User manual HAIER HSU-12HV03

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-12HV03. We hope that this HAIER HSU-12HV03 user guide will be useful to you.


HAIER HSU-12HV03 : Download the complete user guide (1141 Ko)

You may also download the following manuals related to this product:

   HAIER HSU-12HV03 (12298 ko)
   HAIER HSU-12HV03 annexe 1 (12298 ko)

Manual abstract: user guide HAIER HSU-12HV03

Detailed instructions for use are in the User's Guide.

[. . . ] The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon. For the purpose of the safety, the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before openning inlet grill. Inadequate repairs may result in a major source of danger for the user of the air conditioner. Do not damage any parts of the air All these valuable materials may be taken to conditioner that carry refrigerant by piercing a waste collecting center and used again after or performating the air conditioner's tubes adequate recycling. [. . . ] Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. Connect the earth cable. Do not install in the Do not get the unit place where there is exposed to vapor any possibility of or oil steam. inflammable gas leakage around the unit. Check proper installation of the drainage securely earthing PROHIBITION PROHIBITION STRICT ENFORCEMENT 3 Cautions WARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Use an exclusive power source with a circuit breaker STRICT ENFORCEMENT Use the proper voltage Do not use power supply cord extended or connected in halfway OFF Connect power supply cord to the outlet completely STRICT ENFORCEMENT Do not use power supply cord in a bundle. STRICT ENFORCEMENT Take care not to damage the power supply cord. PROHIBITION Do not insert objects into the air inlet or outlet. PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on. PROHIBITION Do not channel the air flow directly at people, especially at infants or the aged. PROHIBITION Do not try to repair or reconstruct by yourself. PROHIBITION PROHIBITION CAUTION Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with food, art work, precise equipment, when gas appliance is running at the wet hand. same time. PROHIBITION Do not install the unit near a fireplace or other heating apparatus. STRICT ENFORCEMENT Check good condition of the installation stand PROHIBITION Do not pour water onto the unit for cleaning PROHIBITION Do not place animals or plants in the direct path of the air flow PROHIBITION Do not place any objects on or climb on the unit. PROHIBITION Do not place flower vase or water containers on the top of the unit. PROHIBITION PROHIBITION PROHIBITION 4 Parts and Functions Indoor unit Display board Inlet Air Purifying Filter (inside) Inlet grille Vertical flap (adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) Anion generator (inside) Power plug Outlet Air filter(inside) Outdoor unit HSU-09LV03 HSU-09HV03 HSU-12LV03 HSU-12HV03 HSU-18LV03 HSU-22LV03 HSU-24LV03 1 2 OUTLET INLET 3 CONNECTING PIPING AND ELECTRICAL WIRING 4 DRAIN HOSE 5 Parts and Functions 15 8 9 10 11 12 13 14 1 SWING 11. FAN SPEED display 16 17 18 19 20 TEMP LOW MED HI AUTO 21 22 FAN 13. Operation mode display Operation mode Remote controller AUTO COOL DRY HEAT FAN ON OFF 2 MODE HEALTH AIRFLOW SLEEP 23 24 HEALTH 3 FRESH 4 CLOCK SET 25 31 26 27 28 5 TIMER STERILIZE 6 7 RESET CODE LIGHT LOCK 30 29 1. RESET When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal 8. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears. LIGHT button Colorful display bar of the controlling indoor machine is on and extinguished. CODE Used to select CODE A or B with a press, A or B will be displayed on LCD. FRESH button Used to set FRESH AIR operation. 31 NOTE: (1)The following functions and related displays are not available , , and (2) Cooling only unit do not have functions and displays related with heating. . 6 Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: 1. Press CLOCK button, "AM" or "PM" flashes. TIMER MODE HEALTH AIRFLOW SLEEP HEALTH FRESH CLOCK SET STERILIZE 2. If the button is kept depressed, time will change quickly. RESET CODE LIGHT LOCK 3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working. Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. [. . . ] For twice press, disappears, the operation stops. AM TEMP SWING ON OFF FAN 3. UV light degerming function Press STERILIZE button , " "and " "displayed on the remote controller and the air conditioning starts the UV light degerming function. " ": For timing operation of UV light degerming function and automatically canceled after 30 minutes' operation. " ": For the long-time running of UV light degerming function. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12HV03




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12HV03 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.