Manual abstract: user guide GEORG FISCHER EA30

Detailed instructions for use are in the User's Guide.

[. . . ] Introduction This instruction manual contains all the information regarding design, installation and start-up procedure for the electrical actuator unit type EA 30. Warnings: ¼ Do not work on this unit before disconnecting it from the mains!¼ The actuator is factory preset to a mains voltage of 230 V AC. [. . . ] Limit switch positions Switch S1 opens at <open> position Switch S2 opens at <closed> position (see diagram in the margin) Procedure Both switching cams S1 and S2 are to be adjusted so that the actuating angle is less than 90°). Drive the actuator until one limit switch, either <closed> or <open> is operated. The end positions can be adjusted by moving the switching cams, as the actuator follows them. ¼ For George Fischer ball valves an exact 90°) rotation should be set. ¼ For George Fischer butterfly valves the <closed> position should be adjusted according to the following directions. S2 S1 GEORGE FISCHER . . . 49 G/2 a Setting the <closed> position in actuators At the <closed> position in butterfly valves the disk is not exactly vertical to the pipe axis. Deviation values can be taken from the following table. open a­b b DN mm 65 80 d mm 75 90 a­b mm 4 4 50 GEORGE FISCHER . . . 5. 5 / 230 V, 50­60 Hz (switchable) 24 V = / 24 V, 50­60 Hz 48 V, 50­60 Hz on request @2 W IP 65 in accordance with DIN 40050 @00% at 25 °C / 70% at 50 °C, 20 min Dependent on current and time (automatic reset) 1) Cable plug 3 P+E in accordance with DIN 43650 additional cable connections PG 270°, set to 90° 25 Nm 50 Nm ­@0° to +50 °C 2) 0­98%, non-condensing PP fiberglass reinforced external screws rust-proof visual, integrated Power consumption Protection Duty cycle Overload protection Electric connection Control time Angle of operation Continuous torque Peak torque Operating temperature Permissible humidity Body material Position indicator 1) The overload protection is designed to protect both motor and power supply board. If the overload protection device has triggered, it will reset automatically when the unit has cooled down sufficiently and the actuator will operate again. @43 should be installed (see Item 6. 5). 2) GEORGE FISCHER . . . 51 5. 2 Block Diagram input voltage selection 230 V 1@5 V Closed 2 N S2 power supply overload protection Open L 1 S1 M N 230 V 1@5 V reversing circuit 5. 3 Dimensions 72 56. 4 159 63. 7 185 120. 7 61 146 85 15 52 GEORGE FISCHER . . . 6. Assembly and Connection of Modular Components The electrical actuator EA 30 is equipped with fastening points which allow for additional modular components to be mounted. The electrical connection is made by means of a second cable plug or a threaded cable joint (depending on the number of connecting wires). The respective kits are prepared for installation, the electric cables are cut to size and package accordingly. In the following sections, the corresponding assembly points and the wiring are illustrated. GEORGE FISCHER . . . 53 6. 1 Mechanical limit switches Description Kit with 2 additional auxiliary switches Kit with 4 additional auxiliary switches Kit with 2 additional auxiliary switches with gold contacts 1 2 1 Additional switching cams 2 Limit switch S5, S6 or S5 to S8 Technical Data 250 V , @0 A 250 V , @0 A 4­30 V = 1­@00 mA Code @99 @90 @38 @99 @90 @39 @99 @90 @49 Wiring diagram Nr. . 149 M S1 S2 S6 14 2 S5 14 2 M S1 S2 14 2 14 2 14 2 14 2 black white black red FED 654N21 65 FED 4N2 1 1 3 2 1 B A DC AC L1 N PE B A DC AC L1 N PE 54 GEORGE FISCHER . . . 6. 2 Inductive limit switches The mechanical installation of these switches is identical to those under 6. 1. An additional metal part must be mounted so that the active surface of the inductive switch can be activated. Description Kit with 2 additional auxiliary switches inductive, with LED NPN Kit with 2 additional auxiliary switches inductive, with LED PNP Kit with 2 additional auxiliary switches inductive Namur Technical Data 9, 6­55 V = 0, 2 A 9, 6­55 V = 0, 2 A 5­24 V = @0 mA Code @99 @90 @46 @99 @90 @47 @99 @90 @48 Wiring Diagram Nr. @99 @90 @47 PNP S6 ­+A S5 ­+A M S1 S2 +­ Wiring Diagram Nr. [. . . ] +46(0)8/727 47 00, Fax +46(0)8/749 23 70 e-mail: info@georgfischer. se, Internet: http://www. georgfischer. se George Fischer Pte. Ltd. , ¢5 Kaki Bukit Road 2, KB Warehouse Complex, 4¢7 845 Singapore/Singapore Tel. +65(0)7/47 06 ¢¢, Fax +65(0)7/47 05 77, e-mail: info@georgfischer. com. sg George Fischer Inc. , 2882 Dow Avenue, Tustin, CA 92780-7285 Tel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GEORG FISCHER EA30




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GEORG FISCHER EA30 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.