If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 38040. We hope that this HANNA INSTRUMENTS HI 38040 user guide will be useful to you.


HANNA INSTRUMENTS HI 38040 : Download the complete user guide (60 Ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 38040

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual SPECIFICATIONS Range Smallest Increment Analysis Method Sample Size Number of Tests Case Dimensions Shipping Weight 0 to 5. 0 mg/L (ppm) as Fe 0. 1 mg/L (ppm) Fe Colorimetric 10 mL 100 235x175x115 mm (9. 2x6. 9x4. 5") 427 g (15. 1 oz) INSTRUCTIONS READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT · Using the plastic pipette, fill each glass vial with 10 mL of sample (up to the mark). · Insert one of the vials into the left hand opening of the checker disc. [. . . ] It will provide you with the necessary information for correct use of the kit. If you need additional information, do not hesitate to e-mail us at tech@hannainst. com. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately. Each kit is supplied with: · HI 3834-0 Reagent, packets (100 pcs); · 1 checker disc (containing the 38040 disc); · 2 glass vials with caps; · 1 plastic pipette (3 mL). Note: Any damaged or defective item must be returned in its original packing materials. · Add to the other vial 1 packet of HI 3834-0 reagent. · Remove the cap and insert the reacted sample into the right hand opening of the checker disc. For best results: Perform the reading three times and take the average value (divide by 3 the sum of the three numbers). Intensely colored samples will make the color matching difficult and they should be adequately treated before performing the test. Suspended matter in large amounts should be removed by prior filtration. When not in use, keep the disc protected from light, in a cool and dry place. [. . . ] · Keep the checker disc at a distance of 30-40 cm (1216") from the eyes to match the color, while having a HEALTH AND SAFETY The chemicals contained in this kit may be hazardous if improperly handled. Read the relevant Health and Safety Data Sheet before performing this test. ISTR38040 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 38040




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 38040 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.