User manual HAIER HSU-12HVA104-R2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-12HVA104-R2. We hope that this HAIER HSU-12HVA104-R2 user guide will be useful to you.


HAIER HSU-12HVA104-R2 : Download the complete user guide (538 Ko)

Manual abstract: user guide HAIER HSU-12HVA104-R2

Detailed instructions for use are in the User's Guide.

[. . . ] Place, where a distance marked is available as illustrated in the above figure. Power Source Before inserting power plug into receptacle, check the voltage without fail. A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it. Selection of pipe To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation. [. . . ] Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop. 4 Indoor unit When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. -mod 07-09-12: 4G1. 5mm2 -mod 18: 3G2. 5mm2+1x0. 75mm2 -mod 22: 4G0. 75mm2 2. If the fuse on PC board is broken please change it with the type of T. After installation, the power plug should be easily reached. L Indoor unit Outdoor unit Indoor unit { POWER PLUG N HSU-07HV03/R2(DB) HSU-09HV03/R2(DB) HSU-12HV03/R2(DB) HSU-18HV03/R2(DB) HSU-12HVB03/R2(DB) HSU-09HVA104/R2(DB) HSU-12HVA104/R2(DB) HSU-22HV03/R2(DB) Outdoor unit Power cable: -mod 07-09-12: 3G1. 5mm2 -mod 18-22: 3G2. 5mm2 claw of the clip 5. Easily-demount cleaning of indoor unit 1. Top inlet can be taken down Open the inlet grille, press the claw of the clip on the unit, then take down the top inlet. (according to figure 1) 2. Vertical flap can be taken down Overturn the vertical flap, press the claw of the clip , then take down vertical flap. (according to figure 2) 3. Horizontal louvers can be taken down After taking down vertical flap. Horizontal louvers are appeared, draw the middle louver, and take down the horizontal louvers . (according to figure 3) Figure 2 Figure 1 Figure 2 Daff Figure 3 5 Outdoor unit 1. Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2. Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. The max vertical distance between the indoor unit and the outdoor unit is 5 m. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening torque 18N. m 40N. m 55N. m Liquid side 6. 35mm(1/4") Gas side 9. 52mm(3/8") Spanner Gas side 12. 7mm(1/2") Torque wrench Be careful that matters, such as wastes of sands, etc. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional refrigerant. 3. Connection Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. [. . . ] After 6 seconds, close the 2-way valve and make the inspection of gas leakage. Open Close 2-way valve 3-way valve 90 O 5 No gas leakage? In case of gas leakage, tighten parts of pipe connection. 6 If it does not stop gas leakage, discharge whole refrigerants from the service port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12HVA104-R2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12HVA104-R2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.