User manual GRAUPNER ULTRAMAT 12

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRAUPNER ULTRAMAT 12. We hope that this GRAUPNER ULTRAMAT 12 user guide will be useful to you.


GRAUPNER ULTRAMAT 12 : Download the complete user guide (1440 Ko)

Manual abstract: user guide GRAUPNER ULTRAMAT 12

Detailed instructions for use are in the User's Guide.

[. . . ] KG, Henriettenstraße 94-96, 73230 Kirchheim/Teck, Germany guarantees this product for a period of 24 months from date of purchase. The guarantee applies only to such material or operational defects witch are present at the time of purchase of the product. Damage due to wear, overloading, incompetent handling or the use of incorrect accessories is not covered by the guarantee. The user´s legal rights and claims under garantee are not affected by this guarantee. [. . . ] 00 A, left of screen) until its voltage falls to the set final discharge voltage (05 . Deep-discharging a pack runs the risk of reversing individual cells, i. At top right you can use the INC or DEC button to determine whether the conditioning program is to start with a charge or discharge cycle. , if you set three cycles, the pack will be charged and discharged three times). The charge process is terminated automatically in accordance with the values already set for , , Ni-MH Delta Peak cut-off voltage". The fundamental rule is that Lithium-based batteries may ONLY be charged using voltage special chargers, and the charge program must be set up correctly in terms of final charge voltage and capacity for the battery type in use. For this reason it is essential to set the charger to the battery capacity instead of the charge current. When the battery on charge reaches the specific final voltage which is appropriate to the battery type, the charger automatically reduces the charge current in order to prevent the battery exceeding the final permissible voltage. If the battery manufacturer states a charge current lower than the 1C rate, then the capacity (charge current) must be reduced accordingly. 6491, which ensures that your Lithium batteries are charged optimally, and therefore increases their useful life. Problems caused by mistreating batteries: It is very dangerous to overcharge Lithium-Ion batteries, as they tend to react by gassing, overheating and even exploding. 2 V / cell (Lithium-Polymer and Lithium-Manganese) is exceeded by more than 1%, the lithium ions in the cell start to change into metallic lithium. This material reacts very violently with the water in the electrolyte, and this can result in the cell exploding. On the other hand it is also important to avoid terminating the charge process before the final charge voltage is reached, since this reduces the effective capacity of the Lithium-Ion cell markedly. Lithium batteries must not be deep-discharged, as this leads to a rapid loss of capacity. This effect is irreversible; it is absolutely vital to avoid discharging the batteries to below 2. Caution: the cell type, cell capacity and cell count set on the charger must always be correct for the battery to be charged; if you make a mistake, the battery could explode! never connect a Lithium-based battery to the charger if it features an integral charge circuit!Always place your Lithium batteries on a non-flammable surface for charging This program charges the battery using the capacity (charge current) which you set. C________ _: 2 5 0 0 m A h __ _____ Before you initiate the actual program you must set the capacity of the pack (and thus the maximum charge + current - range 50 . When you connect the pack to the charger and start the charge process, the charge current starts at 0. However, please do not be surprised if the charger does not reach the current you have set, because the charge program constantly monitors the battery voltage in order to prevent the pack inflating, provided that the voltage of the individual cells in the pack is the same. [. . . ] Do not allow batteries to come into contact with water - explosion hazard. It is best to , , balance", or even up the cells in Ni-Cd and Ni-MH battery packs by first discharging all the cells separately and then charging up the pack. Individual cells can be discharged using certain chargers, or they can be , , bridged" using a 100 Ohm resistor over each individual cell in the pack. Please don't be surprised if your batteries are not as willing to accept charge in winter as in summer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRAUPNER ULTRAMAT 12




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRAUPNER ULTRAMAT 12 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.