User manual HAIER HSU-22C13

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-22C13. We hope that this HAIER HSU-22C13 user guide will be useful to you.


HAIER HSU-22C13 : Download the complete user guide (664 Ko)

Manual abstract: user guide HAIER HSU-22C13

Detailed instructions for use are in the User's Guide.

[. . . ] Air Conditioner Edition:2006/01/09 CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE . SERVICE MANUAL Air Conditioners MODEL: HSU-09C13 MODEL: HSU-12C13 MODEL: HSU-18C13 MODEL: HSU-22C13 THIS MANUAL IS USED BY QUALIFIED APPLIANCE TECHNICIANS ONLY. HAIER DOES NOT ASSUME ANY RESPONSIBILITY FOR PROPERTY DAMAGE OR PERSONAL INJURY FOR IMPROPER SERVICE PROCEDURES DONE BY ONE UNQUALIFIED PERSON. REVISION 0 Air Conditioner Edition:2006/01/09 IMPORTANT INFORMATION HSU-09/12C13 HSU-22C13 Features Comfortable: wide-angle airflow Wide variety of functions HSU-18C13 quiet operation Main Specification Model:HSU-09C13 Cooling Capacity 2600W 960W/4. 5A Model:HSU-12C13 Cooling Capacity:3500W Rated Power/Current(cooling):1250W/5. 8A EER:2. 80 Air Volume(Indoor/outdoor):540m3/h Power: 1PH 220V~ 60 Hz Model:HSU-22C13 Cooling Capacity:6000W Rated Power/Current(cooling):2200W/10. 4A EER:2. 73 Air Volume(Indoor/outdoor):700m3/h Power: 1PH 220V~ 60 Hz Rated Power/Current(cooling) EER: 2. 71 Air Volume(Indoor/outdoor):420m3/h Power: 1PH 220V~ 60 Hz Model:HSU-18C13 Cooling Capacity:5000W Rated Power/Current(cooling):1700W/7. 9A EER:2. 94 Air Volume(Indoor/outdoor):700m3/h Power: 1PH 220V~ 60 Hz Air Conditioner Edition:2006/01/09 Safety Information General Information This Service Manual describes the operation, disassembly, troubleshooting, and repair of Haier Room Air Conditioners, etc. It is intended for use by authorized servicers who troubleshoot and repair these units. NOTE:It is assumed that users of this manual are familiar with the use of tools and equipment used to troubleshoot and repair electrical, mechanical, and refrigeration systems;and understand the terminology used to describe and discuss them. [. . . ] Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if timer setting is the same as previous one. 16 Air Conditioner Edition:2006/01/09 Operation TIMER ON-OFF TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. (2) Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: ON TIMER ON OFF TIMER OFF ON OFF blank TIMER ON-OFF Select TIMER ON-OFF. "ON" will flash. (3)Time setting for TIMER ON Press HOUR button. Every time the button is pressed, time increases 10 min. AM refers to morning and PM to afternoon ON/OFF TEMP MODE 1 3 SET 6 TIMER FAN 5 SWING 2 4 CLOCK SLEEP (4) Time confirming for TIMER ON After time setting, press TIMER button to confirm. Time displayed: Unit starts at x hour x min. LOCK RESET (5)Time setting for TIMER OFF Follow the same procedures in "Time setting for TIMER ON". (6) Time confirming for TIMER OFF After time setting, press SET button to confirm, "OFF" stops flashing Time displayed: Unit stops at X hour X min. To cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. 17 Air Conditioner Edition:2006/01/09 Operation Emergency operation and test operation Emergency Operation: Carry out this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, a" Pi "sound starts once, which means the start of this operation. In this operation, it is not possible to change the Pi settings of temperature and air flow speed, it is also impossible to do an operation by the timer. Room Designated temperature temperature More than 23 C Less than 23 C o o Timer mode Air flow Operation speed mode COOL HEAT 26 C 23 C o o CONTINUOUS AUTO CONTINUOUS AUTO If an air conditioner is a model for both cooling and heating. Cooling when the room temperature at the start of operation is above 23 C. o Heating when the room temperature at the start of operation is below 23 C o Test operation: Use this switch in the test operation when the room o temperature is less 16 C, do not use it in the normal operation. After you hear the "Pi" sound twice, release your finger from the switch, the cooling operation starts with the air flow speed setting "Hi". Pi. . . Pi Pi Removal of the restriction of emergency or test operation: Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the restriction of emergency or test operation to be removed. When the remote controller is manipulated for the removal, then the selected operation by the remote controller. 18 Air Conditioner Edition:2006/01/09 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. In COOL mode One hour after SLEEP mode starts, temp. won't be too low for your sleep. (As shown in Fig. l) o o ON/OFF TEMP MODE SET FAN TIMER SWING CLOCK SLEEP LOCK RESET In HEAT mode One hour after SLEEP mode starts, temp. (As shown in Fig . 2) SLEEP operation starts SLEEP operation stops Approx. setting Unit stop Power Failure Resume Function If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, the power indicator lights up, and 3 minutes later the compressor starts running with the indicator lighting up. Fig. 1 Temp. setting decreases 2oC decreases 2oC Unit stop 1 hr 1 hr Approx. 3 hrs 3 hrs Rises 1oC Note: In AUTO mode, unit will run in SLEEP function according to operation mode. In FAN mode, comfortable sleep is not available. SLEEP mode starts SLEEP mode stops Fig. 2 19 Air Conditioner Edition:2006/01/09 Maintenance Different models have different appearance Cleaning of unit casing Cut off power supply before cleaning unit casing with soft cloth. squeeze water in the cloth, wipe off the detergent on unit casing completely. Cleaning of remote controller Cleaning of air filter Don't use water to wash unit casing, please use dry cloth. Don't use glass cleaner or cloth soaked with chemicals. Air Filter 1. Open inlet grille by pulling it upward. 3. Clean the filter Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. 2. Remove air filter Push up the filter's center tab slightly until it is caesura of the stopper. Remove it by pulling down. 5. Close the inlet grille. 4. Attach the filter Attach filter behind the stopper so that the "Front" indication is facing to the front. [. . . ] Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. Insert the cable according to terminal number in the same manner as the indoor unit. If wiring is not correct, proper operation can not be carried out and controller may be damaged. Fix the cable with a clamp. 4. Attaching Drain-Elbow If the drain-elbow is used, please attach it as figure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-22C13




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-22C13 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.