User manual HANNA INSTRUMENTS HI 145-00

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 145-00. We hope that this HANNA INSTRUMENTS HI 145-00 user guide will be useful to you.


HANNA INSTRUMENTS HI 145-00 : Download the complete user guide (59 Ko)

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 145-00 (40 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 145-00

Detailed instructions for use are in the User's Guide.

[. . . ] SPECIFICATIONS: HI 145-00 HI 145-20 Instruction Manual HI 145-01 HI 145-30 °C Range -50. 0 to 220°C °F -58. 0 to 428°F Resolution 0. 1°C(-50 to199°C) 0. 1°F(-20. 0 to 199°F) 1°C(200 to 220°C) 1°F (200 to 428°F) Accuracy ±0. 3°C (-20 to 90°C) ±0. 5°F (-4 to 194°F) ±0. 4% F. S. (outside) ±0. 4% F. S. (outside) ±0. 3°C ±0. 5°F HI 145-00 HI 145-01 HI 145-20 HI 145-30 Rugged Waterproof Thermometers Typical EMC Deviation Battery Type Battery Life Alkaline 1 x 1. 5V AAA type approx. [. . . ] The stainless steel probe is 125 mm (5") long and has a 5 mm (0. 2") diameter. HI 145-20 (Celsius) and HI 145-30 (Fahrenheit) have been especially designed for temperature measurement of hot liquids. The stainless steel probe is 300 mm (12") long and has a 5mm (0. 2") diameter. semi-solid samples. A blinking M appears on the right side of the LCD to indicate that reading has been memorized. Press either the HOLD 20. 0 M or ON/OFF button to return to normal measurement mode. ON OFF HOLD HI 145 · When not in use, switch the HI 145 off, or else the meter will automatically switch off itself after 8 minutes. · Variations in readings or fading display can indicate a weak battery (see below). OPERATION: · Turn the HI 145 on. "CAL" will appear on the LCD, to indicate an automatic calibration check. Subequent to a successful cali20. 0 bration check, the LCD will display "-0-". If the calibration check is unsuccessful, the LCD will display "ERR", which means the meter requires factory calibration. [. . . ] PROTECTIVE CAP: With the thermometer, is supplied with a protective cap, which can also be used to hold the thermometer on the side of a vessel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 145-00




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 145-00 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.