User manual HAIER HSU-12HEK03-R2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-12HEK03-R2. We hope that this HAIER HSU-12HEK03-R2 user guide will be useful to you.


HAIER HSU-12HEK03-R2 : Download the complete user guide (1761 Ko)

You may also download the following manuals related to this product:

   HAIER HSU-12HEK03-R2 (2294 ko)
   HAIER HSU-12HEK03-R2 (2294 ko)
   HAIER HSU-12HEK03-R2 (2294 ko)
   HAIER HSU-12HEK03-R2 (2398 ko)
   HAIER HSU-12HEK03-R2 INSTALLATION (303 ko)

Manual abstract: user guide HAIER HSU-12HEK03-R2

Detailed instructions for use are in the User's Guide.

[. . . ] Note:Cooling only units don't have Drain-elbow The distance between the indoor unit and the floor should be more than 2m. Floor fixing dimensions of the outdoor unit (Unit:mm) Fixing of outdoor unit Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. If vibration may affect the house, fix the unit by attaching a vibration-proof mat. Indoor Unit Selection of Installation Place Outdoor Unit Place, robust not causing vibration, where the body can be supported sufficiently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed. [. . . ] In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. 3 30mm Indoor unit 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Heat insulation material Lid for right piping Lid for under piping Lid for left piping Drain hose Piping Indoor/outdoor electric cable Fix with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. [Other direction piping] Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially. Fixing the indoor unit body Hang surely the unit body onto the upper notches of the mounting plate. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. mounting plate Unloading of indoor unit body When you unload the indoor unit, please use your hand to arise the body to leave agraffe, then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate. agraffe mounting plate 4 Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. If the fuse on PC board is broken please change it with the type of T. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Outdoor unit A 1(N) 2(N) 3(N) 4G0. 75mm2 1(N) 2(N) 3(N) Indoor unit A POWER Power cable: 3G1. 5mm2 { 5 Outdoor unit 1. Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2. Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening torque 18N. m 42N. m Liquid side 6. 35mm(1/4") Spanner Gas side 9. 52mm(3/8") Torque wrench Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. 3. Connection Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. [. . . ] (This must be strictly controlled within 90o and 10 sec. ) 7 1. Power Source Installation The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible. 2. Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. A Liquid side Pipe diameter( 6. 35mm(1/4") 9. 52mm(3/8") 12. 7mm(1/2") ) Size A(mm) 0. 8~1. 5 1. 0~1. 8 1. 2~2. 0 Flare tooling die Gas side Gas side Correct Incorrect Lean Damage of flare Crack Partial Too outside 3. On Drainage Please install the drain hose so as to be downward slope without fail. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12HEK03-R2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12HEK03-R2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.