User manual GTO PRO-SW 50006000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GTO PRO-SW 50006000. We hope that this GTO PRO-SW 50006000 user guide will be useful to you.


GTO PRO-SW 50006000 : Download the complete user guide (917 Ko)

Manual abstract: user guide GTO PRO-SW 50006000

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS FOR GTO/PRO SW-5000 and GTO/PRO SW-6000 AC Powered Swing Gate Operators LI US STED WARNING! · READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Stay clear of the unit while it is operating and exercise caution at all times. This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc. DO NOT Install This Operator Without Safety Edges! © 2000 GTO, Inc. [. . . ] square area Opened Gate 15" center to center mounting holes Mounting the Operator 1. 2. 15. 875" center to center mounting holes Lift the operator and align its mounting holes over the 1/2" diameter concrete mounting anchors. Lower the operator into position and fasten it to the mounting anchors with (4) 1/2" washers and nuts (not provided). Place the spline retainer on top of the upper spline and fasten it with the 3/8" spline retainer bolt. Step down on foot pedal to disengage the lower and upper splines (see illustrations on page 1 and 10). 13 3. Connecting the Gate Arm Assembly 1. Fit the end of the reducer arm on the end of the upper spline (see illustration at right). Align the bolt holes of the parts and join them with (1) 1/2" bolt. Fit the ends of the reducer arm, stop bracket and gate arm together (see illustration). Align the bolt holes of the parts and join them with (1) 1/2" bolt and (1) Nyloc nut. 1/2" x 1-1/2" bolts Upper Spline 1/2" x 1-1/2" bolts Reducer Arm 1/2" x 2" bolt 1/2" x 2-1/2" bolt Gate Arm Adjusting Bracket 1/2" nuts and washers Gate Arm 1/2" nuts and washers Nyloc Nut Gate Bracket Stop Bracket Nyloc Nut Arm Layout For Gate Hinged on Inside Left To prevent hands and fingers from being pinched, fasten the knuckle cover over the knuckle joint of the gate arm with (2) 1/2" x 1" bolts. NOTE: Make sure warning decals (2) are affixed to the knuckle cover. P ! in R Et Gn N o i ds A P Ha n D h ee p r RB3 465 c Ka le C 3. Attach the adjusting bracket to the gate arm with (2) 1/2" bolts, nuts, and washers. Attach the gate bracket to the end of the adjusting bracket with (1) bolt and (1) Nyloc nut. 4. 1/2" 5. Pivot the gate arm assembly toward the gate until it is fully extended. Using the height of the level gate arm assembly as a reference, clamp a support bar (not provided) for the gate bracket to the gate. Attach the gate bracket to the support bar with (2) 1/2" bolts, lock washers, and nuts (not provided). Swing the gate through its full operating arc to verify that the gate arm retracts and extends without binding. Opening and closing the gate in this manner will also test the clearance between the gate and the operator. Permanently bolt or weld the support bar to the gate once its correct position has been determined. Connecting Power to the Operator Have a licensed electrician run 115 Vac wiring into a Field Wiring Connection Compartment (ON/OFF) box. The circuit must be protected with a 15 A main disconnect breaker (not provided). NOTE: Power and wiring connections MUST be installed by a licensed electrician in accordance with NEC (National Electric Code) and local codes. NEVER run low voltage (e. g. , accessory or receiver) wires in conduit containing 115 Vac wiring. After the gate operator is connected to the 115 Vac power supply, the limit switches can be set. See ADJUSTING THE LIMIT SWITCHES on the next page. 14 ADJUSTING THE LIMIT SWITCHES The limit switches determine how far the gate travels to open and close. The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. [. . . ] The warranty period for residential installations is five (5) years for mechanical parts; three (3) years for electronic components. The warranty period for commercial installations is three (3) years for mechanical parts; two (2) years for electronic components. In the case of product failure due to defective material or manufacturer workmanship within the warranty period, the operator will be repaired or replaced (at manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, Inc. , 3121 Hartsfield Road, Tallahassee, Florida 32303. IMPORTANT: Call (850) 575-0176 or Fax (850) 5758950 for a Return Goods Authorization (RGA) number before returning to factory. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SW 50006000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SW 50006000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.