User manual FURUNO FSV-24 OPERATORS MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO FSV-24. We hope that this FURUNO FSV-24 user guide will be useful to you.


FURUNO FSV-24 OPERATORS MANUAL: Download the complete user guide (2238 Ko)

Manual abstract: user guide FURUNO FSV-24OPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] COLOR SCANNING SONAR FSV-24 Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION : APR. OME-13180 ( HIMA ) FSV-24 *00080916503* *00080916503* *00080916503* *OME13180K00* *OME13180K00* *OME13180K0* SAFETY INSTRUCTIONS DANGER Keep away from moving shaft of the hull unit. A heater can melt the equipment's power cord, which can cause fire or electrical shock. Use the proper fuse. WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. [. . . ] Then, the Vertical 1 display appears, and the vertical bearing marker is displayed in the horizontal display, with "V" at the tip of the marker. If both vertical displays are activated, "1" or "2" is inscribed at the tip of a vertical bearing marker. 3. 4. 2 Auto train You may scan the vertical bearing mark in the sector of OFF, ±12°, ±24° and ±36°. Press and hold down the [AUTO TRAIN] key while pressing the [V1] or [V2] key to choose auto train sector desired. Selected sector appears in large characters for five seconds for your confirmation. The auto train starts. Auto train mark Auto train sector Vertical bearing mark 1 Figure 3-6 Auto train 2. VERTICAL MODE 3. 5 Display Range The [RANGE] control selects the detection range. The range selected is momentarily displayed in large characters at the center of the vertical 1 display. Range is always displayed at the lower left-hand corner of the vertical 1 display. Below are the default ranges (in meters). Range Setting Range 1 200 2 400 3 600 4 1000 5 1600 6 2000 7 3000 8 4000 1. Press the [H/V] key to show the gain and range indications of the vertical mode in yellow. Note: Ranges may be preset as desired on the PRESET, MEMORY CARD menu. For further details, see V-SCAN RANGE on page 8-5. 3. 6 Measuring the Range Operate the trackball to place the trackball mark on the vertical 1 (or vertical 2) display. The range to the location selected is shown at the top left corner. Trackball data Slant range Horizontal range Vertical range Angle to trackball mark from horizontal N A 1547m 1473m 473m 33° V Trackball mark position W E 34°56. 789N 123°45. 678E 500 NAV DATA DISPLAY 1000 1500 500 2000 1000 R 2000m G8 V 12° S Trackball mark Figure 3-7 Measuring range with the trackball 3-6 3. VERTICAL MODE 3. 7 Eliminating Weak Echoes Echoes from targets such as bottom and fish return to the transducer in order of distance to them, and when we compare their intensities at the transducer face, those from nearer targets are generally stronger when their reflecting properties are nearly equal. The sonar operator will be quite inconvenienced if these echoes are directly displayed on the screen, since he can not judge the actual size of the target from the size of echoes displayed on the screen. It compensates for propagation loss of sound in water; amplification of echoes on short range is suppressed and gradually increased as range increases so that similar targets are displayed in the similar intensities irrespective of the ranges to them. The FSV-24 has three TVG functions, NEAR, MEDIUM and FAR, and they mainly compensate for propagation loss on short, middle and long ranges respectively, centered at the ranges as shown in Figure 2-9 on page 2-8. The TVG is also used to suppress unwanted echoes and noise which appear in a certain range area on the screen such as sea surface reflections and cruising noise. Press the [MENU] key to open the menu. MENU TX PULSE LENGTH-H TX POWER-H TVG-NEAR-H TVG-MEDIUM-H TVG-FAR-H AGC-H 2ND AGC-H ECHO AVERAGE-H COLOR-H COLOR RESPONSE-H H-SCAN SETTING. . . QUIT :9 :9 :0 :0 :0 :0 :0 :0 : COLOR 1 : COLOR CURVE 3 Figure 3-8 Menu 2. VERTICAL MODE MENU V-SCAN SETTING TX PULSE LENGTH TVG-NEAR TVG-MEDIUM TVG-FAR NOISE LIMITER AGC ECHO AVERAGE INT REJECT OTHERS. . . :7 :0 :0 :0 :2 :0 :0 :0 QUIT QUIT Figure 3-9 V-SCAN SETTING menu 3. [. . . ] 5-4, 5-5 History mode concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-16 Interference rejector ES1 mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 recalling files from . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 saving files to. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 MENU key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Menu tree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Menus basic operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 DATA DISPLAY menu. . . . . . . . . . . . . . . . . . . . . 8-10 ERASE MARKS menu. . . . . . . . . . . . . . . . . . . . . . 8-2 ES1 SETTING menu . . . . . . . . . . . . . . . . . . . . . . 4-15 ES2 MENU SETTING menu. . . . . . . . . . . 4-17 FISH ALARM & AUDIO menu. . . . . . . . . . . 8-4 H-SCAN SETTING menu . . . . . . . . . . . . . . . 2-34 INITIAL SETTING menu . . . . . . . . . . . . . . . . . . . 8-6 INITIALIZATION menu . . . . . . . . . . . . . . . . . . . 8-16 MAIN menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 MARK DISPLAY menu . . . . . . . . . . . . . . . . . . . . . 8-6 MARK SIZE menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9 NET SHOOTING SETTING menu. . 8-14 NET SONDE SETTING menu . . . . . . . . 8-12 OTHERS menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 PRESET, MEMORY CARD menu . . . . 8-5 STABILIZATION menu . . . . . . . . . . . . . . . . . . . 8-15 TARGET LOCK menu . . . . . . . . . . . . . . . . . . . . 8-14 V-SCAN SETTING menu. . . . . . . . . . . . . . . . 3-13 XMTR DISTANCE menu . . . . . . . . . . . . . . . . 8-13 MODE key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 N Nav data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Net course mark. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31 Net diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14 Net movement plot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8 Net shoot distance unit. . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FSV-24




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FSV-24 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.