[. . . ] INSTALLATION INSTRUCTIONS FOR
GTO/PRO SL-5100 and GTO/PRO SL-6100 Advanced AC Powered Slide Gate Operators
LI
US
STED
WARNING!
· READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Stay clear of the unit while it is operating and exercise caution at all times.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
DO NOT Install This Operator Without Roller Guards And Safety Edges!
© 2000 GTO, Inc. [. . . ] 2.
2.
3.
11
4.
Chain adjuster bolts: adjust outside nut until desired chain tension is achieved. Release foot pedal to re-engage chain sprocket.
5.
Chain Bracket
Sprocket
Chain Bracket
Roller Guides
!
WARNING
· Fingers, hands, and loose clothing may be dragged into chain sprockets. · Keep hands, fingers, and loose clothing away from chain and sprockets.
Chain
slack (1" for every 10' of chain)
Gate
Chain Bracket and Adjustment Bolt (included)
Chain (included)
Master Link (included)
Connecting Power to the Operator
Have a licensed electrician run 115 Vac wiring into a Field Wiring Connection Compartment (ON/OFF) box. The circuit must be protected with a 15 A main disconnect breaker (not provided). NOTE: Power and wiring connections MUST be installed by a licensed electrician in accordance with NEC (National Electric Code) and local codes. NEVER run low voltage (e. g. , accessory or receiver) wires in conduit containing 115 Vac wiring.
After the gate operator is connected to the 115 Vac power supply, the limit switches can be set. See ADJUSTING THE LIMIT SWITCHES on the next page.
12
ADJUSTING THE LIMIT SWITCHES
The limit switches determine how far the gate travels to open and close. The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. MAKE SURE THE OPERATOR POWER IS OFF BEFORE ADJUSTING THE LIMIT SWITCHES. Lift and release the limit switch plate to unlock the limit nuts (see illustration at right). Using a fingertip, roll the limit nuts along the travel shaft until the correct open and closed gate positions are determined. If the gate opens from LEFT to RIGHT (see illustration below): the right limit switch adjusts the closed position. If the gate opens from RIGHT to LEFT (see illustration below): the left limit switch adjusts the closed position. The right limit switch adjusts the open position.
Limit Adjustment Lock
Limit Switch Plate
Test the operator to verify that the limit switches are properly set. After properly setting the limit switches, the control board must be set according to the operator application. The system accessories should also be connected to the control board.
Lift limit switch plate to release, then adjust limit nut.
Left Limit Nut
OPEN position stop if gate opens LEFT to RIGHT CLOSED position stop if gate opens RIGHT to LEFT
Right Limit Nut
CLOSED position stop if gate opens LEFT to RIGHT OPEN position stop if gate opens RIGHT to LEFT
Limit Switch
Limit Switch
Limit Switch Plate
Travel Shaft
The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close.
13
ADVANCED GATE OPERATOR CONTROL BOARD
T1SEC JP1 JP2
+300VDC
DUAL GATE INTERFACE
+
STATUS LED
RX
24VDC
ACCES. PWR.
+ AUX 2 ALARM LOCK 2
LOCK 1
TX
+
QC1
QC2
GRN GTO RED RCVR. BLK
DANGER
HIGH VOLTAGE
400 Volts DC for 5 minutes after power is turned off!
EDGE 6
EDGE 5
EDGE 4
(Not Actual Size)
BATT BATT TEMP T1-P-CT F1 Replace with 1/2 Amp Max
EDGE 3
LEARN/RESET
CLS. INTERN. ERR.
MIN MAX 1
MIN
MAX
COM
OPEN
INERTIA
TIMER
120
FIRE DEPT. LOOP
GTO Inc. , Tallahassee, FL
SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN OPEN/CLOSE
1 2 3 4 5 6 7 8
SAFETY LOOP COM ENTRY LOOP
ON
FREE EXIT COM
CYCLE
BATT
SW
24AC
24CT 24AC
14
CONTROL BOARD SETTINGS
THESE SETTINGS SHOULD BE ADJUSTED ONLY BY AN EXPERIENCED INSTALLER OR TECHNICIAN!2) Press this button to clear the diagnostic and error LEDs.
LEARN/RESET
ON
SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. [. . . ] The warranty period for residential installations is five (5) years for mechanical parts; three (3) years for electronic components. The warranty period for commercial installations is three (3) years for mechanical parts; two (2) years for electronic components. In the case of product failure due to defective material or manufacturer workmanship within the warranty period, the operator will be repaired or replaced (at manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, Inc. , 3121 Hartsfield Road, Tallahassee, Florida 32303. IMPORTANT: Call (850) 575-0176 or Fax (850) 5758950 for a Return Goods Authorization (RGA) number before returning to factory. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SL 51006100
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SL 51006100 will begin.