User manual GE INTERLOGIX SIMON 3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GE INTERLOGIX SIMON 3. We hope that this GE INTERLOGIX SIMON 3 user guide will be useful to you.


GE INTERLOGIX SIMON 3 : Download the complete user guide (666 Ko)

Manual abstract: user guide GE INTERLOGIX SIMON 3

Detailed instructions for use are in the User's Guide.

[. . . ] ) ZZZ*(, QWHUORJL[6HFXULW\FRP 466-1873 Rev F September 2002 *( , QWHUORJL[ Part No: 60-875 60-910 (Not investigated for use by UL) Doors & Motion Windows Sensors System Status HOME SECURITY Arm 1/2 3/4 Disarm 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor On Off HOME CONTROL Bypass Lights EMERGENCY FIRE POLICE AUX Test Weekly Simon Security System Installation Instructions FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by Interlogix Inc. FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ] To set Exit Delay, press: Add--Option #--11--3-digit delay time--DONE. To reset Exit Delay (return to default), press: Delete--Option #--11--DONE. Note For UL listed systems, the exit delay must not exceed 60 seconds. Option 12: Phone Mod 1 (Default = 0) Note UL has only verified reporting compatibility with the CS5000 Digital Alarm Communicator Receiver. For UL listed systems, Phone Mod 1 must be set to 0 or 1. Determines the primary phone number (Option 4) report content and reporting format. Phone Mod 1 Setting # 0 1 2 3 All All Alarms only Alarms only Content Format SIA Contact ID SIA Contact ID Alarms include: Fire, Intrusion, Emergency, Silent, and Alarm Cancels. Non-alarms include: Latchkey, No Activity, Openings, Closings, Fail to Open, Fail to Close, Force Armed, AC Power Failure, CPU Low Battery, and Trouble Restorals. To reset Phone Mod 1 (return to default), press: Delete--Option #--12--DONE. Option 13: Phone Mod 2 (Default = 00) Determines the secondary phone number (Option 5) report content and reporting format. Phone Mod 2 Setting # 00 01 02 All All Alarms only Content SIA Contact ID SIA Format 23 Simon Security System Phone Mod 2 Setting # 03 04 05 06 07 08 09 10 Alarms only Non-Alarms only Non-Alarms only Phone 1 failure Phone 1 failure Content SIA Contact ID SIA Contact ID Format Contact ID Latchkey, No Activity, Phone Test, Openings, Closings, Pager Fail to Open/Close, AC Power Restorals/Failures Same as setting 8 plus Alarms Pager Alarms and Latchkey only (See Options 43 and 44 for Voice Event more details. ) Notification To set Phone Mod 2, press: Add--Option #--13--0, 1, 2, or 3--DONE. To reset Phone Mod 2 (return to default), press: Delete--Option #--13--DONE. Option 14: DTMF Dialing (Default = on) Determines whether the panel uses DTMF (on) or pulse (off) for dialing programmed phone numbers. To turn off DTMF Dialing, press: Delete--Option #--14--DONE. Option 15: No Activity Time-out (Default = off) Determines whether the panel sends a No Activity report to a central station or pager when the programmed time period elapses (on), or if the feature is disabled (off). No activity means control panel, remote handheld, and keychain touchpad buttons have not be pressed and sensors have not been tripped within a specified period of time (except sensors in group 25). To set No Activity Time-out, press: Add--Option #--15--02 - 24--DONE. To turn off No Activity Time-out, press: Delete--Option #--15--DONE. Option 16: Auto Phone Test (Default = off) Determines whether the panel automatically performs a periodic phone test (on) or not (off). The time of day the panel performs the test is determined by Option 72: Supervisory Time, which must be turned on for this feature to work. To turn off Auto Phone Test, press: Note For UL 1635 listed systems, Auto Phone Test must be set to 001 days. Simon Security System 24 Delete--Option #--16--DONE. Option 17: Dialer Delay (Default = off) Determines whether the panel delays dialing programmed phone numbers before sending reports (on), or if dialing begins immediately (off). If Option 21: Opening (Disarming) Reports is on, the panel does not delay dialing if the system is disarmed before the delay time expires. The panel dials immediately for both the alarm and opening report. Note Regardless of this option setting, the panel always dials immediately for alarms from sensors in groups 0-8, 26, for alarms triggered by the control panel or remote handheld touchpad emergency buttons, and for programming, AC power failure, and low battery reports. Note For UL installations, the Dialer Delay must not exceed 45 seconds. The delay time can be set from 005 - 254 seconds (015 to 045 if Option 69: SIA Limits is on). To turn off Dialer Delay, press: Delete--Option #--17--DONE. Option 18: Alarm Cancel Report (Default = 005 minutes) Sets the time frame that determines whether the panel reports an alarm cancel message to the central station. If the system is disarmed from an alarm state within the programmed time, the panel sends an alarm cancel message to the central station. An alarm cancel message is not reported if the system is disarmed after the programmed time expires. To turn on Alarm Cancel Report, press: Add--Option #--18--005 - 255--DONE. To turn off Alarm Cancel Report, press: Delete--Option #--18--DONE. Option 19: RF Timeout (Default = 12 hours) Determines the time period the panel must receive at least one supervisory signal from learned sensors before identifying a sensor failure and sounding trouble beeps. Any sensor failure is reported immediately and again at the supervisory time (Option 72: Supervisory Time). Note Setting this feature to 2 hours (02) may cause false reports. [. . . ] Chime 14 Instant Interior: Interior doors 15 Instant Interior: Interior PIR motion sensors* 16 Instant Interior: Interior doors 17 Instant Interior: PIR motion sensors and Sound sensors* 18 Instant Interior Cross Zone: PIR motion sensors* 19 Delayed Interior: interior doors that initiate a delay before going into alarm* 20 Delayed Interior: PIR motion sensors that initiate a delay before going into alarm* 21 Local Instant Interior: 24 hour local alarm zone protecting anything that opens and closes. No Report 22 Local delayed interior: same as group 21, plus activation initiates a delay before going into alarm. No report. * 23 Local instant Auxiliary: 24 hour local alarm zone protecting anything that opens and closes. No report 24 Local Instant Auxiliary: 24 hour local alarm zone protecting anything that opens and closes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GE INTERLOGIX SIMON 3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GE INTERLOGIX SIMON 3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.