User manual HAIER HSU-07CG03R1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-07CG03R1. We hope that this HAIER HSU-07CG03R1 user guide will be useful to you.


HAIER HSU-07CG03R1 : Download the complete user guide (3043 Ko)

Manual abstract: user guide HAIER HSU-07CG03R1

Detailed instructions for use are in the User's Guide.

[. . . ] Then, it will become normal. 5 Operation Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter. A SW ING MP TE ON F OF MO DE CLO CK FAN TIM ER SLE EP RES ET COD E LOC K SET A Loading of the battery Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder) TEMP ON OFF SWING FAN MODE SLEEP Remove the battery cover : CLOCK SET Slightly press " " and push down the cover. TIMER Load the battery : RESET CODE LOCK Be sure that the loading is in line with the " + " / " - " pole request as illustrated. Put on the cover again Confirmation indicator : In disorderation, reload the batteries or load the new batteries after 6 mins. C M O T E O N T R O L U N IT R E M O D E Y L: R -H 05 WITH MIXOLD AND IES 1. DONOT NEWBATTE DONOT OFDIFFERE TOGETHER BATTERIES RRECTLY P O L A R IT Y THE THE NEW BATTERIESAND NOTUSE DIFFERENTTYPES BATTERIES RIES USEBATTER TYPES 2 REMOTE CONTROL UNIT NT MODEL:YR-H05 REMOTE CONTROL UNIT 1. DO NOTMIX OLD Note : Use two new same-typed batteries when loading. [. . . ] COOL About 10o Level Up and down (Use remote controller) Press SWING button, vertical flap will move within the range shown in the Fig. Press SWING button stop it at a fixed position. Left and right air flow adjustment (manual) Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig. About 10o COOL About 45o Cautions: It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur. Cautions: When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right. (6) Unit stop Press ON/OFF button. Vertical flap closes automatically. Cautions: Unit won't restart until 3 minutes have elapsed, due to system protection. Hints As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. It is harmful to your health in summer to go frequently in and out of places where temp. More than this, unit's load can be reduced and power consumption cut down as well. in COOL mode. 9 Operation TIMER operation Set Clock correctly before starting Timer operation(referring to page 5) You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode. Power indicator on indoor unit lights up. A (2)TIMER mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: ON TIMER ON OFF TIMER OFF ON OFF blank TEMP TIMER ON-OFF SWING ON OFF 1 SLEEP FAN Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash. MODE (3)Timer setting Press HOUR button. It can be adjusted within 24 hours. CLOCK SET TIMER 4 3 2 RESET CODE LOCK (4)Confirming your setting After setting correct time, press SET button to confirm, "ON" or "OFF" stops flashing Time displayed: Unit starts or stops at x hour x min. Timer mode indicator on indoor unit lights up. To cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints After replacing batteries or a power failure happens, Time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if timer setting is the same as previous one. 10 Operation TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2) Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: ON TIMER ON OFF TIMER OFF ON OFF blank A TIMER ON-OFF Select TIMER ON-OFF. "ON" will flash. (3)Time setting for TIMER ON Press HOUR button. AM refer's to morning and PM to afternoon. SWING TEMP ON OFF 1 SLEEP FAN MODE CLOCK 3 SET TIMER 6 4 5 LOCK 2 RESET CODE (4) Time confirming for TIMER ON After time setting, press TIMER button to confirm. Time displayed: Unit starts at x hour x min. (5)Time setting for TIMER OFF After time setting, press SET button to confirm, "OFF" stops flashing. Pi"! Removal of the restriction of emergency or test operation: Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the restriction of emergency or test operation to be removed. When the remote controller is manipulated for the removal, then the selected operation by the remote controller. 13 Maintenance Different models have different appearance. Cleaning of unit casing Cut off power supply before cleaning wipe unit casing with soft cloth. squeeze water in the cloth, wipe off the detergent on unit casing completely. Cleaning of remote controller Don't use water to wash unit casing, please use dry cloth. [. . . ] Cause or check points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. (This noise is generated by refrigerant flowing in the system. ) During unit operation, a cracking noise may be heard. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-07CG03R1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-07CG03R1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.