effluent waters. A high level of sulfite results in a lowered pH, thus promoting corrosion. Sulfite ions are toxic to aquatic lifeforms and their ability to remove dissolved oxygen in water will destroy the delicate balance of ecology of lakes, rivers and ponds. The compact size gives the user the versatility to use the kit practically anywhere. The design of the kit makes it practically impossible to spill the reagents, thereby reducing the possibility of injury or damage to property. Note: mg/L is equivalent to ppm (parts per million). · Add 2 drops of Sulfuric Acid Solution through the cap port and mix as described before. x 20 = Na2SO3 · Add 1 drop of Starch Indicator through the cap port and mix. REFERENCES 1987 Annual Book of ASTM Standard, Volume 11. 01 Water (1), pages 732-736. [. . . ] Insert tip into HI 3822-0 Reagent Titrant Solution and pull the plunger out until the lower edge of the plunger seal is on the 0 mL mark of the syringe. HEALTH AND SAFETY The chemicals contained in this test kit may be hazardous if improperly handled. Read Health and Safety Data Sheets before performing the test. HI 3822 SULFITE TEST KIT 1 2 3 4 5 5 mL sample 6 50 mL sample 7 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 3822




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 3822 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.