If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GARDINER TECHNOLOGY GARDTEC 800. We hope that this GARDINER TECHNOLOGY GARDTEC 800 user guide will be useful to you.
Manual abstract: user guide GARDINER TECHNOLOGY GARDTEC 800
Detailed instructions for use are in the User's Guide.
[. . . ] GARDINER TECHNOLOGY
GARDTEC 800 Series
LCD User Instructions & LED User Instructions
GARDTEC 800 Series
User Manual
Contents
User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using LCD Keypads Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Code Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting The System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] STUART ?
3)
Press NO five times, the display will show:-
Do you want to . USER CODES ?
4)
Press YES, the display will show:(1 - 7) displayed on 800 & 816
Enter User No. (1- 47) Then YES
--
5)
Enter the user number (1 to 47 for 840 or 1 to 7 for 800/816) that you wish to program followed by YES, the display will show:-
Now Enter Code . - - - - - - Then YES
Page 14
GARDTEC 800 Series
6) Enter the code you require (codes may be 4, 5 or 6 digits) followed by YES. (Entering 000000 will delete an existing code) If the code already exists or is a duress of another code an error will be shown, choose another code and return to step 6 The display will show:(not if user 1 is being programmed). The display will scroll showing the code types available (see user types or display).
User Manual
Note:
7)
Choose Type . 0 = xxxxxx 1 = xxxxxx
8)
Enter the required type followed by YES, the display will show for example:(816 & 840 Only)
User 1 Name = STUART
9)
If you wish to accept the name shown press YES and jump to step 13 Or If you wish to change the name shown press NO, the display will show:User 1 Name >
10)
You may now enter up to nine characters for the user name using the layout shown below for the allocation of characters.
1
ABC
2
DEF
3
GHI
4
JKL
5
MNO
6
PQR
7
STU
8
VWX
9
YZ
NO
0
0-9
YES
Page 15
User Manual
11)
GARDTEC 800 Series
Referring to the character map enter the required character (pressing the 3 key will display 'G', pressing it again will show 'H' and again will show 'I '), once the correct character is displayed press YES and the display will move on to the next position.
12)
Continue entering characters (up to 9). If you require a blank space press YES while the '-' is displayed As you press YES for the ninth character (or if you have jumped from step 9) the display will change to:Do you want to . USER CODES ?
13)
14)
If you wish to program other User Codes return to step 4 Or Press 0 to return to:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
Page 16
GARDTEC 800 Series
User Manual
Programming Time & Date
1) With the display showing:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
2)
Enter a Master Code, the display will show:(User Names on 816 & 840 Only)
Do you want to . STUART ?
3)
Press NO six times, the display will show:-
Do you want to . Set DATE / TIME ?
4)
Press YES the display will show:-
Enter Day / Month -- -- / -- -- Then YES
5)
Enter the Day/Month (ie. The display will show:-
Enter Hrs / Mins -- -- : -- -- Then YES
6)
Enter the time using 24Hr Clock (ie. 23:30 for 11:30pm) followed by YES the display will show:-
Do you want to . Set DATE / TIME ?
7)
Press 0 the display will show:-
< < < < UN-SET > > > > 07 Jun 23: 30: 02
Page 17
User Manual
GARDTEC 800 Series
User Initiating Remote Access (Optional)
Access Remote allows your installation company to examine your system and reprogram system settings as you need the changes without the need for an engineer to visit your premises. If your system has remote communications fitted your installation company may have programmed the system so that you initialise the Access Remote call (usually on lines with incoming calls barred). 1) Negotiate with your installation company when you should initiate the Remote Call. With the display showing:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
2)
3)
Enter a Master Code, the display will show:(User Names on 816 & 840 Only)
Do you want to . STUART ?
4)
Press NO seven times, the display will show:-
Do you want to . Access Remote ?
5)
Press YES the display will show:Until Dialling commences Then:-
Please WAIT
Please WAIT Dialling
Until Connection Then:Please WAIT Connect
6)
When your installation company has finished the display will show:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
Note:
In the event of any errors the display will show:-
!.
Page 18
GARDTEC 800 Series
User Manual
Resetting After an Alarm
Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements. Your installation company will have informed you as to the type of reset that your system is set for. Before attempting to reset your system ensure that the system is Un-set.
1)
If the system is programmed for any code reset enter a user (followed by YES if Master or Main code is used), the exit tone will sound and the display will show for example:(1 2 3 may not show on Gardtec 800 & 816)
EXIT Now ! [. . . ] (flashing) Call Engineer
'Fb' 'Cb' 'bb' 'E1'
'PL'
'Pc' 't4'
Page 29
User Manual
Displays Whilst Viewing Log '04' Alarm occurred because of zone 4 was activated. read Log.
GARDTEC 800 Series
'04'
'04' 'Lr ' 'Pr ' 'd3 ' 'rE ' 'Ar ' 'bo ' '01'
'F2'
'A2'
'P2'
't F' 'rL'
Page 30
GARDTEC 800 Series
User Manual
System Attributes
Zone No. Example 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 Zone Type E/E Descriptor(816/840) Front Door Areas(840) 1&2 Part Info A1 Pt2
Page 31
User Manual
Zone No. 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 Zone Type Descriptor(816/840)
GARDTEC 800 Series
Areas(840) Part Info
Page 32
GARDTEC 800 Series
Zone No. [. . . ]