User manual GTO PRO-SW 6100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GTO PRO-SW 6100. We hope that this GTO PRO-SW 6100 user guide will be useful to you.


GTO PRO-SW 6100 : Download the complete user guide (1619 Ko)

Manual abstract: user guide GTO PRO-SW 6100

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS FOR GTO/PRO SW-5100 and GTO/PRO SW-6100 AC Powered Swing Gate Operators LI US STED WARNING! · READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Stay clear of the unit while it is operating and exercise caution at all times. This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc. DO NOT Install This Operator Without Safety Edges! © 2000 GTO, Inc. [. . . ] The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. MAKE SURE THE OPERATOR POWER IS OFF BEFORE ATTEMPTING TO ADJUST THE LIMIT SWITCHES. Limit Adjustment Lock Lift and release the limit switch plate to unlock the limit nuts (see illustration at right). Using a fingertip, roll the limit nuts along the travel shaft until the correct open and closed gate positions are determined. Limit illustration If the operator is mounted to the LEFT of the gate (seeSwitch Plate below): the left limit switch adjusts the open position. The right limit switch adjusts the closed position. If the operator is mounted to the RIGHT of the gate (see illustration below): the right limit switch adjusts the open position. The left limit switch adjusts the closed position. Lift limit switch plate to release, Test the operator to verify that the limit switches are properly set. After properly setting the limit switches, the control board must be set according to the operator application. The system accessories should also be connected to the control board. Left Limit Nut OPEN position stop ­ if operator is mounted to the LEFT of the gate. CLOSED position stop ­ if operator is mounted to the RIGHT of the gate. Limit Switch Right Limit Nut CLOSED position stop ­ if operator is mounted to the LEFT of the gate. OPEN position stop ­ if operator is mounted to the RIGHT of the gate. Limit Switch Limit Switch Plate Travel Shaft The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. 15 ADVANCED GATE OPERATOR CONTROL BOARD T1SEC JP1 JP2 +300VDC DUAL GATE INTERFACE ­ + ­ STATUS LED RX + 24VDC ACCES. PWR. AUX 2 AUX 1 LOCK 2 LOCK 1 ­ TX + QC1 QC2 GRN GTO RED RCVR. BLK BATT1 EDGE 6 EDGE 5 EDGE 4 (Not Actual Size) BATT­ BATT TEMP EDGE 3 LEARN/RESET CLS. SENS. F1 Replace with 1/2 Amp Max PWR OK TIMER ON OBSTRUCT MIN MAX EDGE 2 EDGE 1 T1-P-CT OPN. LIM SW ERR. MIN MAX OPEN INERTIA TIMER FIRE DEPT. GTO MODEM 1 2 3 4 5 OPEN MTR. LOOP COMPUTER RS-232 BATT SW 24AC 24CT 24AC SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN COMP/MODEM 6 7 8 ENTRY ENAB ON ENTRY LOOP FREE EXIT CYCLE GTO Inc. , Tallahassee, FL 16 CONTROL BOARD SETTINGS LEARN/RESET: THESE SETTINGS SHOULD BE ADJUSTED ONLY BY AN EXPERIENCED INSTALLER OR TECHNICIAN! 1) Use to set transmitter code in control board memory. 2) Press this button to clear the diagnostic and error LEDs. LEARN/RESET ON SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN COMP/MODEM GTO Inc. , Tallahassee, FL SWNG/SLD (swing or slide gate operation): SWNG = swing gate SLD = slide gate [factory default is SWNG]. MAST/SLV (master or slave unit): This DIP switch must be set to MAST for single gate applications. For dual gate applications set one control board to MAST and the other to SLD [factory default is MAST]. GATE R/L (gate opens right or left): The direction a gate opens is determined by standing inside the property and facing toward the gate. SEQUENCE 1: This DIP switch is used for sequencing swing gates [factory default is OFF]. [. . . ] The warranty period for residential installations is five (5) years for mechanical parts; three (3) years for electronic components. The warranty period for commercial installations is three (3) years for mechanical parts; two (2) years for electronic components. In the case of product failure due to defective material or manufacturer workmanship within the warranty period, the operator will be repaired or replaced (at manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, Inc. , 3121 Hartsfield Road, Tallahassee, Florida 32303. IMPORTANT: Call (850) 575-0176 or Fax (850) 5758950 for a Return Goods Authorization (RGA) number before returning to factory. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SW 6100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SW 6100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.