User manual GTO PRO-SW 3000XL MASTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GTO PRO-SW 3000XL MASTER. We hope that this GTO PRO-SW 3000XL MASTER user guide will be useful to you.


GTO PRO-SW 3000XL MASTER : Download the complete user guide (1393 Ko)

Manual abstract: user guide GTO PRO-SW 3000XL MASTER

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Manual for the DC-SERIES ® DC-SERIES ! ® WARNING Can Cause Injury or Death MOVING GATE 1-800-543-GATE (4283) · www. gtopro. com SINGLE Gate Operator System FOR PROFESSIONAL INSTALLATION ONLY! WARNING! This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. [. . . ] · The operator is level and mounted on the centerline of the gate. C L Closed Position Stop Plate Gate In Closed Position Mounting the Control Box 15 ALARM BAT­ BAT+ 800-543-GATE www. gtoinc. com Step 13 Mount the control box using the screws (provided) or another secure mounting method. The control box must be mounted at least 3 feet above the ground to protect it from rain splash, snow, etc. , and at least 3 feet from an AC power source to prevent electrical interference. Use mounting holes and screws provided to mount control box to a secure surface. FUSE SWITCH GTO, Inc. 3121 Hartsfield Rd Tallahassee, FL 32303 1234 DUAL ON MODES 1 2 3 4 ON OFF SET LIMIT MODES ON 1 1 2 3 4 5 6 7 ON 2 3 4 5 6 7 OFF LEARN TRANSMITTER SWITCH 10' 12' 14' 8' GATE LENGTH 16' ~~ 18VAC ­ + NC RLY-COM NO SOLAR RELAY OUT SHADOW LOOP SAFETY CYCLE CLOSE EXIT/ OPEN SLAVE INPUTS MASTER INPUTS OPEN EDGE GRN WHT BLUE BRN ORG RED BLK GRN WHT BLUE BRN ORG RED BLK COM COM CLOSE EDGE GRN BLK RED RECEIVER NOTE: The battery that came with your GTO/PRO® 3000 , MUST be placed horizontally battery with the terminals on the RIGHT. If an optional second battery is needed, both batteries must be placed vertically with terminals at the bottom. An optional second battery can be used for solar and/or high traffic applications, if needed. . Single Battery Installed Horizontally with terminals on the right. Dual Batteries Installed Vertically with terminals on bottom. 17 Connecting Operator Power Cable Step 14 Make sure the control box power switch is in the OFF position. Remove the control box cover and slide the battery into position with its terminals to the RIGHT (see illustration). Connect the BLACK battery wire to the NEGATIVE (­) battery terminal. If the wires are connected incorrectly, the control board may be damaged. NEVER insert the battery with the terminals to the left. BLACK wire to NEGATIVE (--) terminal RED wire to POSITIVE (+) terminal BLACK RED 12 V Battery (Included) Step 15 Strip approximately 3/16" of insulation from each wire of the operator power cable. Twist each exposed wire tightly (there are seven [7] wires inside the power cable sheath). Thread approximately 6" of the power cable into the control box and retighten sealing nut until the power cable locks into place. 15 FUSE SWITCH GTO, Inc. 3121 Hartsfield Rd Tallahassee, FL 32303 ALARM BAT­ BAT+ 800-543-GATE www. gtoinc. com 1234 DUAL ON MODES 1 2 3 4 ON OFF SET LIMIT MODES ON 1 1 2 3 4 5 6 7 ON 2 3 4 5 6 7 OFF LEARN TRANSMITTER SWITCH 10' 12' 14' 8' GATE LENGTH 16' ~~ 18VAC ­ + NC RLY-COM NO SOLAR RELAY OUT SHADOW LOOP SAFETY CYCLE CLOSE EXIT/ OPEN SLAVE INPUTS MASTER INPUTS OPEN EDGE GRN WHT BLUE BRN ORG RED BLK GRN WHT BLUE BRN ORG RED BLK COM COM CLOSE EDGE GRN BLK RED RECEIVER Strain Relief Lock Nut Hub SWITCH Sealing Nut Strain Relief GRN WHT BLUE BRN ORG Operator Power Cable J13 MASTER INPUTS Step 16 Insert the stripped operator power cable wires into the appropriate terminals on the OPERATOR terminal block. The green wire should be inserted into the GRN terminal, the blue wire into BLU, the orange wire into ORG, black wire into BLK, and the red wire into the RED terminal. A dab of petroleum jelly on each terminal will help prevent corrosion. Do not overtighten. RED J5 BLK Power cable from operator (master) arm CYCLE CLOSE SAFETY EXIT OPEN SHADOW LOOP CLOSE EDGE OPEN EDGE COM COM GRN J11 J8 MIN STALL FORCE RECEIVER Correct Wrong Wrong J12 Wire Terminal Block Wire Terminal Block Wire Terminal Block 18 MAX BLK RED Powering the System Installation of the Transformer IMPORTANT: · The transformer is designed and intended for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover or housing (available at local electrical supply stores) must be used. All low voltage wire used with the GTO/PRO® 3000 Gate Operator must be 16 gauge dual conductor, multi-stranded, direct burial wire (see page 20) and the Accessory Catalog). from an ac power source, you will need to use at least one 5 watt Solar Panel to charge the battery (see Accessory Catalog). Refer to the Solar Panels and Gate Activity chart below. · · Optional Solar Panels and Gate Activity The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 5 to 30 watts of solar charging power. The figures shown are for winter (minimum sunlight) and do not account for the use of any accessory items. Accessories connected to your system will draw additional power from the battery. NOTE: A maximum of 30 watts of solar charging power can be connected to the GTO/ PRO® Gate Operator. [. . . ] Wires directly to the control board and uses 16 gauge multi-stranded, dual conductor low voltage wire (sold separately). Pin Lock (RB975) The Pin Lock substitutes for the clevis pin at the front end of the GTO/PRO® 3200 gate operator. Helps prevent theft of the operator from the gate, while allowing quick release of the operator. Key Chain Mini Transmitter (RB744) The Key Chain Mini Transmitter is a miniature version of the GTO/PRO® 3200 entry transmitter and has the same adjustable code settings. 12 Volt battery included. Entry Transmitter (RB741) The GTO/PRO® entry transmitter, with adjustable code settings, is standard equipment with all GTO/PRO® 3200 systems. 9 Volt battery included. Digital Keypad (F300) 1 4 7 2 5 8 0 3 6 9 The specially designed digital keypad can be easily installed as a wireless or wired keypad. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SW 3000XL MASTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SW 3000XL MASTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.