User manual GRASS VALLEY CONCERTO 1.7.6.1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRASS VALLEY CONCERTO 1.7.6.1. We hope that this GRASS VALLEY CONCERTO 1.7.6.1 user guide will be useful to you.


GRASS VALLEY CONCERTO 1.7.6.1 : Download the complete user guide (5481 Ko)

Manual abstract: user guide GRASS VALLEY CONCERTO 1.7.6.1

Detailed instructions for use are in the User's Guide.

[. . . ] Concerto ROUTING MATRIX Instruction Manual Software Version 1. 7. 6. 1 071813811 OCTOBER 2009 Affiliate with the N. V. KEMA in The Netherlands CERTIFICATE Certificate Number: 510040. 001 The Quality System of: Thomson Inc, and it's wordwide Grass Valley division affiliates DBA GRASS VALLEY Headquarters 400 Providence Mine Rd Nevada City, CA 95959 United States Kapittelweg 10 4827 HG Breda The Nederlands Rue du Clos Courtel CS 31719 35517 Cesson-Sevigné Cedex France 40 Rue de Bray 2 Rue des Landelles 35510 Cesson Sevigné France Carl-Benz-Strasse 6-8 67105 Schifferstadt Germany 15655 SW Greystone Ct. Beaverton, OR 97006 United States 7140 Baymeadows Way Ste 101 Jacksonville, FL 32256 United States 1 rue de l'Hautil Z. I. des Boutries BP 150 78702 Conflans-Sainte Honorine Cedex France Spinnereistrasse 5 CH-5300 Turgi Switzerland 10 Presidential Way Suite 300 Woburn, MA 01801 United States 2300 So. [. . . ] A 15 pin D to 15 pin D cable. See Figure 48 for cabling of a single non-redundant Crosspoint Bus Controller matrix. Figure 48. Non-redundant Connection between Concerto and Jupiter Concerto MON IN MON OUT EXP IN 1 2 AUDIO/DATA TDM EXP OUT 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 18 14 10 6 2 28 24 20 16 12 8 1 2 32 30 28 24 20 16 12 8 4 30 26 22 18 14 10 6 4 2 MON IN MON OUT EXP IN INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 AUDIO/DATA TDM 18 14 10 6 2 28 24 20 16 12 8 1 2 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 1 2 EXP OUT 32 30 28 24 20 16 12 8 4 30 26 22 18 14 10 6 4 2 To Jupiter Control System G A 29 B A 25 B A 29 B A 25 B A 29 B A 25 B A 21 B A 17 B A 13 B A 9B A B MON. OUT 1 2 A 30 B A 26 B A 30 B A 26 B A 22 B A 18 B A 14 B A 10 B A B + G+ EXP. IN INPUTS A 31 B A 27 B A 23 B A 21 B A 19 B A 17 B A 15 B A 13 B A 11 B A 9B A 7B A 3B A 31 B A 27 B A 23 B A 19 B A 15 B A 11 B A 7B A 5B OUTPUTS A 3B A 1B A 32 B A 28 B A 24 B A 22 B A 20 B A 18 B A 16 B A 14 B A 12 B A 10 BA 8BA 4 B A 32 B A 28 B A 24 B A 20 B A 16 B A 12 B A 8B A 6B A 3B A B 1 29 10 17 18 EXP. OUT 1 2 23 24 AES BALANCED BACKPLANE 21 22 3 4 11 12 19 20 INPUTS EXP. IN OUTPUTS 1 2 + G+ G MONITOR 5 6 13 14 21 22 25 26 29 30 31 32 3 47 8 11 12 15 16 19 20 27 28 31 32 IN OUT XPT BUS 7 8 15 16 23 24 27 28 1 25 69 10 13 14 17 18 25 26 29 30 IN OUT 36-60V 400W; 11. 1A - + EXT COM 2 EXT COM 1 E-NET 2 E-NET 1 EXT COM AES REF ALARM VID-REF 2 VID-REF 1 Terminator Thomson 9 pin D to 15 pin D Adaptor AC PWR 1 100-240V 50/60Hz AC PWR 2 500W; 5A 8138_03_95r1 90 Concerto -- Instruction Manual Cabling A second Crosspoint Bus Controller module ordered to provide redundancy will include the following: · · A 9 pin D to 9 pin D cable (for pinouts see Table 35 on page 85), A 9 pin D to 15 pin D adaptor box, and The adaptor box comes with a bracket that can be mounted in any of three positions on the box and is mounted on a rack support at the rear of the Concerto Matrix. Note XPT BUS EXT COM 8138_03_96r1 · A 15 pin D to 15 pin D cable. See Figure 49 for cabling of a redundant Crosspoint Bus Controller matrix. Figure 49. Redundant Connection between Concerto and Jupiter Control Frame Concerto MON IN MON OUT EXP IN 1 2 AUDIO/DATA TDM EXP OUT 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 18 14 10 6 2 28 24 20 16 12 8 1 2 32 30 28 24 20 16 12 8 4 30 26 22 18 14 10 6 4 2 MON IN MON OUT EXP IN INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 AUDIO/DATA TDM 18 14 10 6 2 28 24 20 16 12 8 1 2 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 1 2 EXP OUT 32 30 28 24 20 16 12 8 4 30 26 22 18 14 10 6 4 2 To Jupiter Control System G A 29 B A 25 B A 29 B A 25 B A 29 B A 25 B A 21 B A 17 B A 13 B A 9B A B MON. OUT 1 2 A 30 B A 26 B A 30 B A 26 B A 22 B A 18 B A 14 B A 10 B A B + G+ EXP. IN INPUTS A 31 B A 27 B A 23 B A 21 B A 19 B A 17 B A 15 B A 13 B A 11 B A 9B A 7B A 3B A 31 B A 27 B A 23 B A 19 B A 15 B A 11 B A 7B A 5B OUTPUTS A 3B A 1B A 32 B A 28 B A 24 B A 22 B A 20 B A 18 B A 16 B A 14 B A 12 B A 10 B A 8B A 4B A 32 B A 28 B A 24 B A 20 B A 16 B A 12 B A8B A6B A3B A2B Terminator 1 29 10 17 18 EXP. OUT 1 2 23 24 AES BALANCED BACKPLANE 21 22 3 4 11 12 19 20 INPUTS OUTPUTS EXP. IN 1 2 + G+ G MONITOR 5 6 13 14 21 22 25 26 29 30 31 32 3 47 8 11 12 15 16 19 20 27 28 31 32 IN OUT XPT BUS XPT BUS 7 8 15 16 23 24 27 28 1 25 69 10 13 14 17 18 25 26 29 30 IN OUT 36-60V 400W; 11. 1A - + EXT COM 2 EXT COM 1 E-NET 2 E-NET 1 EXT COM AES REF ALARM VID-REF 2 VID-REF 1 0. 3 m (1 ft) Thomson 9 pin D to 15 pin D Adaptors EXT COM AC PWR 1 100-240V 50/60Hz AC PWR 2 500W; 5A 8138_03_96r1 Concerto -- Instruction Manual 91 Section 2 -- Installation Ethernet Communications Ethernet is used for communication between the Concerto and either an Encore or SMS 7000 Control System frame. Communications can be established using either E-NET 1 (to communicate with the Controller in slot 1) or E-NET 2 (to communicator with the Controller in slot 2). One connection can be used as a primary connection and the other can be used as a redundant connection. Network Connection between Concerto and Control Frame Concerto MON IN MON OUT EXP IN 1 2 AUDIO/DATA TDM EXP OUT 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 18 14 10 6 2 28 24 20 16 12 8 To Control Frame 6 4 2 1 2 32 30 28 24 20 16 12 8 4 30 26 22 18 14 10 MON IN MON OUT EXP IN INPUTS 25 21 17 13 9 5 1 31 27 23 19 15 11 7 OUTPUTS 22 AUDIO/DATA TDM 18 14 10 6 2 28 24 20 16 12 8 1 2 31 29 27 26 23 19 15 11 7 3 32 29 25 21 17 13 9 5 3 1 1 2 EXP OUT 32 30 28 24 20 16 12 8 4 30 26 22 18 14 10 6 4 2 A 29 B A 25 B A 29 B A 25 B A 29 B A 25 B A 21 B A 17 B A 13 B A 9B A B MON. OUT 1 2 A 30 B A 26 B A 30 B A 26 B A 22 B A 18 B A 14 B A 10 B A B + G+ G EXP. IN INPUTS A 31 B A 27 B A 23 B A 21 B A 19 B A 17 B A 15 B A 13 B A 11 B A 9B A 7B A 3B A 31 B A 27 B A 23 B A 19 B A 15 B A 11 B A 7B A 5B OUTPUTS A 3B A 1B A 32 B A 28 B A 24 B A 22 B A 20 B A 18 B A 16 B A 14 B A 12 B A 10 B A 8B A 4B A 32 B A 28 B A 24 B A 20 B A 16 B A 12 B A8B A6B A3B A2B 1 29 10 17 18 EXP. OUT 1 2 23 24 AES BALANCED BACKPLANE 21 22 3 4 11 12 19 20 INPUTS OUTPUTS EXP. IN 1 2 + G+ G MONITOR Managed Ethernet Switch 5 6 13 14 21 22 25 26 29 30 31 32 3 47 8 11 12 15 16 19 20 27 28 31 32 IN OUT 7 8 15 16 23 24 27 28 1 25 69 10 13 14 17 18 25 26 29 30 IN OUT 36-60V 400W; 11. 1A - + EXT COM 2 EXT COM 1 E-NET 2 E-NET 1 AES REF ALARM VID-REF 2 VID-REF 1 AC PWR 1 100-240V 50/60Hz AC PWR 2 500W; 5A 8138_00_18r1 References Concerto requires a Video Reference. Most composite analog video sync signals will work with the exception of 4 Volt and 2 Volt discreet sync signals. To allow time stamped deterministic switching, the Video Reference must contain an embedded Vertical Interval Time Code (VITC) signal. The AES sync reference loop-thru input provides a 48 kHz formatted signal for re-synchronization to frame and block boundaries. The signal is required for the Analog Audio and the Digital Audio (AES) modules to function properly. [. . . ] Commonly used in telecommunications to connect computers and terminals to modems and other devices. The C suffix refers to the version of the RS-232 standard. Remote Remote is used during configuration to identify remote Sources and Destinations. Remote Sources and Destinations are inputs and outputs not physically connected to the System using the related configuration file. These remote Sources and Destinations are controlled over a network. RS-485 A high-speed serial interface connection between data communications equipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRASS VALLEY CONCERTO 1.7.6.1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRASS VALLEY CONCERTO 1.7.6.1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.