User manual HAIER AS24GS2ERA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER AS24GS2ERA. We hope that this HAIER AS24GS2ERA user guide will be useful to you.


HAIER AS24GS2ERA : Download the complete user guide (3486 Ko)

Manual abstract: user guide HAIER AS24GS2ERA

Detailed instructions for use are in the User's Guide.

[. . . ] Please be subject to the actual produce purchased the above picture is just from your reference When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference. Press the sleep button ten times in five seconds and enter function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote Healthy function is not available for some units. [. . . ] The cancel of the healthy airflow function Press button to enter additional options, Press this button continuously, the louvers location will cycle between in the following three locations again, and then press button to cancel. In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille . This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink, · The filled out label must be adhered in the proximity of the product charging port (e. A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging Before inserting power into receptacle, check the voltage without fail. A receptacle shall be set up in a distance where the power cable can be reached. Place, robust not causing vibration, where the body can be supported sufficiently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed. Place, possible to drain easily, where piping can be connected with the outdoor unit. Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Attention must be paid to the rising up of drain hose The distance between the indoor unit and the floor should be more than 2m. Please be subject to the actual product purchased, the above picture is just for your reference. Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. Find the wall hole location A using a measuring tape In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. Insert the drain hose into the dent of heat insulation materials of indoor unit. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with efrigerant piping by protecting tape. Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole. [. . . ] Do not start or stop the operation by disconnecting the power supply cord and so on. PROHIBITION Do not channel the air flow directly at people, especially at infants or the aged. Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation. Take fresh air occasionally especially when gas appliance is running at the same time. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER AS24GS2ERA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER AS24GS2ERA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.