User manual HAIER HSU-09HRA103

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-09HRA103. We hope that this HAIER HSU-09HRA103 user guide will be useful to you.


HAIER HSU-09HRA103 : Download the complete user guide (548 Ko)

Manual abstract: user guide HAIER HSU-09HRA103

Detailed instructions for use are in the User's Guide.

[. . . ] If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key. DRAIN HOSE Clock set Press CLOCK button, "AM" or "PM" flashes. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working. 4 Load the battery, then put on the cover again. is in line with the " + "/"-"; 2 Operation Base Operation Remote controller Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, the" Pi "sound is heard once, which means the start of this operation. [. . . ] In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode. SOFT Operation You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed automatically takes low speed of AUTO fan mode. Note During POWER operation, in rapid HEAT or COOL mode the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm. Unit stop 1 hr 1 hr Rises 1OC Temp. setting In COOL, DRY mode 2. In HEAT mode 1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. setting. After another 1 hours, temp decrease by 2 OC futher. After more another 3hours, temp. rises by 1OC futher. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won't be too high for your sleep. Temp. setting 1 hr Decreases 2OC 1 hr Decreases 2OC 3 hrs 3 hrs Rises 1 C O To cancel POWER or SOFT operation Press POWER/SOFT button again , POWER or SOFT disappears. The following functions and related displays are not available HSU-09HRA103/R2 HSU-12HRA103/R2 HEALTHY Operation Unit stop Healthy Negative ions SLEEP operation starts SLEEP operation stops In HEAT mode The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. 4 Operation Timer On/Off On-Off Operation Set clock correctly before starting TIMER operation. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS CE All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC ROHS The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive) Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). 4. After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing. 5. Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved. WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Hot water over 40 O C(104O F) may cause discoloring or deformation. During cooling operation prevent the penetration of direct sunlight with curtain or blind Air Filter cleaning Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. If the unit is not to be used for a long time, turn off the power supply main switch. Use the louvers effectively Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects. OFF Once every two weeks Close the inlet grille. Replacement of Air Purifying Filter 1. Open the lnlet Grille Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit. 4. Attach the standard air filter (Necessary installation) ATTENTION: The white side of the photocatalyst air purifying filter face outside, and the black side face the unit The green side of the bacteria-killing medium air purifying filter face outside, and the white side face the unit. 2. Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 5. Close the Inlet Grille Close the Grille surely Detach old Air Purifying Filter NOTE: The photocatalyst air purifying filter will be solarized in fixed time. The bacteria-killing medium air purifying filter will be used for a long time, no need for replacement. But in the period of using them , you should remove the dust frequently by using vacuum cleaner or flaping them lightly, otherwise , its performance will be affected. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it, or its ability of sterilization will be reduced. 3. Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. 6 Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Use an exclusive power source with a circuit breaker Check proper installation of the drainage securely STRICT ENFORCEMENT OFF Connect power supply cord to the outlet completely STRICT ENFORCEMENT Use the proper voltage STRICT STRICT ENFORCEMENT ENFORCEMENT Take care not to damage Do not use power supply the power supply cord. [. . . ] If the fuse of outdoor unit is broken, change it with the type of T. 25A/250V 4. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. Please employ the proper power plug, which fit into the power supply cord. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09HRA103




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09HRA103 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.