User manual HAIER H2SM-18HA03

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER H2SM-18HA03. We hope that this HAIER H2SM-18HA03 user guide will be useful to you.


HAIER H2SM-18HA03 : Download the complete user guide (12298 Ko)

Manual abstract: user guide HAIER H2SM-18HA03

Detailed instructions for use are in the User's Guide.

[. . . ] Per maggiori informazioni contattare l'installatore o le autorità locali. Le batterie devono essere tolte dal telecomando e smaltite separatamente conformemente alla legislazione locale e nazionale vigente in materia. EN EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS: HSU-07HEA03/R2 HSU-09HEA03/R2 HSU-12HEA03/R2 HSU-18HEA03/R2 HSU-22HEA03/R2 CE All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC - Electromagnetic CompatibilitY 89/336/EEC - Electromagnetic CompatibilitY 2004/108/EC ROHS The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of the council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive). WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. [. . . ] same time. CAUTION PROHIBITION Do not install the unit near a fireplace or other heating apparatus. STRICT ENFORCEMENT Check good condition of the installation stand PROHIBITION Do not pour water onto the unit for cleaning PROHIBITION Do not place animals or plants in the direct path of the air flow PROHIBITION Do not place any objects on or climb on the unit. PROHIBITION Do not place flower vase or water containers on the top of the unit. PROHIBITION PROHIBITION PROHIBITION 4 Parts and Functions Indoor Unit Display board Inlet Air Purifying Filter (inside) Inlet grille Horizontal flap (adjust up and down air flow. Don't adjust it manually) Anion generator (inside) Outlet Air filter(inside) Power plug Vertical blade (adjust left and right air flow) Actual inlet grille may vary from the one shown in the manual according to the product purchased Outdoor Unit OUTLET INLET CONNECTING PIPING AND ELECTRICAL WIRING 4 DRAIN HOSE 5 Parts and Functions Remote controller 1 2 3 4 5 12 MODE SET ON OFF Display board 6 A U T O o C AM PM 7 8 9 10 11 19 20 21 25 1 1 26 4 1 895 ON/OFF TEMP 7. Used to select AUTO run, COOL, DRY and FAN operation 13 FAN TIMER 14 15 16 17 18 SWING CLOCK 15. HOUR Used to select fan speed LO, MED, HI, AUTO Used to set clock and timer setting. Operation mode display Operation mode Remote controller Display board AUTO COOL DRY HEAT FAN 21. Used to select TIMER ON, TIMER OFF, TIMER ON-OFF Used to set correct time 22. HEALTH AUTO LO MED HI Used to reset the controller back to normal condition. Ambient temp. display Clock set When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference. When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working. NOTE: Cooling only unit do not have displays and functions related with heating Hints After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal. 6 Parts and Functions If the unit which you purchased has not healthy function, Remote controller should like the following figure: Remote controller 1 2 3 5 12 MODE SET ON OFF Display board 6 A U T O o C AM PM 7 8 9 10 11 19 20 21 25 1 1 26 1 895 ON/OFF TEMP 7. For each press, fan speed changes as follows: Remote controller: AUTO LO MED HI SLEEP HEALTH LOCK RESET Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. (5) Unit stop Press ON/OFF button, the unit stops. Hints On cooling only unit, heating mode is not available. When starting it next time, just press ON/OFF button and unit will run in previous status. No reelecting is needed. (TIMER ON/OFFSLEEPSWING needs reelecting) 10 Operation Dry Operation (1) Unit start Press ON/OFF button, unit starts. For each press, operation mode changes as follows: AUTO COOL DRY HEAT FAN A U T O ON/OFF TEMP 5 1 MODE 3 3 SET Unit will run in operation mode displayed on LCD. Stop display at your desired mode. 2 FAN TIMER (3) Select temp. setting on LCD. 4 SWING CLOCK SLEEP HEALTH (4) Fan speed selection Press FAN button. For each press, fan speed changes as follows: LOCK RESET AUTO LO MED HI COOL operation starts when room temp. setting. Ultra-low air flow Unit runs at the speed displayed on LCD. In DRY mode, when room temperature becomes lower than temp. setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting. Temp. setting, unit will run in mild DRY mode. (5)Unit stop Press ON/OFF button, the unit stops. [. . . ] Every time the button is pressed, display changes as follows: ON AM OFF PM 12:00 12:00 OFF ON NAM 12:00 TIMER ON-OFF ON PM OFF blank 12:00 ON/OFF TEMP TIMER ON TIMER OFF TIMER ON-OFF Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash. MODE 1 3 3 SET (3)Timer setting Press HOUR / button. It can be adjusted within 24 hours. FAN TIMER 4 SWING 2 CLOCK SLEEP HEALTH LOCK RESET (4)Confirming your setting After setting correct time, press SET button to confirm, "ON" or "OFF" stops flashing Time displayed: Unit starts or stops at x hour x min. Timer mode indicator on indoor unit lights up. To cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints After replacing batteries or a power failure happens, Time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if timer setting is the same as previous one. 17 Operation Timer On-Off Operation (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER H2SM-18HA03




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER H2SM-18HA03 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.