User manual HAIER HSU-12H03/H

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-12H03/H. We hope that this HAIER HSU-12H03/H user guide will be useful to you.


HAIER HSU-12H03/H : Download the complete user guide (981 Ko)

Manual abstract: user guide HAIER HSU-12H03/H

Detailed instructions for use are in the User's Guide.

[. . . ] Always remember to unplug the air conditioner before openning inlet grill. Inadequate repairs may result in a major source of danger for the user of the air conditioner. Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment. The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon. All these valuable materials may be taken to a waste collecting center and used again after Do not damage any parts of the air adequate recycling. [. . . ] Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key. POWER/SOFT 14 Air Conditioner Edition:2006/1/10 Operation HEALTH operation Remote controller 1. Unit start Press ON/OFF on the remote controller, unit starts. Health function includes health anion function, UV light degerming function. 2. Health anion function Press HEALTH button. (It's available under any mode) POWER/SOFT When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion. BRIEF INTRODUCTION TO HEALTH ANION FUCTION The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. 15 Air Conditioner Edition:2006/1/10 Operation Auto Operation Remote controller 1. Unit start Press ON/OFF on the remote controller, unit starts. 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select DRY operation 3. Select temp. setting Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature. POWER/SOFT 4. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO COOL operation starts when room temp. is higher than temp. setting. Temp. setting+2oC Temp. setting Ultra-low air flow Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp. setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting. 5. Unit stop On reaching temp. setting +2oC unit will run in mild DRY mode. Press ON/OFF button, the unit stops. 18 Air Conditioner Edition:2006/1/10 Operation Fan Operation 1. Unit start Press ON/OFF on the remote controller, unit starts. Remote controller 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select FAN operation 3. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: POWER/SOFT LOW MED HI 4. Unit stop Press ON/OFF button, the unit stops. About FAN operation In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available. 19 Air Conditioner Edition:2006/1/10 Operation Heat Operation 1. Unit start Press ON/OFF on the remote controller, unit starts. Remote controller 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select HEAT operation 3. Select temp. setting Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature. POWER/SOFT 4. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5. Unit stop Press ON/OFF button, the unit stops. 20 Air Conditioner Edition:2006/1/10 Operation Air Flow Direction Adjustment 1. Status display of air sending Vertical flap Pos. 1 Pos. 2 Pos. 3 Pos. 4 POWER/SOFT Pos. 5 Pos. 6 (Auto swing) 2. Up and down air flow direction For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 6 remote controller: : HEAT: remote controller: AUTO: remote controller: Pos. 5 Pos. 4 Pos. 3 Pos. 2 Pos. 1 Pos. 6 Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Pos. 6 The vertical flap will swing according to the above positions Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. 21 Air Conditioner Edition:2006/1/10 Operation Sleep Operation Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. setting so that room temperature won't be too Iow for your sleep. SLEEP operation starts SLEEP operation stops Approx. 6hrs Rises 1OC 1 hr 1 hr Rises 1OC Temp. setting Unit stop In COOL, DRY mode Remote Controller 2. In HEAT mode 1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. [. . . ] When the remote controller is manipulated, it gets the system back to the normal operation mode. 27 Air Conditioner Edition:2006/1/10 Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Proper temperature Do not block the air inlet or outlet Close doors and windows during operation Use the timer effectively During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch. OFF 28 Air Conditioner Edition:2006/1/10 Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance, be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Do not use water, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth. Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping. then wipe off the detergent completely. Do not use the following for cleaning Gasoline, benzine, thinner or cleanser may damage the coating of the unit. Hot water over 40 C(104 F) may cause discoloring or deformation. O O Air Filter cleaning Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. POWER Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects. Once every two weeks Close the inlet grille. 29 Air Conditioner Edition:2006/1/10 Maintenance Replancement of Air Purifying Filter 1. Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward. (use thumbs to push up) 2. Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3. Detach old Air Purifying Filter 4. Attach old Air Purifying Filter Detach old Air Purifying Filter Put air purifying filter appliances into the right and left filter frames . 5. Attach the standard air filter (Necessary installation) Close the Grille surely 6. Close the Inlet Grille NOTE: The air purifying filter of the bacteria-killing medium and the electrostatic air purifying filter accessories with machine will be used based on real situation. The bacteria-killing medium air purifying filter is available for a long time and needn't to be changed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12H03/H




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12H03/H will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.