User manual HAIER HSU-12LEA13-M
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-12LEA13-M. We hope that this HAIER HSU-12LEA13-M user guide will be useful to you.
You may also download the following manuals related to this product:
HAIER HSU-12LEA13-M annexe 3 (1893 ko)
HAIER HSU-12LEA13-M annexe 2 (547 ko)
HAIER HSU-12LEA13-M annexe 1 (594 ko)
Manual abstract: user guide HAIER HSU-12LEA13-M
Detailed instructions for use are in the User's Guide.
[. . . ] SIGNAL SENDING 7. TIMER OFF display
AUTO
LO
MED
HI
7 TIMER OFF display
TIMER ON display SLEEP display
Dry display
NOTE: Cooling only unit do not have displays and functions related with heating If the unit which you purchased has healthy function, follow it. If not, please ignore.
Loading of the battery
2 1 3
Outdoor Unit
1 Remove the battery cover; 2 Load the batteries as
illustrated. 2 R-03 batteries, resetting key(cylinder);
OUTLET INLET
CONNECTING PIPING AND ELECTRICAL WIRING
4
is in line with the " + "/"-"; Load the battery, then put on the cover again.
3 Be sure that the loading
4 1 DRAIN HOSE
Clock set
Press CLOCK button, "AM" or "PM" flashes. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
TIMER CLOCK SET
LOCK
Note: The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. [. . . ] In SOFT operation mode, fan speed
TIMER CLOCK SET SLEEP
automatically takes low speed of AUTO fan mode.
Healthy Negative ions
To cancel SOFT operation
Press POWER/SOFT button again , POWER/SOFT disappears.
TIMER Operation
Set Clock correctly before starting Timer operation You can let unit start or stop automatically a following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. (1) TIMER ON
Emergency operation and test operation
Emergency Operation:
Pi
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed, the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or fan or heat, according to the room temperature.
TIMER CLOCK SET SLEEP
TIMER CLOCK SET SLEEP
Room temperature
Operation mode
Designated temperature 26OC 23OC Operation mode FAN
Timer mode NO NO
Air flow
AUTOMATIC AUTOMATIC
ABOVE 23OC COOLING
TIMER CLOCK SET SLEEP
(2) TIMER OFF
BELOW 23OC
HEAT
(Cooling only uint Room temperature BELOW 23OC
Designated temperature 26OC
Timer mode NO
Air flow
AUTOMATIC
It is not possible to operate in dry mode.
TIMER CLOCK SET SLEEP TIMER CLOCK SET SLEEP
Test operation:
(3) TIMER ON-OFF
TIMER CLOCK SET SLEEP
TIMER CLOCK SET SLEEP
TIMER CLOCK SET SLEEP
TIMER CLOCK SET SLEEP
To cancel TIMER mode
Just press TIMER button several times untilTIMER mode disappears.
Test operation switch is the same as emergency switch. Use this switch in the test operation when the room o temperature is below 16 C, do not use it in the normal operation. Pi Pi Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
3
Operation
Comfortable SLEEP
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
SLEEP Operation
TIMER CLOCK SET SLEEP
1 hours after SLEEP mode starts, temp will become 2OC lower than temp. setting. setting so that room temperature won't be too high for your sleep.
2. In HEAT mode
Temp. setting 1 hr 1 hr
O
Unit stop
Decreases 2 C
O
Decreases 2 C 3 hrs Rises 1 C 3 hrs SLEEP SLEEP operation stops operation starts In HEAT mode
O
Operation Mode
1. setting so that room temperature won't be too Iow for your sleep. SLEEP operation stops SLEEP operation starts Approx. 6hrs
3. In AUTO mode The unit operates in corresponding sleep mode corresponding sleep mode adapted to the automatically selected operation mode. When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted. When TIMER function is set, the quiet sleeping function can't be set up. After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on, if the two modes are set up at the same time, either of their operation time is ended first , the unit will stop automatically, and the other mode will be cancelled.
1 hr 1 hr
Rises 1 C
O O
Rises1 C
Unit stop Temp. setting In COOL, DRY mode
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. STRICT ENFORCEMENT
Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
Use an exclusive power source with a circuit breaker
WARNING
WARNING
Check proper installation of the drainage securely
STRICT ENFORCEMENT
OFF Connect power supply cord to the outlet completely
Use the proper voltage
STRICT STRICT ENFORCEMENT ENFORCEMENT Do not use power supply Take care not to damage the power supply cord. cord in a bundle.
1. Do not use power supply cord extended or connected in halfway 2. Do not install in the place where there is any possibility of inflammable gas leakage around the unit. PROHIBITION Do not insert objects into the air inlet or outlet.
PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION Do not channel the air flow directly at people, especially at infants or the aged. Do not try to repair or reconstruct by yourself.
PROHIBITION
Connect the earth cable.
PROHIBITION
PROHIBITION
earthing
Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with food, art work, precise equipment, when gas appliance is running at the wet hand. STRICT ENFORCEMENT Check good condition of the installation stand
CAUTION
PROHIBITION Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION Do not pour water onto the unit for cleaning
PROHIBITION Do not place animals or plants in the direct path of the air flow
PROHIBITION Do not place any objects on or climb on the unit.
PROHIBITION Do not place flower vase or water containers on the top of the unit.
PROHIBITION
PROHIBITION
PROHIBITION
6
Trouble shooting
Before asking for service, check the following first.
Phenomenon The system does not restart immediately. Cause or check points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. [. . . ] If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 4. The distance between the indoor unit and the floor should be more than 2m. 8. The appliance is not intended to use by young children or infirm persons without supervision. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12LEA13-M
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12LEA13-M will begin.