User manual HANNA INSTRUMENTS C 226

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS C 226. We hope that this HANNA INSTRUMENTS C 226 user guide will be useful to you.


HANNA INSTRUMENTS C 226 : Download the complete user guide (1227 Ko)

Manual abstract: user guide HANNA INSTRUMENTS C 226

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual C 216 & C 226 Multiparameter Bench Photometers for Pool & Spa Applications www. hannainst. com These Instruments are in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. These instruments are in compliance with directives. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . [. . . ] · Fill the cuvet with 10 mL of unreacted sample, up to the mark, and replace the cap. · Place the cuvet into the holder and ensure that the notch on the cap is positioned securely into the groove. · Press ZERO and "SIP" will blink on the display. 10 mL Alkalinity 22 · Wait for a few seconds and the display will show "-0. 0-". · Add carefully the content of one packet of HI 93755-0 Alkalinity Indicator Reagent. Note: Pay attention not to spill reagent otherwise full color development may be inhibithed. · Replace the cuvet into the holder and ensure that the notch on the cap is positioned securely into the groove. · Press TIMER and the display will show the countdown prior to measurement. In both cases "SIP" will blink during measurement. · The instrument directly displays the alkalinity in mg/L of CaCO3 on the Liquid Crystal Display. 23 Alkalinity BROMINE SPECIFICATIONS Range Resolution Precision Typical EMC Deviation Light Source Method 0. 00 to 10. 00 mg/L 0. 01 mg/L ±0. 05 mg/L @ 2. 00 mg/L ±0. 01 mg/L Tungsten lamp with narrow band interference filter @ 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample. Description DPD Powder Reagent Quantity/test 1 packet REQUIRED REAGENTS Code HI 93716-0 REAGENT SETS HI 93716-01 Reagents for 100 tests HI 93716-03 Reagents for 300 tests For other accessories see page 49. MEASUREMENT PROCEDURE · Select the program number corresponding to Bromine on the secondary LCD by pressing PROGRAM and . · Fill the cuvet with 10 mL of unreacted sample, up to the mark, and replace the cap. · Place the cuvet into the holder and ensure that the notch on the cap is positioned securely into the groove. · Press ZERO and "SIP" will blink on the display. 10 mL Bromine 24 · Wait for a few seconds and the display will show "-0. 0-". Replace the cap and shake gently for about 20 seconds to dissolve most of the reagent. · Replace the cuvet into the holder and ensure that the notch on the cap is positioned securely into the groove. · Press TIMER and the display will show the countdown prior to measurement. Alternatively, wait for 2 minutes and 30 seconds and press READ DIRECT. In both cases "SIP" will blink during measurement. · The instrument directly displays concentration in mg/L of bromine on the Liquid Crystal Display. INTERFERENCES Interference may be caused by: Chlorine, Chlorine Dioxide, Ozone. In case of water with hardness greater than 500 mg/L CaCO3, shake the sample for approximately 2 minutes after adding the reagent. In case of water with alkalinity greater than 250 mg/L CaCO3, the color of the sample may develop only partially, or may rapidly fade. To resolve this, neutralize the sample with diluted HCl. 25 Bromine CALCIUM HARDNESS SPECIFICATIONS Range Resolution Precision Typical EMC Deviation Light Source Method 0 to 500 mg/L (as CaCO3) 5 mg/L ±10 mg/L @ 200 mg/L ±5 mg/L Tungsten lamp with narrow band interference filter @ 525 nm Colorimetric Method. The reaction between calcium and the reagents causes a violet to orange tint in the sample. [. . . ] Use HI 920010 cable to connect the meter to the PC, start the terminal program and set the communication options as follows: 8, N, 1, no flow control. Command Types To send a command to the meter the scheme is: <DLE> <command> <CR> This line makes the computer send a Data Link Escape character (/ or ?), the command expressed as a number or a 3-character sequence and a CR character. Note: Windows Terminal® and all the other terminal programs that support the ANSI escape sequence, represent the DLE character by the string `^P' and the CR character by the string `^M'. Type of Commands /OFF - Turn the meter OFF /PDR - Press Read Direct /PTR - Press Timer /PZR - Press Zero Excel© Copyright of "Microsoft Co. " Lotus 1-2-3© Copyright of "Lotus Co. " TELIX is registered Trademark of "Deltacomm" Windows® and Windows Terminal® are registered Trademark of "Microsoft Co. " ® 46 /PUP - Program Up /PDN - Program Down /PTM - Turn Test Mode On /Brx - Set the baud rate 1 - 300 2 - 600 3 - 1200 4 - 2400 /KBL - Lock Keyboard /KBU - Unlock Keyboard ?PR# - Send Current Program Number ?BRQ - Send current baud rate 1 - 150 2 - 300 3 - 600 4 - 1200 5 - 2400 ?CNQ - Send Concentration (three bytes) conc decimal point unit m - ppm b - ppb t - ppt u - pcu h - pH ?ERR - send error / status information 0 - No error 1 - CAP 2 - HI 3 - ZERO 4 - LO 5 - IDLE 6 - ZERO DONE 7 - TIMED READ 47 STANDARD METHODS Description Alcalinity Bromine Calcium Hardness Chlorine, Free Chlorine, Total Copper, Free Copper, Total Cyanuric Acid Iron Ozone pH Range 0 to 500 mg / L 0. 00 to 10. 00 mg / L 0 to 500 mg / L 0. 00 to 5. 00 mg / L 0. 00 to 5. 00 mg / L 0. 00 to 5. 00 mg / L 0. 00 to 5. 00 mg / L 0 to 200 mg / L 0. 00 to 5. 00 mg / L 0. 00 to 2. 00 mg / L 6. 5 to 8. 5 pH Method Colorimetric DPD Colorimetric DPD DPD Bicinchoninate Bicinchoninate Turbidimetric Phenantroline DPD Phenol Red BATTERY REPLACEMENT To prolong battery life, switch your meter off after use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS C 226




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS C 226 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.