User manual HANNA INSTRUMENTS DIST 8

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS DIST 8. We hope that this HANNA INSTRUMENTS DIST 8 user guide will be useful to you.


HANNA INSTRUMENTS DIST 8 : Download the complete user guide (440 Ko)

Manual abstract: user guide HANNA INSTRUMENTS DIST 8

Detailed instructions for use are in the User's Guide.

[. . . ] (EC/TDS) Typical EMC Deviation ±0. 5°C / ±1°F ±2% f. s. (EC/TDS) Temperature Automatic, Compensation with adjustable from 0. 0 to 2. 4%/ºC TDS Factor Adjustable from 0. 45 to 1. 00 (CONV) Calibration Automatic, 1 point Calibration Solutions DiST 7 HI 7031 (1413 µS/cm) HI 7032 (1382 ppm with CONV=0. 5) HI 70442 (1500 ppm with CONV=0. 7) DiST 8 HI 7030 (12. 88 mS/cm) HI 70038 (6. 44 ppt with CONV=0. 5 or 9. 02 ppt with CONV=0. 7) Environment 0 to 50°C (32 to 122°F); RH 100% Battery Type 4 x 1. 5V AA Battery Life Approx. 2000 hours of use Auto-off After 8 minutes of non-use Dimensions 120 x 53 x 81 mm (4. 7 x 2. 1 x 3. 2") Weight 205 g (7. 2 oz) PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. [. . . ] In addition, the Battery Error Prevention System (BEPS) automatically turns the meter off for avoiding erroneous readings caused by low voltage level. The built-in temperature and conductivity sensors are protected inside the cell cup. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. OPERATIONAL GUIDE To turn the meter on and check the battery status Press and hold the MODE button for 2-3 seconds. All the used segments of the LCD will be visible for a few seconds, followed by a percent indication of the remaining battery life (eg. Taking measurements Rinse and fill the cell cup with the solution to be tested. The measurements should be taken when the stability indicator on the top left of the LCD disappears. The EC (or TDS) value automatically compensated for temperature variations, is shown on the LCD together with the temperature of the sample. To change the temperature unit To change the temperature unit (from °C to °F), from measurement mode press and hold the MODE button until TEMP and the current temperature unit are displayed on the lower LCD (eg. Use the SET/HOLD button to change the temperature unit, and then press the MODE button twice to return to normal measurement mode. To freeze the display Press and hold the SET/HOLD button until "HOLD" appears on the secondary display. To turn the meter off Press the MODE button while in normal measurement mode. Notes · Before taking any measurement make sure the meter has been calibrated. · If measurements are taken in different samples successively, rinse the cell cup thoroughly with water, and then with some of the sample to be measured. CALIBRATION For better accuracy, frequent calibration of the instrument is recommended. In addition, the instrument must be recalibrated whenever: a) After testing aggressive chemicals. To change the TDS factor (CONV) and the temperature compensation coefficient (BETA) · From measurement mode, press & hold the MODE button until TEMP and the current temperature unit are displayed on the lower LCD (eg. · Press the MODE button again to show the current conversion factor (eg. · Press the MODE button to show the current temperature compensation coefficient (eg. Calibration procedure · From measurement mode, press & hold the MODE button until CAL is displayed on the lower LCD. [. . . ] Remove the screw and the washer in the battery compartment and carefully replace the 4 batteries located in the compartment, while paying attention to their polarity. CE DECLARATION OF CONFORMITY Replace the washer and tighten the screw in the compartment; replace the bottom, ensuring that the gasket is in place before tightening the screws. Batteries should only be replaced in a non-hazardous area using the battery type specified in this instruction manual. ACCESSORIES HI 70030P HI 70031P HI 70032P HI 70038P HI 70442P HI 7030M HI 7031M HI 7032M HI 7038M HI 70442M 12. 88 mS/cm solution, 20 mL sachet, 25 pcs 1413 µS/cm solution, 20 mL sachet, 25 pcs 1382 ppm solution, 20 mL sachet, 25 pcs 6. 44 ppt solution, 20 mL sachet, 25 pcs 1500 ppm solution, 20 mL sachet, 25 pcs 12. 88 mS/cm solution, 230 mL bottle 1413 µS/cm solution, 230 mL bottle 1382 ppm solution, 230 mL bottle 6. 44 ppt solution, 230 mL bottle 1500 ppm solution, 230 mL bottle Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. Operation of this instrument in residential areas could cause unacceptable interferences to radio and TV equipment. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS DIST 8




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS DIST 8 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.