[. . . ] INSTALLATION INSTRUCTIONS FOR
GTO/PRO SL-5000 and GTO/PRO SL-6000 AC Powered Slide Gate Operators
LI
US
STED
WARNING!
· READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Stay clear of the unit while it is operating and exercise caution at all times.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
DO NOT Install This Operator Without Roller Guards And Safety Edges!
© 2000 GTO, Inc. [. . . ] You must use (4) 1/2" diameter mounting anchors, washers, and nuts (not included) to mount the operator on the pad. Lay the mounting template on the level concrete pad and mark the pad according to the instructions on the template. Before mounting the operator, check the following:
· · ·
The concrete pad is level. Four (4) 1/2" diameter mounting anchors are in their correct positions. Conduit for power and accessory wiring is installed.
Installation Alignment
Driveway Fence Post C L
Safety Edges
(REQUIRED)
Gate 4" to 6"
(REQUIRED)
Safety Edge
Fence Post Roller Safety Edge
(REQUIRED)
Chain Bracket
Chain brackets must be installed (welded or bolted) to provide 4 to 6 inches between chain and inside of gate. This will insure adequate clearance between the operator housing and the gate.
Roller
Operator must be mounted with the chain rollers and sprocket aligned with the chain.
Pad mounting holes line up with chain idler wheels and should be no closer than 4 inches and no futher than 6 inches from the gate.
7" center to center mounting holes
1811/16" center to center mounting holes
Use 1/2" dia. concrete mounting bolts in mounting pad.
10
Removing the Operator Housing
Before you can gain access to the operator frame and its mounting holes, the housing will have to be removed from the operator. Remove the (2) 3/8" chrome acorn nuts and (2) 3/8" washers from the operator housing (this hardware is located on the front of the housing). Lift the housing off the operator and set it aside.
Acorn nuts Washers
Mounting the Operator
1. Lift the operator and align its mounting holes over the 1/2" diameter concrete mounting anchors. Lower the operator into position and fasten it to the mounting anchors with (4) 1/2" washers and nuts (not provided). Step down on the foot pedal to disengage chain sprocket (see GTO FOOT PEDAL RELEASE on page 1). Bolt or weld (when correct position is determined) the chain brackets (included) on the operator side of the gate (see illustration on next page). Secure chain adjuster bolt using the (2) 1/2" nuts (included), one on each side of the bracket. Do not overtighten the nuts; they will be used to adjust chain tension. Use #40 chain with the GTO/PRO SL-5000, and #50 chain with the GTO/PRO SL-6000. Thread chain through chain sprockets (foot pedal release should already be activated). 2.
2.
3.
11
4.
Chain adjuster bolts: adjust outside nut until desired chain tension is achieved. Release foot pedal to re-engage chain sprocket.
5.
Chain Bracket
Sprocket
Chain Bracket
Roller Guides
!
WARNING
· Fingers, hands, and loose clothing may be dragged into chain sprockets. · Keep hands, fingers, and loose clothing away from chain and sprockets.
Chain
slack (1" for every 10' of chain)
Gate
Chain Bracket and Adjustment Bolt (included)
Chain (included)
Master Link (included)
Connecting Power to the Operator
Have a licensed electrician run 115 Vac wiring into a Field Wiring Connection Compartment (ON/OFF) box. The circuit must be protected with a 15 A main disconnect breaker (not provided). NOTE: Power and wiring connections MUST be installed by a licensed electrician in accordance with NEC (National Electric Code) and local codes. [. . . ] The warranty period for residential installations is five (5) years for mechanical parts; three (3) years for electronic components. The warranty period for commercial installations is three (3) years for mechanical parts; two (2) years for electronic components. In the case of product failure due to defective material or manufacturer workmanship within the warranty period, the operator will be repaired or replaced (at manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, Inc. , 3121 Hartsfield Road, Tallahassee, Florida 32303. IMPORTANT: Call (850) 575-0176 or Fax (850) 5758950 for a Return Goods Authorization (RGA) number before returning to factory. [. . . ]