User manual HAIER H2SM-18H03/R2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER H2SM-18H03/R2. We hope that this HAIER H2SM-18H03/R2 user guide will be useful to you.


HAIER H2SM-18H03/R2 : Download the complete user guide (497 Ko)

Manual abstract: user guide HAIER H2SM-18H03/R2

Detailed instructions for use are in the User's Guide.

[. . . ] Installation shall be done by professional people, don't install unit by yourself. Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment. The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon. 1 Cautions For the purpose of the safety, the air conditioner must be properly grounded in accordance with specifications. [. . . ] Then, it will become normal. 6 Operation Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7 m without any obstacle as well. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter. Loading of the battery Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder) Remove the battery cover: Slightly press " " and push down the cover. Load the battery: Be sure that the loading is in line with the" + "/"-" pole request as illustrated. Put on the cover again Confirmation indicator: In disorderation, reload the batteries or load the new batteries after 6 mins. Note: Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key. Power failure resume(please set and apply as necessary) If sudden power failure occurs, the unit will resume original operation when power is supplied again. Note: When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes. 7 Operation Auto run, Fan operation (1) Unit start Press ON/OFF button, unit starts. (Not Timer setting) Power indicator on indoor unit lights up. Enjoy yourself by just a gentle press. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL DRY HEAT FAN Unit will run in selected mode. Stop display at " " AUTO or " "FAN. (3) FAN Press FAN button. For each press, fan speed changes as follows: LO MED HI AUTO (4) Unit stop Unit will run at selected fan speed. Vertical flap closed automatically. Hints Remote controller can memorize settings in each operation mode. Referring to the Fig. COOL About 10 o HEAT About 60o Left and right air flow adjustment Press SWING button, vertical flap will move within (manual) Up and down (Use remote controller) the range shown in the Fig. Press SWING button stop it at a fixed position. Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig. About 10o COOL About 45o HEAT About 60o Cautions: It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur. Cautions: When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right. (6) Unit stop Press ON/OFF button. Vertical flap closes automatically. Cautions: Unit won't restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on cooling only unit. Hints As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation. It is harmful to your health in summer to go frequently in and out of places where temp. More than this, unit's load can be reduced and power consumption cut down as well. in COOL mode. 10 Operation TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2)TIMER mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: ON TIMER ON OFF TIMER OFF ON OFF blank TIMER ON-OFF Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash. (3)Timer setting Press HOUR / button. It can be adjusted within 24 hours. (4)Confirming your setting After setting correct time, press SET button to confirm, "ON" or "OFF" stops flashing Time displayed: Unit starts or stops at x hour x min. [. . . ] Cleaning of the air filter. Once every two weeks Proper temperature Closing of doors and windows during operation Effective use of the timer. Curtains or blinds for windows Avoid time-wasteful operation Never fail to observe the followings Do not sprinkle water over the unit. Do not block the inlet or outlet. Do not pull power plug. Do not use for other purposes. Such as food preservation plant cultivation or animal breeding. 18 Trouble shooting Before asking for service, check the following first. Phenomenon The system does not restart immediately. Cause or check points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER H2SM-18H03/R2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER H2SM-18H03/R2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.