User manual GTO PRO-SL 51006100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GTO PRO-SL 51006100. We hope that this GTO PRO-SL 51006100 user guide will be useful to you.


GTO PRO-SL 51006100 : Download the complete user guide (1261 Ko)

Manual abstract: user guide GTO PRO-SL 51006100

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS FOR GTO/PRO SL-5100 and GTO/PRO SL-6100 Advanced AC Powered Slide Gate Operators LI US STED WARNING! · READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Stay clear of the unit while it is operating and exercise caution at all times. This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc. DO NOT Install This Operator Without Roller Guards And Safety Edges! © 2000 GTO, Inc. [. . . ] 2. 2. 3. 11 4. Chain adjuster bolts: adjust outside nut until desired chain tension is achieved. Release foot pedal to re-engage chain sprocket. 5. Chain Bracket Sprocket Chain Bracket Roller Guides ! WARNING · Fingers, hands, and loose clothing may be dragged into chain sprockets. · Keep hands, fingers, and loose clothing away from chain and sprockets. Chain slack (1" for every 10' of chain) Gate Chain Bracket and Adjustment Bolt (included) Chain (included) Master Link (included) Connecting Power to the Operator Have a licensed electrician run 115 Vac wiring into a Field Wiring Connection Compartment (ON/OFF) box. The circuit must be protected with a 15 A main disconnect breaker (not provided). NOTE: Power and wiring connections MUST be installed by a licensed electrician in accordance with NEC (National Electric Code) and local codes. NEVER run low voltage (e. g. , accessory or receiver) wires in conduit containing 115 Vac wiring. After the gate operator is connected to the 115 Vac power supply, the limit switches can be set. See ADJUSTING THE LIMIT SWITCHES on the next page. 12 ADJUSTING THE LIMIT SWITCHES The limit switches determine how far the gate travels to open and close. The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. MAKE SURE THE OPERATOR POWER IS OFF BEFORE ADJUSTING THE LIMIT SWITCHES. Lift and release the limit switch plate to unlock the limit nuts (see illustration at right). Using a fingertip, roll the limit nuts along the travel shaft until the correct open and closed gate positions are determined. If the gate opens from LEFT to RIGHT (see illustration below): the right limit switch adjusts the closed position. If the gate opens from RIGHT to LEFT (see illustration below): the left limit switch adjusts the closed position. The right limit switch adjusts the open position. Limit Adjustment Lock Limit Switch Plate Test the operator to verify that the limit switches are properly set. After properly setting the limit switches, the control board must be set according to the operator application. The system accessories should also be connected to the control board. Lift limit switch plate to release, then adjust limit nut. Left Limit Nut OPEN position stop ­ if gate opens LEFT to RIGHT CLOSED position stop ­ if gate opens RIGHT to LEFT Right Limit Nut CLOSED position stop ­ if gate opens LEFT to RIGHT OPEN position stop ­ if gate opens RIGHT to LEFT Limit Switch Limit Switch Limit Switch Plate Travel Shaft The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. 13 ADVANCED GATE OPERATOR CONTROL BOARD T1SEC JP1 JP2 +300VDC DUAL GATE INTERFACE ­ + ­ STATUS LED RX 24VDC ACCES. PWR. + AUX 2 ALARM LOCK 2 LOCK 1 ­ TX + QC1 QC2 GRN GTO RED RCVR. BLK DANGER HIGH VOLTAGE 400 Volts DC ­ for 5 minutes after power is turned off! EDGE 6 EDGE 5 EDGE 4 (Not Actual Size) BATT­ BATT TEMP T1-P-CT F1 Replace with 1/2 Amp Max EDGE 3 LEARN/RESET CLS. INTERN. ERR. MIN MAX 1 MIN MAX COM OPEN INERTIA TIMER 120 FIRE DEPT. LOOP GTO Inc. , Tallahassee, FL SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN OPEN/CLOSE 1 2 3 4 5 6 7 8 SAFETY LOOP COM ENTRY LOOP ON FREE EXIT COM CYCLE BATT SW 24AC 24CT 24AC 14 CONTROL BOARD SETTINGS THESE SETTINGS SHOULD BE ADJUSTED ONLY BY AN EXPERIENCED INSTALLER OR TECHNICIAN!2) Press this button to clear the diagnostic and error LEDs. LEARN/RESET ON SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. [. . . ] The warranty period for residential installations is five (5) years for mechanical parts; three (3) years for electronic components. The warranty period for commercial installations is three (3) years for mechanical parts; two (2) years for electronic components. In the case of product failure due to defective material or manufacturer workmanship within the warranty period, the operator will be repaired or replaced (at manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, Inc. , 3121 Hartsfield Road, Tallahassee, Florida 32303. IMPORTANT: Call (850) 575-0176 or Fax (850) 5758950 for a Return Goods Authorization (RGA) number before returning to factory. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SL 51006100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SL 51006100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.