User manual GRAUPNER ULTRA DUO PLUS 60

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRAUPNER ULTRA DUO PLUS 60. We hope that this GRAUPNER ULTRA DUO PLUS 60 user guide will be useful to you.


GRAUPNER ULTRA DUO PLUS 60 : Download the complete user guide (2690 Ko)

You may also download the following manuals related to this product:

   GRAUPNER ULTRA DUO PLUS 60 GETTING STARTED (1166 ko)

Manual abstract: user guide GRAUPNER ULTRA DUO PLUS 60

Detailed instructions for use are in the User's Guide.

[. . . ] Modifications reserved. 1/55 PAGE PN. OF-01 Contents A-1 A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 0-1 0-2 0-3 1. Introduction Warnings and safety notes General notes on using the charger Recommended charge leads/polarity Charger controls /connections Using the charger for the first time Cleaning and maintenance Notes and handling of rechargeable batteries PC-Interface Features Main menu flow Control key select flow Memory and battery setup menu screen Charge setup menu flow Discharge setup screen Cycle menu screen Step charge menu screen Balancer Menü Data view screen Tyre, battery heater / battery heater screen / POWER SUPPLY Motor run-in screen Config setup screen Start select menu screen Battery select menu screen Operation menu screen Error message screen Specification Environnemental Protection Notes EU Conformity Declaration Warranty Page 3 4 5 7 8 8 9 9 12 14 15 16 17 19 22 24 25 27 29 32 34 36 38 45 46 52 53 54 54 55 2/55 PAGE A-1. INTRODUCTION Please study these instructions, reading them completely and attentively, before using the unit for the first time. This will guarantee that you will be able to exploit all the facilities of your new battery charger. [. . . ] - This mode should be activated when it moves to "REPEAK" mode from CHARGE PROCESS - Since this function is to charge again the fully charged battery, this PEAK DELAY should be automatically set to "0". ( PEAK DELAY setting value is not charged ) - Set wanted repeak charge cycle number. REPEAK DELAY - Set the delay time between first repeak and second repeak. Normally, LiPo battery is charged to 4. 2V/cell, for the battery storage, it can be charged to 3. 7V/cell with CV charging. - For charging range per battery type, please refer to "Setup Range sheet" and battery instruction. charging voltage settings are for: LiFe: 3. 6V/cell, LiIo: 4. 1V/cell, LiMn = LiPo: 4. 2V/cell. DISCHARGE MENU SCREEN --=------DISCHARGE SETUP<1/1> DCHG CURRENT _0. 0A DCHG CUTOFF _0. 0V/C CUT-TEMP. __0°C MAX CAPACITY __0% MATCHED VOLT _0. 00V 00°C DISCHARGE D:00. 0A 1. 0V/CL . . . 4x DISCHARGE SETUP<1/1> DCHG CURRENT _0. 0A DCHG CUTOFF _0. 0V/C CUT-TEMP. DISCHARGE MENU SCREEN Warning: Deep discharging cells and too high discharge currents can destroy the battery and can cause explosion and fire!If it is set to 1. 0V/Cell and its battery cell is 6cells, the discharge is finished at 6. 0V. For NiCd/NiMH batteries the cells should be never discharged lower as 1. 1V/cell. LiFe cells should be never discharged lower as 2. 5V/cell and LiPo/LiIo cells should be never discharge lower as 3. 0V/cell for the highest possible life time. Deep Discharge can cause capacity loss and in the worst case it can destroy the battery and cause explosion and fire. - Discharge is finished with smallest voltages with connecting the balancer cable the balancing port of the charger. Even if the cable is connected during discharging, discharge is not finished with cell voltage. CUT-TEMP - Connect the temp sensor to battery, and discharge is finished when it reaches the selected temp. Page 22/55 - This function is likely to be used more to prevent battery pack from being overheating rather than normal charge completion 3-4. MAX CAPACITY - This is to set your wanted discharge percentage against the selected battery capacity. - If "OFF" is set, this max capacity function is not activated. - If battery capacity is 3000mAh and if you set 10% out of the total max capacity, the charger should stop discharging at 300mAh 3-5. - This mode should be activated when it moves to "MATCH" mode from DISCHARGE PROCESS - To activate this mode, balancing cable MUST be connected to the balancing port of the charger. - Discharge to selected voltages with selected discharge currents and match each cell voltage. [. . . ] You can make an important contribution to the protection of our common environment by re-using the product, recycling the basic materials or recycling redundant equipment in other ways. Remove batteries from your device and dispose of them at your local collection point for batteries. In case of R/C models, you have to remove electronic parts like servos, receiver, or speed controller from the product in question, and these parts must be disposed of with a corresponding collection point for electrical scrap. If you don't know the location of your nearest disposal centre, please enquire at your local council office. EU Conformity Declaration We hereby declare that the following product: ULTRA DUO PLUS 60; Order-No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRAUPNER ULTRA DUO PLUS 60




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRAUPNER ULTRA DUO PLUS 60 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.