User manual HANNA INSTRUMENTS BL 983322

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HANNA INSTRUMENTS BL 983322. We hope that this HANNA INSTRUMENTS BL 983322 user guide will be useful to you.


HANNA INSTRUMENTS BL 983322 : Download the complete user guide (553 Ko)

Manual abstract: user guide HANNA INSTRUMENTS BL 983322

Detailed instructions for use are in the User's Guide.

[. . . ] These instruments are in compliance with the directives. SPECIFICATIONS Range 0. 00 to 19. 99 µS/cm Resolution 0. 01 µS/cm Accuracy (@ 20°C/68°F) ±2% f. s. Probe HI 7634-00 EC/TDS probe (not included) Temp. Compensation Automatic from 5 to 50°C (41 to 122°F); ß=2%/ºC Calibration Manual, through CAL trimmer Dosing Contact Maximum 2A (fuse protected), 250 Vac, 30 Vdc Contact close when measure > setpoint Setpoint Adjustable, from 0 to 19. 99 µS/cm Overtime Adjustable, typically from 5 to approx. 30 minutes Power Consumption 10 VA Installation Category II Power supply: External (fuse protected) BL983322-0 12 Vdc BL983322-1 115/230 Vac ; 50/60Hz Dimensions 83 x 53 x 99 mm (3. 3x2. 1x3. 9") CE DECLARATION OF CONFORMITY PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. [. . . ] Two models are available: · BL 983322-0 powered at 12 Vdc · BL 983322-1 powered at 115 or 230 Vac ASSEMBLING VIEW HI 7634-00 HI 7061M HI 7061L HI 710005 HI 710006 HI 710012 HI 710013 HI 710014 HI 731326 HI 740146 ACCESSORIES EC/TDS probe Probe cleaning solution, 230 mL bottle Probe cleaning solution, 500 mL bottle 12 Vdc power adapter, US plug 12 Vdc power adapter, European plug 12 Vdc power adapter, Australian plug 12 Vdc power adapter, South African plug 12 Vdc power adapter, UK plug Calibration screwdriver (20 pcs) Mounting brackets Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24 Vac or 60 Vdc. To avoid damages or burns, do not perform any measurement in microwave ovens. FUNCTIONAL DESCRIPTION Front panel Rear panel OPERATIONS REAR PANEL CONNECTIONS Terminals #1: Probe · Connect the HI 7634-00 probe by following the wires colour indications. Terminals #2: Power Supply · Model BL983322-0: connect the 2 wires of a 12 Vdc power adapter to the terminals +12 Vdc and GND. · Model BL983322-1: connect a 3-wire power cable to the terminals while paying attention to the correct earth (PE), line (L) and neutral (N1 for 115 V or N2 for 230 V) contacts. Terminals #3: Dosing Contact · This contact drives the dosing system, accordingly to the selected setpoint. Note: The setpoint has a typical hysteresis value comparable to the meter accuracy. Terminals #4: Not Used Contact Overtime system: jumper (#5) and trimmer (#6) · This system allows the user to set a maximum dosing period, by adjusting the rear trimmer from 5 (min) to approx. · When the set time is exceeded, any dosing action stops, the LED indicator on the front panel will blink Red and the LCD will show the "TIMEOUT" warning message. To exit the overtime condition, set the OFF/Auto/ON switch to "OFF" position, and then to "Auto" again. · For disabling the overtime feature, simply remove the jumper on the rear panel. Note: The overtime system works only if the OFF/Auto/ON switch is in "Auto" position. OPERATING THE METER Before proceeding make sure that: · the meter has been calibrated; · the setpoint value has been properly adjusted; · all rear panel wiring and selections are correct; · the Auto/OFF/ON switch is in the desired position. Install or immerse the probe in the solution to be monitored, then press the "MEAS" key (if necessary). [. . . ] 3-colour LED indicator: · Green = meter in measurement mode · Orange/Yellow = dosing in progress · Red, blinking = indicates an alarm condition 1. Power supply terminal: · for BL983322-0 model: 12 Vdc adapter · for BL983322-1 model: 115 Vac or 230 Vac option 3. Jumper for enabling (jumper in) or disabling (jumper removed) the overtime control 6. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS BL 983322




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS BL 983322 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.