[. . . ] INSTALLATION INSTRUCTIONS FOR
GTO/PRO SW-5100 and GTO/PRO SW-6100 AC Powered Swing Gate Operators
LI
US
STED
WARNING!
· READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Stay clear of the unit while it is operating and exercise caution at all times.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
DO NOT Install This Operator Without Safety Edges!
© 2000 GTO, Inc. [. . . ] The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. MAKE SURE THE OPERATOR POWER IS OFF BEFORE ATTEMPTING TO ADJUST THE LIMIT SWITCHES.
Limit Adjustment Lock
Lift and release the limit switch plate to unlock the limit nuts (see illustration at right). Using a fingertip, roll the limit nuts along the travel shaft until the correct open and closed gate positions are determined.
Limit illustration If the operator is mounted to the LEFT of the gate (seeSwitch Plate below): the left limit switch adjusts the open position. The right limit switch adjusts the closed position.
If the operator is mounted to the RIGHT of the gate (see illustration below): the right limit switch adjusts the open position. The left limit switch adjusts the closed position.
Lift limit switch plate to release,
Test the operator to verify that the limit switches are properly set. After properly setting the limit switches, the control board must be set according to the operator application. The system accessories should also be connected to the control board.
Left Limit Nut
OPEN position stop if operator is mounted to the LEFT of the gate. CLOSED position stop if operator is mounted to the RIGHT of the gate. Limit Switch
Right Limit Nut
CLOSED position stop if operator is mounted to the LEFT of the gate. OPEN position stop if operator is mounted to the RIGHT of the gate.
Limit Switch
Limit Switch Plate
Travel Shaft
The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close.
15
ADVANCED GATE OPERATOR CONTROL BOARD
T1SEC JP1 JP2
+300VDC
DUAL GATE INTERFACE
+
STATUS LED
RX
+
24VDC
ACCES. PWR.
AUX 2
AUX 1
LOCK 2
LOCK 1
TX
+
QC1
QC2
GRN GTO RED RCVR. BLK
BATT1
EDGE 6
EDGE 5
EDGE 4
(Not Actual Size)
BATT BATT TEMP
EDGE 3
LEARN/RESET
CLS. SENS.
F1 Replace with 1/2 Amp Max PWR OK TIMER ON OBSTRUCT
MIN MAX
EDGE 2
EDGE 1
T1-P-CT
OPN. LIM SW ERR.
MIN
MAX
OPEN
INERTIA
TIMER
FIRE DEPT.
GTO MODEM
1 2 3 4 5
OPEN MTR. LOOP
COMPUTER RS-232
BATT SW 24AC 24CT 24AC
SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN COMP/MODEM
6 7 8
ENTRY ENAB
ON
ENTRY LOOP
FREE EXIT
CYCLE
GTO Inc. , Tallahassee, FL
16
CONTROL BOARD SETTINGS
LEARN/RESET:
THESE SETTINGS SHOULD BE ADJUSTED ONLY BY AN EXPERIENCED INSTALLER OR TECHNICIAN!
1) Use to set transmitter code in control board memory. 2) Press this button to clear the diagnostic and error LEDs.
LEARN/RESET
ON
SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN COMP/MODEM
GTO Inc. , Tallahassee, FL
SWNG/SLD (swing or slide gate operation): SWNG = swing gate SLD = slide gate [factory default is SWNG]. MAST/SLV (master or slave unit): This DIP switch must be set to MAST for single gate applications. For dual gate applications set one control board to MAST and the other to SLD [factory default is MAST]. GATE R/L (gate opens right or left): The direction a gate opens is determined by standing inside the property and facing toward the gate. SEQUENCE 1: This DIP switch is used for sequencing swing gates [factory default is OFF]. [. . . ] The warranty period for residential installations is five (5) years for mechanical parts; three (3) years for electronic components. The warranty period for commercial installations is three (3) years for mechanical parts; two (2) years for electronic components. In the case of product failure due to defective material or manufacturer workmanship within the warranty period, the operator will be repaired or replaced (at manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, Inc. , 3121 Hartsfield Road, Tallahassee, Florida 32303. IMPORTANT: Call (850) 575-0176 or Fax (850) 5758950 for a Return Goods Authorization (RGA) number before returning to factory. [. . . ]