User manual HAIER HSU-09RR03/R2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-09RR03/R2. We hope that this HAIER HSU-09RR03/R2 user guide will be useful to you.


HAIER HSU-09RR03/R2 : Download the complete user guide (1133 Ko)

You may also download the following manuals related to this product:

   HAIER HSU-09RR03/R2 annexe 1 (546 ko)
   HAIER HSU-09RR03/R2 annexe 2 (1917 ko)

Manual abstract: user guide HAIER HSU-09RR03/R2

Detailed instructions for use are in the User's Guide.

[. . . ] SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner No. 0010518097 IT CONFORMITÀ ALLE DIRETTIVE EUROPEE PER I MODELLI: CE Tutti i prodotti sono conformi alle seguenti normative europee: - Direttiva 73/23/EEC Basso Voltaggio - Direttiva 2006/95/EC Basso Voltaggio - Direttiva 89/336/EEC Compatibilità elettromagnetica - Direttiva 2004/108/EC Compatibilità elettromagnetica ROHS Il prodotto è conforme alla normativa 2002/95/EEC sulla restrizione d'uso di sostanze inquinanti negli apparecchi elettrici ed elettronici. WEEE Informativa al consumatore come previsto dalla normativa europea 2002/96/CE riguardante i rifiuti di apparecchiature elettriche ed elettroniche. SPECIFICHE DI SMALTIMENTO: Il climatizzatore è contrassegnato con questo simbolo, ciò significa che i prodotti elettrici ed elettronici non possono essere smaltiti insieme ai rifiuti domestici non differenziati. Non cercare di demolire il sistema da soli: la demolizioni dei sistemi di condizionamento, nonché il recupero del refrigerante, dell'olio e di qualsiasi altra parte devono essere eseguiti da un installatore qualificato in conformità alla legislazione locale e nazionale vigente in materia. I climatizzatori devo essere trattati presso una struttura specializzata nel riutilizzo, riciclaggio e recupero dei materiali. Il corretto smaltimento del prodotto eviterà le possibili conseguenze negative all'ambiente e alla salute dell'uomo. [. . . ] " " is displayed on the remote controller and " " is displayed on the display board . Air conditioner starts air ionization purify and health anion function operation. For twice press, " " and " "disappear, the operation stops. When indoor fan motor is running, it has air ionization purify and healthy process function. BRIEF INTRODUCTION TO AIR IONIZATION PURIFY AND HEALTH ANION FUCTION 1. The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. 2. The purification function of AIP: DC high voltage bring high voltage electrostatic field, which ionize air into positive and negative ion. a great deal of positive and negative ion adhere to dust passing by, so the dust become "particle with electric charge". so the dust passing by adheres to the AIP board under the force from the electric field, which purifies the unit. 3. When power off, press the purify button, the Remote controller shows "FAN, low, AIP, and negative ion", and the TIMER function is available. 8 Operation Display board 1. Unit start Auto Operation Press ON/OFF on the remote controller, unit starts. Remote controller 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select Auto operation 3. Select temp. setting Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly. Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly. Select a desired temperature. 5 4 4. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5. Unit stop Press ON/OFF button, the unit stops. About Auto Operation Under the mode of auto operation, air conditioner will automatically select Cool or Fan operation according to room temperature. 9 Operation Display board 1. Unit start Cool Operation Remote controller Press ON/OFF on the remote controller, unit starts. 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select COOL operation 3. Select temp. setting Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature. 4. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED HI AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5. Unit stop Press ON/OFF button, the unit stops. 10 Operation Display board 1. Unit start Dry Operation Remote controller Press ON/OFF on the remote controller, unit starts. 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select DRY operation 3. Select temp. setting Press TEMP. [. . . ] inlet grill's top plate 2. Detach the standard air filter Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. AIP(air ionization purify) (bottom frame) 3. Take the VC layer + Bacteria-killing medium sets Take out Take the VC layer or the Bacteria-killing medium sets from the filter. Push the bottom frame of AIP layer, and push up the handle at the same time in order take out the AIP layer board in turns. (AIP board) (Handle) Note:the green aspect of the bacteria-killing medium air purifying filter will face outside, the white aspect will face to the machine. The yellow aspect of the VC layer will face outside, the white aspect will face to the machine. 4. The installation of AIP layer, Bacteria-killing medium sets (must be installed) 5. Close the Inlet Grille Put down the inlet grill's top plate, and close the inlet grill. Common sense: In order to keep the AIP layer having a highly work effect , it should be cleaned regularly or aperiodically just according to the working environment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09RR03/R2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09RR03/R2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.