User manual HANNA INSTRUMENTS HI 3812

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 3812. We hope that this HANNA INSTRUMENTS HI 3812 user guide will be useful to you.


HANNA INSTRUMENTS HI 3812 : Download the complete user guide (291 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 3812 (272 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 3812

Detailed instructions for use are in the User's Guide.

[. . . ] HI 3812 1 2 HARDNESS TEST KIT 3 4 x5 x1 5 mL sample 50 mL sample 5 Instruction Manual Range SPECIFICATIONS 0 to 30 mg/L (ppm) CaCO3 0 to 300 mg/L (ppm) CaCO3 0. 3 mg/L [in the 0-30 mg/L range] 3 mg/L [in the 0-300 mg/L range] EDTA titration 5 mL and 50 mL (average) 100 (average) 200x120x60 mm (7. 9x4. 7x2. 4") 460 g (1 lb. ) INSTRUCTIONS READ ALL THE INSTRUCTIONS BEFORE USING THE TEST KIT LOOK AT THE BACK PAGE FOR THE ILLUSTRATED PROCEDURE Note: push and twist pipet tip into tapered end of syringe ensuring an air-tight fit. · Continue adding the titration solution until the solution becomes purple, then mix for 15 seconds after each additional drop until the solution turns blue. HI 3812 Hardness Test Kit Smallest Increment Analysis Method Sample Size Number of Tests Case Dimensions Shipping Weight HIGH RANGE ­ 0 to 300 mg/L CaCO3 · Remove the cap from the small plastic vessel. Rinse the plastic vessel with the water sample, fill to the 5 mL mark and replace the cap. [. . . ] The design of the kit makes it easy to handle. LOW RANGE ­ 0 to 30 mg/L CaCO3 x5 If result is lower than 30 mg/L, the precision of the test can be improved by following the procedure below. Rinse it with the water sample, fill to the 50 mL mark and replace the cap. · Read off the milliliters of titration solution from the syringe scale and multiply by 30 to obtain mg/L (ppm) CaCO3. SPECIFICATIONS www. hannainst. com ISTR3812R3 03/02 Dear Customer, Thank you for choosing a Hanna Product. Please read the instructions carefully before using the chemical test kit. It will provide you with the necessary information for correct use of the kit. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately. Each kit is supplied with: · Hardness Buffer, 1 bottle with dropper (30 mL); · Calmagite Indicator, 1 bottle with dropper (10 mL); · HI 3812-0 EDTA Solution, 1 bottle (120 mL); · 1 calibrated plastic vessel (20 mL) with cap; · 1 calibrated plastic vessel (50 mL) with cap; · 1 syringe (1 mL) with tip. Note: any damaged or defective item must be returned in its original packing materials. · Add 1 drop of Calmagite Indicator through the cap port and mix as described above. The solution becomes a redviolet color. x1 x 30 = CaCO 3 REFERENCES Standard Methods for the Examination of Water and Wastewater. [. . . ] Insert tip into HI 3812-0 EDTA Solution and pull the plunger out until the lower edge of the seal is on the 0 mL mark of the syringe. · Place the syringe tip into the cap port of the plastic vessel and slowly add the titration solution dropwise, swirling to mix after each drop. HEALTH AND SAFETY The chemicals contained in this kit may be hazardous if improperly handled. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 3812




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 3812 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.