User manual GTO PRO-SW 4200XL SLAVE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GTO PRO-SW 4200XL SLAVE. We hope that this GTO PRO-SW 4200XL SLAVE user guide will be useful to you.


GTO PRO-SW 4200XL SLAVE : Download the complete user guide (2111 Ko)

Manual abstract: user guide GTO PRO-SW 4200XL SLAVE

Detailed instructions for use are in the User's Guide.

[. . . ] for installing the GTO/PRO SW-4200 with the GTO/PRO SW-4000 in a dual application DC-SERIES Installation Manual ® DC-SERIES ® FOR PROFESSIONAL INSTALLATION ONLY! This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. [. . . ] If the wires are connected incorrectly, the control board will be damaged. NEVER insert the battery with the terminals to the left. BLACK wire to NEGATIVE (--) terminal RED wire to POSITIVE (+) terminal BLACK RED Connecting Operator Power Cables Step 3 12 V Battery (Included) Strip approximately 3/16" of insulation from each wire of the power cable. Twist each exposed wire tightly (there are seven [7] wires inside the power cable sheath). Thread approximately 6" of the power cable into the control box and retighten sealing nut until the power cable locks into place. 15 FUSE SWITCH GTO, Inc. 3121 Hartsfield Rd Tallahassee, FL 32303 ALARM BAT­ www. gtoinc. com 800-543-GATE BAT+ DUAL ON MODES 1 1234 2 3 4 ON OFF SET LIMIT MODES ON 1 1 2 3 4 5 6 7 ON 2 3 4 5 6 7 OFF LEARN TRANSMITTER SWITCH 10' 12' 14' 8' GATE LENGTH 16' Strain Relief CYCLE CLOSE CLOSE EDGE SLAVE INPUTS MASTER INPUTS EXIT/ OPEN OPEN EDGE GRN WHT BLUE BRN ORG RED BLK GRN WHT BLUE BRN ORG RED BLK COM COM SHADOW LOOP SAFETY Lock Nut Hub Sealing Nut ~~ 18VAC ­ + NC RLY-COM NO SOLAR RELAY OUT GRN BLK RECEIVER RED Strain Relief Operator Power Cable 20 MASTER Operator Step 4 Insert the stripped power cable wires into the appropriate terminals on the MASTER OPERATOR terminal block. The green wire should be inserted into the GRN terminal, the blue wire into BLU, the orange wire into ORG, black wire into BLK, and the red wire into the RED terminal. A dab of petroleum jelly on each terminal will help prevent corrosion. Correct Wrong Wrong SWITCH GRN WHT MASTER INPUTS J13 J5 BLUE BRN ORG RED BLK Power cable from MASTER operator arm CYCLE CLOSE SAFETY EXIT OPEN SHADOW LOOP CLOSE EDGE OPEN EDGE COM COM GRN J11 J8 MIN STALL FORCE Wire Terminal Block Wire Terminal Block Wire Terminal Block SLAVE Operator Step 5 Review the Installation Overview illustration on page 12 before proceeding. Cut a slot into the driveway to accommodate PVC conduit (not provided). The buried conduit will protect the 40 foot power cable from automobile tires, lawn mower blades, weed eaters, and grazing animals. Pull the 40 foot second operator power cable through the conduit and secure them into the slot in the driveway. Step 6 Strip approximately 3/16" of insulation from each wire of the 50 foot power cable. Insert the second operator power cable upward through the right strain relief (if necessary, loosen the sealing nut). Retighten strain relief (on the black sheath of the power cable) until the power cable locks into place. Insert the stripped wires of the power cable into the appropriate terminals on the SLAVE OPERATOR terminal block. The green wire should be inserted into the GRN terminal, the blue wire into BLU, the orange wire into ORG, black wire into BLK, and the red wire into the RED terminal. Tighten the set screws against the end of the wires. Power Cable from the SLAVE operator arm GRN 21 MAX RECEIVER J12 BLK RED WHT SLAVE INPUTS MASTER INPUTS J6 J21 SWITCH BLUE BRN ORG RED BLK GRN WHT BLUE BRN ORG J13 J5 RED BLK Powering the System IMPORTANT: · · Installation of the Transformer The transformer is designed and intended for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover or housing (available at local electrical supply stores) must be used. All low voltage wire used with the GTO/PRO® 4000/4200 Gate Operator must be 16 gauge dual conductor, multi-stranded, direct burial wire (see page 23 and the Accessory Catalog). from an ac power source, you will need to use from 10 to 30 watts of solar charging power to charge the battery (see Accessory Catalog). Refer to the Solar Panel and Gate Activity chart below. · OPTIONAL Solar Panel and Gate Activity The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 15 to 30 watts of solar charging power. The figures shown are for winter (minimum sunlight) and do not account for the use of any accessory items. Accessories connected to your system will draw additional power from the battery. NOTE: A minimum of 15 watts of solar charging power is required for GTO/PRO 4000/4200 dual gate systems, with a maximum of 30 watts. [. . . ] Key Chain Mini Transmitter (RB744) The Key Chain Mini Transmitter is a miniature version of the GTO/PRO® entry transmitter and has the same adjustable code settings. Entry Transmitter (RB741) The GTO/PRO® entry transmitter, with adjustable code settings, is standard equipment with all GTO/PRO® systems. Digital Keypad (F300) The specially designed digital keypad can be easily installed as a wireless or wired keypad. It can be programmed to use up to fifteen different personal identification number (PIN) codes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SW 4200XL SLAVE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SW 4200XL SLAVE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.