User manual FURUNO SC-110 OPERATORS MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO SC-110. We hope that this FURUNO SC-110 user guide will be useful to you.


FURUNO SC-110 OPERATORS MANUAL: Download the complete user guide (2001 Ko)

Manual abstract: user guide FURUNO SC-110OPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] THD SATELLITE COMPASS SC-110 Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : fax : 0798-65-2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION : FEB . OME-72570 ( DAMI ) SC-110 *00014854600* *00014854600* *00014854600* *OME72570A20* *OME72570A20* *OME72570A20* SAFETY INSTRUCTIONS Safety Instructions for the Operator Safety Instructions for the Installer WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire. Do not place liquid-filled containers on the top of the processor unit. [. . . ] To restore a satellite, enter "00". 2. 8 2. 8. 1 Output Data Heading Heading data is output from the DATA OUT port on the processor unit, in IEC 61162-1/2 format. Choose I/O SETUP and then press the [ENT] key. OUTPUT DATA SETUP DATA OUT1: AD-10 DATA OUT2: AD-10 DATA OUT3: IEC DATA OUT4: IEC DATA OUT5: IEC LOG PULSE: 200 P/NM OUTPUT DATA SETUP menu 3. Choose DATA OUT1 and then press the [ENT] key. AD-10 IEC Data out options 4. Use the Omnipad to choose AD-10 or IEC as appropriate and then press the [ENT] key. If you choose AD-10, no further operation is required; go to step 18 to finish. For IEC go to the next step. DATA OUT1 SENTENCE: HDG VTG ROT HDT HDM GLL ZDA VHW VBW BAUD RATE: 4800BPS INTERVAL: 100mS NMEA VER: IEC ED2 HDG TALKER: GP DATA OUT1 menu 2-9 2. Choose SENTENCE and then press the [ENT] key. DATA OUT1 HDT HDM ROT ATT VDR VTG GGA GNS GLL VHW VBW HVE ZDA DATA OUT1 menu, sentences 6. HDT: True heading (required for radar, AIS, ECDIS, etc. ) HDM: Magnetic heading (HDM is obtained in this equipment by adding the magnetic variation to HDT. ) ROT: Rate-of-turn data ATT: True heading, pitching, rolling (FURUNO's proprietary sentence) VDR: Set and drift VTG: Course over ground and ground speed GGA: Global positioning system (GPS) fix data GNS: GNSS fix data GLL: Geographic position, latitude/longitude VHW: Water speed and heading VBW: Dual ground/water speed HVE: GPS antenna up-down motion amplitude (FURUNO proprietary sentence) ZDA: Time and date OFF ON 7. Use the Omnipad to choose OFF or ON as appropriate and then press the [ENT] key. The message "SENTENCE OVERLOAD" appears when too many sentences have been selected. Choose BAUD RATE and then press the [ENT] key. 4800BPS 9600BPS 19200BPS 38400BPS Baud rate options 2-10 2. Use the Omnipad to choose the baud rate of the equipment connected and then press the [ENT] key. INTERVAL is selected; press the [ENT] key. 25ms 100ms 200ms 1S 2S Tx interval options 13. Use the Omnipad to choose appropriate output interval and then press the [ENT] key. Choose IEC VERSION and then press the [ENT] key. IEC ED1 IEC ED2 NMEA 1. 5 IEC, NMEA version options 15. Choose appropriate IEC (or NMEA) edition and then press the [ENT] key. Choose HDG TALKER and then press the [ENT] key. GP HE HN HC Heading talker options 17. GP: GPS navigator talker HE: North-seeking gyrocompass talker HN: Non-north seeking gyrocompass talker HC: Magnetic compass talker 18. Press the [DISP] key to close the menu, or press the [MENU] key to return to the I/O SETUP menu to setup another output port. 2-11 2. OPERATION Output sentence limitation The number of sentences which can be output depends on baud rate and output interval settings. The maximum number of characters per each data sentences are shown in the table below and the total number of characters must satisfy the formula shown below. The number of characters which can be output "N" is calculated by the following formula N < 0. 083 x T x B T: Interval (s) B: Baud rate Sentence and maximum number of characters Sentence No. [. . . ] In principle, a pair of two antennas A1(ref) and A2(fore), each connected with an associated GPS engine and processor, are installed along the ship's fore-and-aft line. GPS systems at A1 and A2 calculate the range and azimuth to the satellite. "n" is automatically found during the initialization stage by receiving three satellites. A fraction of a carrier wavelength, , is processed by FURUNO's advanced kinematic technology in geographical survey, thus determining a vector (range and orientation) A1 to A2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO SC-110




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO SC-110 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.