[. . . ] COLOR VIDEO PLOTTER GD-1700C COLOR VIDEO PLOTTER GD-1710C VIDEO PLOTTER GD-1700
Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : fax : 0798-65-2111 0798-65-4200
All rights reserved.
Printed in Japan
FIRST EDITION : APR. OME-44090 ( HIMA ) GD-1700/1700C/1710C
*00080918401* *00080918401*
*00080918401*
*OME44090G00* *OME44090G00*
*OME44090G00*
SAFETY INSTRUCTIONS
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment. Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire. A heater can melt the equipment's power cord, which can cause fire or electrical shock. [. . . ] To distinguish real target echoes from sea clutter, echo average performs scan-to-scan correlation. Correlation is made by storing and averaging echo signals over successive picture frames. If an echo is solid and stable, it is presented in its normal intensity. Sea clutter is averaged over successive scans resulting in the reduced brilliance, making it easier to discriminate real targets from sea clutter. To properly use the echo average function, it is recommended to first suppress sea clutter with the A/C SEA control and then do the following: 1. If not displayed, press the [HIDE/SHOW] key to display the radar soft keys. OFF: LOW: No averaging Helps distinguish targets from sea clutter and suppresses brilliance of unstable echoes. The display shows EAV L, EAV M or EAV H when echo averaging is on.
(a) Echo average OFF
(b) Echo average ON
Effect of echo averaging 4. RADAR OPERATION
3. 21
Outputting TLL Data
Target position data can be output to NavNet equipment and shown on their plotter screens with the TTL mark ( X ) 1. If not displayed, press the [HIDE/SHOW] key to display the radar soft keys. Operate the cursor pad to place the cursor on the target whose position you wish to output. Press the TARGET soft key.
. 125nm . 250/SP
H-UP
319. 9°M
TARGET
TRAIL
TLL OUTPUT
ACQ
TARGET INFO
Requires ARP circuit board in Model 1800/1900 series NavNet radar. Not shown otherwise.
RETURN
+
359. 9°R 0. 240nm
TARGET soft keys 4. The TTL mark appears on the plotter screen of the NavNet equipment at the target's position the moment the TLL OUTPUT soft key was pressed. Further, that position is recorded as a waypoint on all NavNet units, under the youngest empty waypoint number on each NavNet unit. Note: The screen of the TLL recipient may be temporarily interrupted when receiving TLL from another NavNet display unit. RADAR OPERATION
3. 22
Guard Alarm
The guard alarm allows the operator to set the desired range and bearing for a guard zone. violate the guard zone, an audio alarm sounds and the offending target blinks to call the operator's attention.
CAUTION
· The alarm should not be relied upon as the sole means for detecting possible collision situations. · A/C SEA, A/C RAIN and GAIN controls should be properly adjusted to be sure the alarm system does not overlook target echoes.
3. 22. 1
Setting a guard alarm zone
To set a guard alarm zone, set the radar to transmit and do the following: 1. Use the cursor pad to set the cursor on the top left corner (or top right corner) of the guard zone you want to set, then press the SET GUARD1 or SET GUARD2 soft key, depending on which guard zone you want to set. Use the cursor pad to set the cursor on the bottom right corner (or top left corner) of the guard zone area, then push the [ENTER] knob. Press RETURN soft key to finish.
. 125nm . 250/SP
H-UP
319. 9°M
ALARM
SET GUARD1
. 125nm . 250/SP
H-UP
319. 9°M
ALARM GUARD 1
SET GUARD1 ERASE GUARD1 SET GUARD2
1
SET GUARD2
2
RETURN
RETURN
MOVE +CURSOR TO ANOTHER CORNER OF GUARD1 AND PUSH KNOB TO SET.
+
317. 2°R 0. 230nm
E ALARM NO B LT
V R M
. 125n . 032nm m
39. 9°R +0. 230nm
(1) Drag cursor to top (or bottom) corner for guard zone and press the SET GUARD1 or SET GUARD2 soft key.
(2) Drag cursor diagonally to bottom (or top) corner for guard zone and press the [ENTER] knob.
How to set a guard alarm zone
3-30
3. [. . . ] 4-5 Marks color. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
O
Offset EBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22, 3-23
Index-3
INDEX
P
Picture advance speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17 PLOTTER SETUP menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 PLOTTR CNTRL soft key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 Port, port services icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13 navigating to . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47 Position offset (GPS Receiver) . . . . . . . . . . . . . . . . . . . . . 5-20 Position smoothing (GPS Receiver) . . . . . . . . . . . . . 5-19 POWER/BRILL key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8, 1-9 Presentation mode plotter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 radar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 Proximity alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57 Pulselength (radar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
switching waypoints in route navigation . . . 2-39
S
SART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO GD-1700
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO GD-1700 will begin.