Detailed instructions for use are in the User's Guide.
[. . . ] If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
OUTLET INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Clock set
Press CLOCK button, "AM" or "PM" flashes. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
POWER/SOFT
2
Operation
Base Operation
Remote controller
Emergency operation and test operation
Emergency Operation:
Pi
POWER/SOFT
Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, the" Pi "sound is heard once, which means the start of this operation. [. . . ] In COOL mode, fan speed automatically takes
high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode.
(2) SOFT Operation
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed
automatically takes low speed of AUTO fan mode.
Note
1 hr Rises 1OC 1 hr Rises 1OC
Temp. setting
During POWER operation, in rapid HEAT or COOL mode the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
Unit stop
In COOL, DRY mode
To cancel POWER or SOFT operation
Press POWER/SOFT button again , POWER or SOFT disappears.
2. In HEAT mode 1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. setting so that room temperature won't be too high for your sleep.
Temp. setting
1 hr Decreases 2OC 1 hr Decreases 2 C
O
HEALTH Operation
Unit stop
Healthy Negative ions
3 hrs
3 hrs
Rises 1OC
SLEEP operation starts
SLEEP operation stops
In HEAT mode
The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
4
Operation
Timer On/Off On-Off Operation
Set clock correctly before starting TIMER operation. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS
CE
All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC
ROHS
The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3. Press HOUR
button to set time.
It can be adjusted within 24 hours. 4. After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing. 5. Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
WEEE
In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation.
IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
A B C
R410A
2 1
1= 2= 1+2=
kg kg kg
D
F
E
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink, ·1 the factory refrigerant charge of the product ·2 the additional refrigerant amount charged in the field and · 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e. g. The green side of the bacteria-killing medium air purifying filter face outside, and the white side face the unit.
5. Close the Inlet Grille
Close the Grille surely
Detach old Air Purifying Filter
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months.
3. Attach Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames.
The bacteria-killing medium air purifying filter will be used for a long time, no need for replacement. But in the period of using them , you should remove the dust frequently by using vacuum cleaner or flaping them lightly, otherwise , its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it, or its ability of sterilization will be reduced.
6
Cautions
WARNING
Please call Sales/Service Shop for the Installation. [. . . ] If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse of indoor unit on PC board is broken, please change it with the type of T. If the fuse of outdoor unit is broken, change it with the type of T. 25A/250V 4. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of appliance by a person responsible for their safety. [. . . ]