If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAI-TRONICS 12578-003. We hope that this GAI-TRONICS 12578-003 user guide will be useful to you.


GAI-TRONICS 12578-003 : Download the complete user guide (240 Ko)

Manual abstract: user guide GAI-TRONICS 12578-003

Detailed instructions for use are in the User's Guide.

[. . . ] This module address is set by rotary hex switches S1 and S2 of the MIM (located on the CPU PCBA. ) The range of valid settings is from 05 to FE (hex). GAI-Tronics Corporation 400 E. Mohnton, PA 19540 USA 610-777-1374 800-492-1212 Fax: 610-796-5954 VISIT WWW. GAI-TRONICS. COM FOR PRODUCT LITERATURE AND MANUALS Model 12578-003 Monitored Input Module (MIM) Pub. 42004-715L2B Page 2 of 12 Each input may be independently configured to operate in one of the following five modes: Input Mode Description Comments 0 1 2 3 4 5 5 Deactivate circuit IDC line supervision multiple switch IDC single N. O. Detects open circuit, ground faults, and switch actuation from one or more normally-open dry contact closures. [. . . ] IDC Line Supervision Multiple Switch NOTE: The 20 k, 5% tolerance resistor is not included with the MIM. This resistor is included in a kit (12509-003), which must be ordered separately. f:\standard ioms - current release\42004 instr. manuals\42004-715l2b. doc 11/11 Model 12578-003 Monitored Input Module (MIM) Pub. 42004-715L2B Page 6 of 12 Model 2: IDC Single Normally-Open (N. O. ) Switch In this configuration, only one normally-open dry contact closure may be installed per supervised line. In this mode, the loop is monitored for open circuits, wire-to-wire short circuits (across + and -), and ground faults. When the contact closure is not active (open), the loop appears as 20. 1 k load (15 k in series with 5. 1 k). When the contact closure is active (closed), the 15 k resistor is bypassed. Figure 3. IDC Single Normally-Open Switch The circuit then sees only the 5. 1 k load. This changes the value of the input and indicates to the MIM that the contact closure is active. If there is a short across + and -, if either leg is grounded, or if a break occurs on either leg, the MIM indicates that a fault has occurred. These resistors are included in a kit (12509-003) that must be ordered separately. f:\standard ioms - current release\42004 instr. manuals\42004-715l2b. doc 11/11 Model 12578-003 Monitored Input Module (MIM) Pub. 42004-715L2B Page 7 of 12 Mode 3: IDC Single Normally-Closed (N. C. ) Switch In this configuration, only one normally-closed dry contact closure may be installed per supervised line. In this mode, the loop is monitored for open circuits, wire-to-wire short circuits (across + and -), and ground faults. When the contact closure is not active (closed), the 15 k is bypassed and the circuit sees only the 5. 1 k load. Figure 4. IDC Single Normally-Closed Switch When the contact closure is active (open), the loop appears as a 20. 1 k load (15 k in series with 5. 1 k). This changes the value of the input and indicates to the MIM that the contact closure is active. If there is a short across + and -, if either leg is grounded, or if a break occurs on either leg, the MIM indicates that a fault has occurred. These resistors are included in a kit (12509-003) that must be ordered separately. Mode 4: IAC Line Supervision (Reserved for 12579-003 Monitored Relay Module) f:\standard ioms - current release\42004 instr. manuals\42004-715l2b. doc 11/11 Model 12578-003 Monitored Input Module (MIM) Pub. 42004-715L2B Page 8 of 12 Mode 5: IDC Non-Supervision Multiple Switch (Dry Contact) In this mode, any number of normally-open dry contact closures can be installed on the line. [. . . ] The applicability of any such third-party warranty will be determined by GAI-Tronics. Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors, shall be performed in accordance with the standard of care with which such services are normally provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided any and all issues are identified prior to the demobilization of the Contractor's personnel from the work site. Re-performance of services shall be Buyer's sole and exclusive remedy, and in no event shall GAITronics warranty obligations with respect to services exceed 100% of the total cost of the services provided hereunder. Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty periods as set forth above. Provided, however, that if the defect complained of is latent and not discoverable within the above warranty periods, every claim arising on account of such latent defect shall be deemed waived unless it is made in writing within a reasonable time after such latent defect is or should have been discovered by Buyer. Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent caused by Buyer's neglect, failure to follow operational and maintenance procedures provided with the equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the equipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAI-TRONICS 12578-003




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAI-TRONICS 12578-003 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.